Nenadić, Nenad

Link to this page

Authority KeyName Variants
3960aa72-d369-4bc4-97a2-3ef1ffe0e2b5
  • Nenadić, Nenad (2)
Projects

Author's Bibliography

Water quality impact assessment of the River Ibar hydropower system

Jaćimović, Nenad; Kostić, Dušan; Grašić, Slobodan; Nenadić, Nenad

(Jugoslovensko društvo za odvodnjavanje i navodnjavanje, Beograd, 2014)

TY  - JOUR
AU  - Jaćimović, Nenad
AU  - Kostić, Dušan
AU  - Grašić, Slobodan
AU  - Nenadić, Nenad
PY  - 2014
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/575
AB  - Water quality impact assessment of the River Ibar hydropower cascade project is analyzed in this paper, as one of possible aspects of environmental impact assessment. Based on available data provided by authorized institutions, the current state of River Ibar ecological and chemical status is determined in accordance with the methodology prescribed by legislation. The ecological status of the water course between Raska and Kraljevo is rated as moderate, with evaluation considered as reliable. At the same time, the chemical status is rated as good. Quantitative assessment of possible impacts on water quality is conducted by dual approach: 1) application of hydrodynamic model, utilized for analysis of possible thermal regimes in cascade reservoirs, and 2) application of the 'method of analogy' to the existing, well studied reservoir 'Celije', the reservoir with similar morphological characteristics and water quality conditions at the entrance of the system. Results indicate that future cascade reservoir system will represent a number of aquatic ecosystems that will perform as a transitional form between river and lake systems. From the environmental perspective, it is important that thermal stratification of reservoirs during the warm seasons is not expected to be established. Consequently, the eutrophic potential of the River Ibar, based on significant content of macroelements in water, is not expected to be fully realized.
AB  - U radu su analizirani mogući uticaji izgradnje kaskade protočnih hidroelektrana na deonici reke Ibar između Raške i Kraljeva na kvalitet vode, kao jedan od mogućih aspekata uticaja ovih objekata na životnu sredinu. Analizom raspoloživih podataka o kvalitetu vode reke Ibar, najpre je urađena ocena ekološkog i hemijskog statusa. Utvrđeno je da se na posmatranom delu vodotoka ekološki status može ocenitiumerenim, pri čemu se ocena može smatrati pouzdanom, dok je hemijski status ocenjen dobrim. Kvantitativna procena uticaja na kvalitet vode je urađena primenom dvojnog pristupa: 1) primenom hidrodinamičkog modela sistema HE, kojim je simuliran očekivani termički režim u planiranim akumulacijama, i 2) primena 'metode analogije' u odnosu na procese koji su evidentiranina postojećoj akumulaciji 'Ćelije'. Rezultati ukazuju da će planirane akumulacije na Ibru predstavljati niz akvatičnih ekosistema koji će se ponašati i funkcionisati kao prelazni oblik između rečnih i jezerskih sistema. Pri tome, neće biti uslova za formiranje stabilne termičke stratifikacije vode u toplijem delu godine, što će usloviti nemogućnost potpune realizacije eutrofikacionog potencijala, koji nesumnjivo postoji, imajući u vidu sadržaj makroelemenata u vodi reke Ibar u postojećim uslovima.
PB  - Jugoslovensko društvo za odvodnjavanje i navodnjavanje, Beograd
T2  - Vodoprivreda
T1  - Water quality impact assessment of the River Ibar hydropower system
T1  - Analiza uticaja izgradnje sistema HE na Ibru na kvalitet vode
EP  - 178
IS  - 1-6
SP  - 163
VL  - 46
UR  - https://hdl.handle.net/21.15107/rcub_grafar_575
ER  - 
@article{
author = "Jaćimović, Nenad and Kostić, Dušan and Grašić, Slobodan and Nenadić, Nenad",
year = "2014",
abstract = "Water quality impact assessment of the River Ibar hydropower cascade project is analyzed in this paper, as one of possible aspects of environmental impact assessment. Based on available data provided by authorized institutions, the current state of River Ibar ecological and chemical status is determined in accordance with the methodology prescribed by legislation. The ecological status of the water course between Raska and Kraljevo is rated as moderate, with evaluation considered as reliable. At the same time, the chemical status is rated as good. Quantitative assessment of possible impacts on water quality is conducted by dual approach: 1) application of hydrodynamic model, utilized for analysis of possible thermal regimes in cascade reservoirs, and 2) application of the 'method of analogy' to the existing, well studied reservoir 'Celije', the reservoir with similar morphological characteristics and water quality conditions at the entrance of the system. Results indicate that future cascade reservoir system will represent a number of aquatic ecosystems that will perform as a transitional form between river and lake systems. From the environmental perspective, it is important that thermal stratification of reservoirs during the warm seasons is not expected to be established. Consequently, the eutrophic potential of the River Ibar, based on significant content of macroelements in water, is not expected to be fully realized., U radu su analizirani mogući uticaji izgradnje kaskade protočnih hidroelektrana na deonici reke Ibar između Raške i Kraljeva na kvalitet vode, kao jedan od mogućih aspekata uticaja ovih objekata na životnu sredinu. Analizom raspoloživih podataka o kvalitetu vode reke Ibar, najpre je urađena ocena ekološkog i hemijskog statusa. Utvrđeno je da se na posmatranom delu vodotoka ekološki status može ocenitiumerenim, pri čemu se ocena može smatrati pouzdanom, dok je hemijski status ocenjen dobrim. Kvantitativna procena uticaja na kvalitet vode je urađena primenom dvojnog pristupa: 1) primenom hidrodinamičkog modela sistema HE, kojim je simuliran očekivani termički režim u planiranim akumulacijama, i 2) primena 'metode analogije' u odnosu na procese koji su evidentiranina postojećoj akumulaciji 'Ćelije'. Rezultati ukazuju da će planirane akumulacije na Ibru predstavljati niz akvatičnih ekosistema koji će se ponašati i funkcionisati kao prelazni oblik između rečnih i jezerskih sistema. Pri tome, neće biti uslova za formiranje stabilne termičke stratifikacije vode u toplijem delu godine, što će usloviti nemogućnost potpune realizacije eutrofikacionog potencijala, koji nesumnjivo postoji, imajući u vidu sadržaj makroelemenata u vodi reke Ibar u postojećim uslovima.",
publisher = "Jugoslovensko društvo za odvodnjavanje i navodnjavanje, Beograd",
journal = "Vodoprivreda",
title = "Water quality impact assessment of the River Ibar hydropower system, Analiza uticaja izgradnje sistema HE na Ibru na kvalitet vode",
pages = "178-163",
number = "1-6",
volume = "46",
url = "https://hdl.handle.net/21.15107/rcub_grafar_575"
}
Jaćimović, N., Kostić, D., Grašić, S.,& Nenadić, N.. (2014). Water quality impact assessment of the River Ibar hydropower system. in Vodoprivreda
Jugoslovensko društvo za odvodnjavanje i navodnjavanje, Beograd., 46(1-6), 163-178.
https://hdl.handle.net/21.15107/rcub_grafar_575
Jaćimović N, Kostić D, Grašić S, Nenadić N. Water quality impact assessment of the River Ibar hydropower system. in Vodoprivreda. 2014;46(1-6):163-178.
https://hdl.handle.net/21.15107/rcub_grafar_575 .
Jaćimović, Nenad, Kostić, Dušan, Grašić, Slobodan, Nenadić, Nenad, "Water quality impact assessment of the River Ibar hydropower system" in Vodoprivreda, 46, no. 1-6 (2014):163-178,
https://hdl.handle.net/21.15107/rcub_grafar_575 .

Numerical modeling of water temperature changes in reservoir Celije

Nenadić, Nenad; Kostić, Dušan; Jaćimović, Nenad; Naunović, Zorana; Ivetić, Marko

(Udruženje za tehnologiju vode i sanitarno inžinjerstvo, Beograd, 2013)

TY  - JOUR
AU  - Nenadić, Nenad
AU  - Kostić, Dušan
AU  - Jaćimović, Nenad
AU  - Naunović, Zorana
AU  - Ivetić, Marko
PY  - 2013
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/481
AB  - This paper presents the results of measurements and numerical modeling of water temperature changes in reservoir Celije in the period from April to October 2012. Reservoir Celije on the river Rasina, for many years attracts the attention of the general public and researchers, due to the importance of water management and impact of wastewater from the upper part of the basin. Reservoir Celije is a major source of PUC Krusevac Waterworks, but is also the recipient of municipal and industrial wastewater from the municipalities of Brus and Blace. Paper uses a two-dimensional model (CE QUAL W2), with transverse averaged hydrodynamic equations for the velocity and temperature field modeling in the vertical longitudinal plane. Data on the water temperature were collected in the field sampling campaigns, using multi - parameter probes. Model calibration enabled good comparison of measured and calculated temperatures, with average absolute deviation of about 0.7oC. For enhanced model performance, it would be necessary to reduce the uncertainty of the input data, which can be achieved by re- commissioning of the measuring station Ravni (upstream of the reservoir) and setting automatic weather station in the vicinity of the barrier.
AB  - U radu je dat prikaz rezultata merenja i modeliranja sezonskih promena temperature vode u akumulaciji Ćelije u periodu od aprila do oktobra 2012. godine. Akumulacija Ćelije na Rasini, već duži niz godina privlači pažnju šire javnosti i istraživača, obzirom na vodoprivredni značaj i stepen ugroženosti otpadnim vodama iz gornjeg dela sliva. Akumulacija Ćelije je glavno izvorište kruševačkog vodovoda, ali je ujedno i recipijent komunalnih i industrijskih otpadnih voda iz opština Brus i Blace. U radu je korišćen dvodimenzionalni model (CE QUAL W2), sa poprečno osrednjenim hidrodinamičkim jednačinama za modeliranje polja brzina i polja temperatura u vertikalnoj podužnoj ravni. Podaci o temperaturi vode su prikupljeni u kampanjama terenskih merenja, primenom multiparametarskih sondi. Kalibracijom modela, postiglo se dosta dobro poklapanje izmerenih i izračunatih temperatura, sa prosečnim apslutnim odstupanjem od oko 0,7oC. Za unapređen učinak modela, potrebno bi bilo smanjiti neodređenost ulaznih podataka, što bi se postiglo ponovnim puštanjem u pogon merne stanice Ravni (uzvodno od akumulacije) i postavljanjem kompletne automatske meteorološke stanice u blizini pregradnog profila.
PB  - Udruženje za tehnologiju vode i sanitarno inžinjerstvo, Beograd
T2  - Voda i sanitarna tehnika
T1  - Numerical modeling of water temperature changes in reservoir Celije
T1  - Modeliranje sezonskih promena temperature vode akumulacije Ćelije
EP  - 40
IS  - 6
SP  - 31
VL  - 43
UR  - https://hdl.handle.net/21.15107/rcub_grafar_481
ER  - 
@article{
author = "Nenadić, Nenad and Kostić, Dušan and Jaćimović, Nenad and Naunović, Zorana and Ivetić, Marko",
year = "2013",
abstract = "This paper presents the results of measurements and numerical modeling of water temperature changes in reservoir Celije in the period from April to October 2012. Reservoir Celije on the river Rasina, for many years attracts the attention of the general public and researchers, due to the importance of water management and impact of wastewater from the upper part of the basin. Reservoir Celije is a major source of PUC Krusevac Waterworks, but is also the recipient of municipal and industrial wastewater from the municipalities of Brus and Blace. Paper uses a two-dimensional model (CE QUAL W2), with transverse averaged hydrodynamic equations for the velocity and temperature field modeling in the vertical longitudinal plane. Data on the water temperature were collected in the field sampling campaigns, using multi - parameter probes. Model calibration enabled good comparison of measured and calculated temperatures, with average absolute deviation of about 0.7oC. For enhanced model performance, it would be necessary to reduce the uncertainty of the input data, which can be achieved by re- commissioning of the measuring station Ravni (upstream of the reservoir) and setting automatic weather station in the vicinity of the barrier., U radu je dat prikaz rezultata merenja i modeliranja sezonskih promena temperature vode u akumulaciji Ćelije u periodu od aprila do oktobra 2012. godine. Akumulacija Ćelije na Rasini, već duži niz godina privlači pažnju šire javnosti i istraživača, obzirom na vodoprivredni značaj i stepen ugroženosti otpadnim vodama iz gornjeg dela sliva. Akumulacija Ćelije je glavno izvorište kruševačkog vodovoda, ali je ujedno i recipijent komunalnih i industrijskih otpadnih voda iz opština Brus i Blace. U radu je korišćen dvodimenzionalni model (CE QUAL W2), sa poprečno osrednjenim hidrodinamičkim jednačinama za modeliranje polja brzina i polja temperatura u vertikalnoj podužnoj ravni. Podaci o temperaturi vode su prikupljeni u kampanjama terenskih merenja, primenom multiparametarskih sondi. Kalibracijom modela, postiglo se dosta dobro poklapanje izmerenih i izračunatih temperatura, sa prosečnim apslutnim odstupanjem od oko 0,7oC. Za unapređen učinak modela, potrebno bi bilo smanjiti neodređenost ulaznih podataka, što bi se postiglo ponovnim puštanjem u pogon merne stanice Ravni (uzvodno od akumulacije) i postavljanjem kompletne automatske meteorološke stanice u blizini pregradnog profila.",
publisher = "Udruženje za tehnologiju vode i sanitarno inžinjerstvo, Beograd",
journal = "Voda i sanitarna tehnika",
title = "Numerical modeling of water temperature changes in reservoir Celije, Modeliranje sezonskih promena temperature vode akumulacije Ćelije",
pages = "40-31",
number = "6",
volume = "43",
url = "https://hdl.handle.net/21.15107/rcub_grafar_481"
}
Nenadić, N., Kostić, D., Jaćimović, N., Naunović, Z.,& Ivetić, M.. (2013). Numerical modeling of water temperature changes in reservoir Celije. in Voda i sanitarna tehnika
Udruženje za tehnologiju vode i sanitarno inžinjerstvo, Beograd., 43(6), 31-40.
https://hdl.handle.net/21.15107/rcub_grafar_481
Nenadić N, Kostić D, Jaćimović N, Naunović Z, Ivetić M. Numerical modeling of water temperature changes in reservoir Celije. in Voda i sanitarna tehnika. 2013;43(6):31-40.
https://hdl.handle.net/21.15107/rcub_grafar_481 .
Nenadić, Nenad, Kostić, Dušan, Jaćimović, Nenad, Naunović, Zorana, Ivetić, Marko, "Numerical modeling of water temperature changes in reservoir Celije" in Voda i sanitarna tehnika, 43, no. 6 (2013):31-40,
https://hdl.handle.net/21.15107/rcub_grafar_481 .