Evaluation of methods for predicting axial capacity of jacked-in and driven piles in cohesive soils
(Union of Croatian Civil Engineers and Technicians, 2018)
This paper presents the evaluation of methods for predicting the ultimate axial bearing capacity of single piles based on the cone penetration test (CPT) results, and the evaluation of static methods based on the effective ...
Shear connection with groups of headed studs
(Union of Croatian Civil Engineers and Technicians, 2017)
The behaviour and characteristics of the elements of prefabricated composite steel and concrete structures are determined by behaviour of the longitudinal shear connection. Headed studs in groups are most frequently used ...