Improved flow measurement using EM flat probes in mixed flow conditions
Konferencijski prilog (Objavljena verzija)
Metapodaci
Prikaz svih podataka o dokumentuApstrakt
One of the commonly used approaches, for the flow measurements in sewer systems, are velocity-area methods. Although, it is reported that the velocity sensors operate with high uncertainty, the popularity of these methods stem from the fact that they can be applied in wide range of hydraulic conditions including the mixed flow conditions. Uncertainties are related both to the applied instruments and properties of the measurement site. In order to overcome this issue, additional site-specific calibration procedure for flat EM sensors is presented in this paper. Concept of its application in the engineering practice example are presented.
Ključne reči:
Flow measurement / CFD / electromagnetic sensors / mixed flowIzvor:
Proceeding of 14th IWA / IAHR International Conference on Urban Drainage (ICUD2017), 2017Izdavač:
- ICUD 2017
Finansiranje / projekti:
- Sistemi za odvođenje kišnih voda kao deo urbane i saobraćajne infrastrukture (RS-MESTD-Technological Development (TD or TR)-37010)
Kolekcije
Institucija/grupa
GraFarTY - CONF AU - Ivetić, Damjan AU - Prodanović, Dušan AU - Cvitkovac, Mile PY - 2017 UR - https://grafar.grf.bg.ac.rs/handle/123456789/1735 AB - One of the commonly used approaches, for the flow measurements in sewer systems, are velocity-area methods. Although, it is reported that the velocity sensors operate with high uncertainty, the popularity of these methods stem from the fact that they can be applied in wide range of hydraulic conditions including the mixed flow conditions. Uncertainties are related both to the applied instruments and properties of the measurement site. In order to overcome this issue, additional site-specific calibration procedure for flat EM sensors is presented in this paper. Concept of its application in the engineering practice example are presented. PB - ICUD 2017 C3 - Proceeding of 14th IWA / IAHR International Conference on Urban Drainage (ICUD2017) T1 - Improved flow measurement using EM flat probes in mixed flow conditions UR - https://hdl.handle.net/21.15107/rcub_grafar_1735 ER -
@conference{ author = "Ivetić, Damjan and Prodanović, Dušan and Cvitkovac, Mile", year = "2017", abstract = "One of the commonly used approaches, for the flow measurements in sewer systems, are velocity-area methods. Although, it is reported that the velocity sensors operate with high uncertainty, the popularity of these methods stem from the fact that they can be applied in wide range of hydraulic conditions including the mixed flow conditions. Uncertainties are related both to the applied instruments and properties of the measurement site. In order to overcome this issue, additional site-specific calibration procedure for flat EM sensors is presented in this paper. Concept of its application in the engineering practice example are presented.", publisher = "ICUD 2017", journal = "Proceeding of 14th IWA / IAHR International Conference on Urban Drainage (ICUD2017)", title = "Improved flow measurement using EM flat probes in mixed flow conditions", url = "https://hdl.handle.net/21.15107/rcub_grafar_1735" }
Ivetić, D., Prodanović, D.,& Cvitkovac, M.. (2017). Improved flow measurement using EM flat probes in mixed flow conditions. in Proceeding of 14th IWA / IAHR International Conference on Urban Drainage (ICUD2017) ICUD 2017.. https://hdl.handle.net/21.15107/rcub_grafar_1735
Ivetić D, Prodanović D, Cvitkovac M. Improved flow measurement using EM flat probes in mixed flow conditions. in Proceeding of 14th IWA / IAHR International Conference on Urban Drainage (ICUD2017). 2017;. https://hdl.handle.net/21.15107/rcub_grafar_1735 .
Ivetić, Damjan, Prodanović, Dušan, Cvitkovac, Mile, "Improved flow measurement using EM flat probes in mixed flow conditions" in Proceeding of 14th IWA / IAHR International Conference on Urban Drainage (ICUD2017) (2017), https://hdl.handle.net/21.15107/rcub_grafar_1735 .