Experimental investigation of the construction joint in concrete ground floors

Jakovljević, Isidora; Gluhović, Nina; Spremić, Milan; Rajnović, Dušan

(University of Montenegro, Faculty of Civil Engineering, 2024)

TY  - CONF
AU  - Jakovljević, Isidora
AU  - Gluhović, Nina
AU  - Spremić, Milan
AU  - Rajnović, Dušan
PY  - 2024
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/3469
AB  - Ground floors of industrial buildings, fully supported on the ground or piles, are usually made
of several concrete segments connected through free-movement construction joints. These joints
should provide shear load transfer of the slab and minimise its vertical displacements while
allowing slab horizontal movement to prevent damage due to concrete dry shrinkage. The
construction joint “Dilat 08”, consisting of round steel dowels and steel formwork, was
experimentally tested in a laboratory environment to determine its behaviour to shear load. The
experimental double-shear setup consisted of three slabs connecting through the “Dilat 08” join
system, with two side slabs fully supported on the base and the middle slab on which the vertical
loading was applied. Specimens were formed with a gap of 10 mm between adjacent slabs to
simulate the construction joint opening. Two construction joint orientations were investigated
introducing the vertical load to the slab with a steel plate on the edge and to the slab with an
angle profile on the edge. Experimental testing of both specimens resulted in construction joint
failure due to concrete cracking around steel dowels, near the edges of the middle slab. The
investigation confirmed that the joint orientation affects the joint shear response, demonstrating
larger joint resistance when the steel plate is installed in the slab subjected to failure. Although
contributing to the joint bending stiffness before formwork installation on the site, the horizontal
leg of the angle profile decreases the joint resistance. Experimentally obtained joint resistance
was compared to the design values of resistance according to Technical Report 34 and EN 1992-
4, highlighting a considerable difference between the two analytical approaches. The comparison
between the “Dilat 08” and three types of free-movement joints available on the construction
market showed that “Dilat 08” features larger resistance according to Technical Report 34, but
it also weighs more.
PB  - University of Montenegro, Faculty of Civil Engineering
C3  - Proceedings of The 9th International Conference "Civil Engineering – Science and Practice", Kolašin, 5-9th March 2024
T1  - Experimental investigation of the construction joint in concrete ground floors
EP  - 224
SP  - 217
UR  - https://hdl.handle.net/21.15107/rcub_grafar_3469
ER  - 
@conference{
author = "Jakovljević, Isidora and Gluhović, Nina and Spremić, Milan and Rajnović, Dušan",
year = "2024",
abstract = "Ground floors of industrial buildings, fully supported on the ground or piles, are usually made
of several concrete segments connected through free-movement construction joints. These joints
should provide shear load transfer of the slab and minimise its vertical displacements while
allowing slab horizontal movement to prevent damage due to concrete dry shrinkage. The
construction joint “Dilat 08”, consisting of round steel dowels and steel formwork, was
experimentally tested in a laboratory environment to determine its behaviour to shear load. The
experimental double-shear setup consisted of three slabs connecting through the “Dilat 08” join
system, with two side slabs fully supported on the base and the middle slab on which the vertical
loading was applied. Specimens were formed with a gap of 10 mm between adjacent slabs to
simulate the construction joint opening. Two construction joint orientations were investigated
introducing the vertical load to the slab with a steel plate on the edge and to the slab with an
angle profile on the edge. Experimental testing of both specimens resulted in construction joint
failure due to concrete cracking around steel dowels, near the edges of the middle slab. The
investigation confirmed that the joint orientation affects the joint shear response, demonstrating
larger joint resistance when the steel plate is installed in the slab subjected to failure. Although
contributing to the joint bending stiffness before formwork installation on the site, the horizontal
leg of the angle profile decreases the joint resistance. Experimentally obtained joint resistance
was compared to the design values of resistance according to Technical Report 34 and EN 1992-
4, highlighting a considerable difference between the two analytical approaches. The comparison
between the “Dilat 08” and three types of free-movement joints available on the construction
market showed that “Dilat 08” features larger resistance according to Technical Report 34, but
it also weighs more.",
publisher = "University of Montenegro, Faculty of Civil Engineering",
journal = "Proceedings of The 9th International Conference "Civil Engineering – Science and Practice", Kolašin, 5-9th March 2024",
title = "Experimental investigation of the construction joint in concrete ground floors",
pages = "224-217",
url = "https://hdl.handle.net/21.15107/rcub_grafar_3469"
}
Jakovljević, I., Gluhović, N., Spremić, M.,& Rajnović, D.. (2024). Experimental investigation of the construction joint in concrete ground floors. in Proceedings of The 9th International Conference "Civil Engineering – Science and Practice", Kolašin, 5-9th March 2024
University of Montenegro, Faculty of Civil Engineering., 217-224.
https://hdl.handle.net/21.15107/rcub_grafar_3469
Jakovljević I, Gluhović N, Spremić M, Rajnović D. Experimental investigation of the construction joint in concrete ground floors. in Proceedings of The 9th International Conference "Civil Engineering – Science and Practice", Kolašin, 5-9th March 2024. 2024;:217-224.
https://hdl.handle.net/21.15107/rcub_grafar_3469 .
Jakovljević, Isidora, Gluhović, Nina, Spremić, Milan, Rajnović, Dušan, "Experimental investigation of the construction joint in concrete ground floors" in Proceedings of The 9th International Conference "Civil Engineering – Science and Practice", Kolašin, 5-9th March 2024 (2024):217-224,
https://hdl.handle.net/21.15107/rcub_grafar_3469 .

Design procedures for cold-formed stainless steel built-up columns assembled from equal-leg angles

Dobrić, Jelena; Gluhović, Nina; Ivanović, Jovana; Rossi, Barbara

(Elsevier, 2023)

TY  - JOUR
AU  - Dobrić, Jelena
AU  - Gluhović, Nina
AU  - Ivanović, Jovana
AU  - Rossi, Barbara
PY  - 2023
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/3257
AB  - In this paper, the structural behaviour of cold-formed stainless steel (CFSS) built-up T- and cruciform-section columns is studied experimentally and numerically, and the effect of discrete fasteners on their flexural and torsional rigidity is considered. To build the singly symmetrical built-up T-section columns, two equal-leg angle sections made of lean-duplex grade EN 1.4162 were assembled back-to-back. The doubly symmetrical built-up cruciform-section columns were composed of four star-oriented equal-leg angle sections made of austenitic grade EN 1.4301. They were connected using M8 bolts of class 8.8. Two pin-ended built-up T-section columns with length of 1000 mm, and four built-up cruciform-section columns with lengths of 600 mm and 2400 mm with semi-rigid support conditions, were tested under pure axial compression. As observed in the tests, built-up T-section columns experienced flexural-torsional buckling failure, whereas built-up cruciform-section columns failed in torsional buckling mode. Finite element models were validated against the conducted experiments and used to perform a parametric study of the structural behaviour of CFSS built-up T- and cruciform-section columns. The study included the column length, cross-sectional dimensions and bolt spacing as variables. The experimental and numerical data, i.e., the column strengths and failure modes, were compared against the results obtained based on the European and North American Specifications alongside a recent method established for cold-formed carbon steel equivalents and based on the Direct Strength Method (DSM). It is shown that the DSM-based approach predicts the ultimate buckling resistances of the considered built-up columns more accurately than the available codified design methods.
PB  - Elsevier
T2  - Journal of Constructional Steel Research
T1  - Design procedures for cold-formed stainless steel built-up columns assembled from equal-leg angles
VL  - 212
DO  - 10.1016/j.jcsr.2023.108263
ER  - 
@article{
author = "Dobrić, Jelena and Gluhović, Nina and Ivanović, Jovana and Rossi, Barbara",
year = "2023",
abstract = "In this paper, the structural behaviour of cold-formed stainless steel (CFSS) built-up T- and cruciform-section columns is studied experimentally and numerically, and the effect of discrete fasteners on their flexural and torsional rigidity is considered. To build the singly symmetrical built-up T-section columns, two equal-leg angle sections made of lean-duplex grade EN 1.4162 were assembled back-to-back. The doubly symmetrical built-up cruciform-section columns were composed of four star-oriented equal-leg angle sections made of austenitic grade EN 1.4301. They were connected using M8 bolts of class 8.8. Two pin-ended built-up T-section columns with length of 1000 mm, and four built-up cruciform-section columns with lengths of 600 mm and 2400 mm with semi-rigid support conditions, were tested under pure axial compression. As observed in the tests, built-up T-section columns experienced flexural-torsional buckling failure, whereas built-up cruciform-section columns failed in torsional buckling mode. Finite element models were validated against the conducted experiments and used to perform a parametric study of the structural behaviour of CFSS built-up T- and cruciform-section columns. The study included the column length, cross-sectional dimensions and bolt spacing as variables. The experimental and numerical data, i.e., the column strengths and failure modes, were compared against the results obtained based on the European and North American Specifications alongside a recent method established for cold-formed carbon steel equivalents and based on the Direct Strength Method (DSM). It is shown that the DSM-based approach predicts the ultimate buckling resistances of the considered built-up columns more accurately than the available codified design methods.",
publisher = "Elsevier",
journal = "Journal of Constructional Steel Research",
title = "Design procedures for cold-formed stainless steel built-up columns assembled from equal-leg angles",
volume = "212",
doi = "10.1016/j.jcsr.2023.108263"
}
Dobrić, J., Gluhović, N., Ivanović, J.,& Rossi, B.. (2023). Design procedures for cold-formed stainless steel built-up columns assembled from equal-leg angles. in Journal of Constructional Steel Research
Elsevier., 212.
https://doi.org/10.1016/j.jcsr.2023.108263
Dobrić J, Gluhović N, Ivanović J, Rossi B. Design procedures for cold-formed stainless steel built-up columns assembled from equal-leg angles. in Journal of Constructional Steel Research. 2023;212.
doi:10.1016/j.jcsr.2023.108263 .
Dobrić, Jelena, Gluhović, Nina, Ivanović, Jovana, Rossi, Barbara, "Design procedures for cold-formed stainless steel built-up columns assembled from equal-leg angles" in Journal of Constructional Steel Research, 212 (2023),
https://doi.org/10.1016/j.jcsr.2023.108263 . .
2

Numerical characterization of innovative demountable beam-column connections using long bolts

Janković, Neda; Dobrić, Jelena; Gluhović, Nina; Conde, Jorge; Ljubinković, Filip; da Silva, Luís Simões

(2023)

TY  - CONF
AU  - Janković, Neda
AU  - Dobrić, Jelena
AU  - Gluhović, Nina
AU  - Conde, Jorge
AU  - Ljubinković, Filip
AU  - da Silva, Luís Simões
PY  - 2023
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/3378
AB  - Circular design strategies such as adaptivity, detachability, and reusability represent
new challenges and increased demands on the future-proof buildings sector. To contribute to
the circularity and sustainability of the steel construction sector, an innovative solution of beamcolumn
moment-resisting joints with long bolts and short steel elements (links) is proposed,
enabling an extension in the service length of existing steel members. This paper assesses the
influencing connection parameters (e.g. bolt preload, bolt length and diameter, end plate thickness,
etc.) on the moment (flexural) resistance, stiffness, rotation, ductility, and failure modes
of base configurations of these joints.
C3  - Proceedings in Civil Engineering, XIV CONGRESSO DE CONSTRUÇÃO METÁLICA E MISTA, Convento São Francisco, Coimbra – Portugal, 23-24 November, 2023
T1  - Numerical characterization of innovative demountable beam-column connections using long bolts
UR  - https://hdl.handle.net/21.15107/rcub_grafar_3378
ER  - 
@conference{
author = "Janković, Neda and Dobrić, Jelena and Gluhović, Nina and Conde, Jorge and Ljubinković, Filip and da Silva, Luís Simões",
year = "2023",
abstract = "Circular design strategies such as adaptivity, detachability, and reusability represent
new challenges and increased demands on the future-proof buildings sector. To contribute to
the circularity and sustainability of the steel construction sector, an innovative solution of beamcolumn
moment-resisting joints with long bolts and short steel elements (links) is proposed,
enabling an extension in the service length of existing steel members. This paper assesses the
influencing connection parameters (e.g. bolt preload, bolt length and diameter, end plate thickness,
etc.) on the moment (flexural) resistance, stiffness, rotation, ductility, and failure modes
of base configurations of these joints.",
journal = "Proceedings in Civil Engineering, XIV CONGRESSO DE CONSTRUÇÃO METÁLICA E MISTA, Convento São Francisco, Coimbra – Portugal, 23-24 November, 2023",
title = "Numerical characterization of innovative demountable beam-column connections using long bolts",
url = "https://hdl.handle.net/21.15107/rcub_grafar_3378"
}
Janković, N., Dobrić, J., Gluhović, N., Conde, J., Ljubinković, F.,& da Silva, L. S.. (2023). Numerical characterization of innovative demountable beam-column connections using long bolts. in Proceedings in Civil Engineering, XIV CONGRESSO DE CONSTRUÇÃO METÁLICA E MISTA, Convento São Francisco, Coimbra – Portugal, 23-24 November, 2023.
https://hdl.handle.net/21.15107/rcub_grafar_3378
Janković N, Dobrić J, Gluhović N, Conde J, Ljubinković F, da Silva LS. Numerical characterization of innovative demountable beam-column connections using long bolts. in Proceedings in Civil Engineering, XIV CONGRESSO DE CONSTRUÇÃO METÁLICA E MISTA, Convento São Francisco, Coimbra – Portugal, 23-24 November, 2023. 2023;.
https://hdl.handle.net/21.15107/rcub_grafar_3378 .
Janković, Neda, Dobrić, Jelena, Gluhović, Nina, Conde, Jorge, Ljubinković, Filip, da Silva, Luís Simões, "Numerical characterization of innovative demountable beam-column connections using long bolts" in Proceedings in Civil Engineering, XIV CONGRESSO DE CONSTRUÇÃO METÁLICA E MISTA, Convento São Francisco, Coimbra – Portugal, 23-24 November, 2023 (2023),
https://hdl.handle.net/21.15107/rcub_grafar_3378 .

Experimental investigation of influence parameters on cartridge fired pin resistance

Gluhović, Nina; Dobrić, Jelena; Spremić, Milan; Marković, Zlatko

(Ernst & Sohn GmbH, 2023)

TY  - CONF
AU  - Gluhović, Nina
AU  - Dobrić, Jelena
AU  - Spremić, Milan
AU  - Marković, Zlatko
PY  - 2023
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/3219
AB  - Cartridge fired pins, also known as powder actuated fasteners, have a wide application in different construction industry fields, mostly for joints of cold-formed structural elements and profiled steel sheeting, or for installation of shear connectors in composite steel-concrete structures. Installation of cartridge fired pins is mostly governed by high energy introduction from installation device and mechanical fastener to the steel base material, without initial predrilling of holes. Therefore, large plastic deformations of base material are developed through installation procedure, together with various anchorage mechanisms between fastener and base material. This paper presents experimental investigation of most important influence parameters on behaviour and resistance of cartridge fired pins, such as adjusted installation power level on installation device and steel base material strength. Experimental investigation involved X-ENP-21 HVB cartridge fired pins through double-sided shear tests, tension tests with fasteners installed over X-HVB shear connector with two different steel grades (S275 and S355) and two installation power levels (2 and 3.5), and tension tests with fasteners installed over two thicknesses of pro-filed steel sheeting (0.8 mm and 1.0 mm). Cartridge fired pin resistances together with corresponding failure mechanisms were experimentally quantified and presented in this paper.
PB  - Ernst & Sohn GmbH
C3  - ce/papers
T1  - Experimental investigation of influence parameters on cartridge fired pin resistance
EP  - 1398
IS  - 3-4
SP  - 1393
VL  - 6
DO  - 10.1002/cepa.2256
ER  - 
@conference{
author = "Gluhović, Nina and Dobrić, Jelena and Spremić, Milan and Marković, Zlatko",
year = "2023",
abstract = "Cartridge fired pins, also known as powder actuated fasteners, have a wide application in different construction industry fields, mostly for joints of cold-formed structural elements and profiled steel sheeting, or for installation of shear connectors in composite steel-concrete structures. Installation of cartridge fired pins is mostly governed by high energy introduction from installation device and mechanical fastener to the steel base material, without initial predrilling of holes. Therefore, large plastic deformations of base material are developed through installation procedure, together with various anchorage mechanisms between fastener and base material. This paper presents experimental investigation of most important influence parameters on behaviour and resistance of cartridge fired pins, such as adjusted installation power level on installation device and steel base material strength. Experimental investigation involved X-ENP-21 HVB cartridge fired pins through double-sided shear tests, tension tests with fasteners installed over X-HVB shear connector with two different steel grades (S275 and S355) and two installation power levels (2 and 3.5), and tension tests with fasteners installed over two thicknesses of pro-filed steel sheeting (0.8 mm and 1.0 mm). Cartridge fired pin resistances together with corresponding failure mechanisms were experimentally quantified and presented in this paper.",
publisher = "Ernst & Sohn GmbH",
journal = "ce/papers",
title = "Experimental investigation of influence parameters on cartridge fired pin resistance",
pages = "1398-1393",
number = "3-4",
volume = "6",
doi = "10.1002/cepa.2256"
}
Gluhović, N., Dobrić, J., Spremić, M.,& Marković, Z.. (2023). Experimental investigation of influence parameters on cartridge fired pin resistance. in ce/papers
Ernst & Sohn GmbH., 6(3-4), 1393-1398.
https://doi.org/10.1002/cepa.2256
Gluhović N, Dobrić J, Spremić M, Marković Z. Experimental investigation of influence parameters on cartridge fired pin resistance. in ce/papers. 2023;6(3-4):1393-1398.
doi:10.1002/cepa.2256 .
Gluhović, Nina, Dobrić, Jelena, Spremić, Milan, Marković, Zlatko, "Experimental investigation of influence parameters on cartridge fired pin resistance" in ce/papers, 6, no. 3-4 (2023):1393-1398,
https://doi.org/10.1002/cepa.2256 . .

Fire load for performance fire design of car park steel structure

Spremić, Milan; Dinčić, Nemanja; Jakovljević, Isidora; Gluhović, Nina; Dobrić, Jelena

(University of Montenegro, Faculty of Civil Engineering, 2022)

TY  - CONF
AU  - Spremić, Milan
AU  - Dinčić, Nemanja
AU  - Jakovljević, Isidora
AU  - Gluhović, Nina
AU  - Dobrić, Jelena
PY  - 2022
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/3199
AB  - Three advanced fire models for structural design are defined in Eurocode: one-zone model, two-zone model and model based on Computational Fluid Dynamics (CFD). This paper describes the effects on structures exposed to fire, based on the CFD model. The advanced computational fluid dynamics model was used to define the thermal action and temperature of the structural steel elements on the analysed case study object, open multi-storey car park Obilićev Venac in Belgrade. The support structure of the car park is a typical composite floor structure with steel columns. Distance between the columns and the floor beams corresponds to the dimension of one parking slot. The maximum temperature values of steel structural elements that occur during a fire are investigated. Based on the results of the tests available in the literature, CFD fire load models were created. Two different fire loads are used in numerical simulations. The first one is the fire load model based on combustible materials, which simulate the typical modern small car weighing up to one tonne. In the second case, the fire loads model was described with the Heat Release Rate (HRR) curve. Two of the referenced HRR curves defined by the French CTICM and Netherlands TNO Institute are used in CFD models. The discussion in this paper is limited to fire cases with one burning car. The parametric study considered the dimensions and positions of the burner element in the model. The effects of the natural ventilation in the open car park during the fire were also investigated. 
The presented results are from the Research project “Advanced structures design – fire safety guideline for V4” funded by the Višegrad fund. A joint effort of colleagues from Hungary, Czech Republic, Slovakia, Poland and Serbia, produced the project report, which described five different case studies.
PB  - University of Montenegro, Faculty of Civil Engineering
C3  - GNP 2022 Proceedings, The Eighth International Conference Civil Engineering Science & Practice, Kolašin, 8-12th March 2022
T1  - Fire load for performance fire design of car park steel structure
EP  - 380
SP  - 373
UR  - https://hdl.handle.net/21.15107/rcub_grafar_3199
ER  - 
@conference{
author = "Spremić, Milan and Dinčić, Nemanja and Jakovljević, Isidora and Gluhović, Nina and Dobrić, Jelena",
year = "2022",
abstract = "Three advanced fire models for structural design are defined in Eurocode: one-zone model, two-zone model and model based on Computational Fluid Dynamics (CFD). This paper describes the effects on structures exposed to fire, based on the CFD model. The advanced computational fluid dynamics model was used to define the thermal action and temperature of the structural steel elements on the analysed case study object, open multi-storey car park Obilićev Venac in Belgrade. The support structure of the car park is a typical composite floor structure with steel columns. Distance between the columns and the floor beams corresponds to the dimension of one parking slot. The maximum temperature values of steel structural elements that occur during a fire are investigated. Based on the results of the tests available in the literature, CFD fire load models were created. Two different fire loads are used in numerical simulations. The first one is the fire load model based on combustible materials, which simulate the typical modern small car weighing up to one tonne. In the second case, the fire loads model was described with the Heat Release Rate (HRR) curve. Two of the referenced HRR curves defined by the French CTICM and Netherlands TNO Institute are used in CFD models. The discussion in this paper is limited to fire cases with one burning car. The parametric study considered the dimensions and positions of the burner element in the model. The effects of the natural ventilation in the open car park during the fire were also investigated. 
The presented results are from the Research project “Advanced structures design – fire safety guideline for V4” funded by the Višegrad fund. A joint effort of colleagues from Hungary, Czech Republic, Slovakia, Poland and Serbia, produced the project report, which described five different case studies.",
publisher = "University of Montenegro, Faculty of Civil Engineering",
journal = "GNP 2022 Proceedings, The Eighth International Conference Civil Engineering Science & Practice, Kolašin, 8-12th March 2022",
title = "Fire load for performance fire design of car park steel structure",
pages = "380-373",
url = "https://hdl.handle.net/21.15107/rcub_grafar_3199"
}
Spremić, M., Dinčić, N., Jakovljević, I., Gluhović, N.,& Dobrić, J.. (2022). Fire load for performance fire design of car park steel structure. in GNP 2022 Proceedings, The Eighth International Conference Civil Engineering Science & Practice, Kolašin, 8-12th March 2022
University of Montenegro, Faculty of Civil Engineering., 373-380.
https://hdl.handle.net/21.15107/rcub_grafar_3199
Spremić M, Dinčić N, Jakovljević I, Gluhović N, Dobrić J. Fire load for performance fire design of car park steel structure. in GNP 2022 Proceedings, The Eighth International Conference Civil Engineering Science & Practice, Kolašin, 8-12th March 2022. 2022;:373-380.
https://hdl.handle.net/21.15107/rcub_grafar_3199 .
Spremić, Milan, Dinčić, Nemanja, Jakovljević, Isidora, Gluhović, Nina, Dobrić, Jelena, "Fire load for performance fire design of car park steel structure" in GNP 2022 Proceedings, The Eighth International Conference Civil Engineering Science & Practice, Kolašin, 8-12th March 2022 (2022):373-380,
https://hdl.handle.net/21.15107/rcub_grafar_3199 .

Headed studs in profiled steel sheeting: Overview and comments

Jakovljević, Isidora; Spremić, Milan; Gluhović, Nina; Marković, Zlatko

(Društvo građevinskih konstruktera Srbije, Beograd, 2022)

TY  - CONF
AU  - Jakovljević, Isidora
AU  - Spremić, Milan
AU  - Gluhović, Nina
AU  - Marković, Zlatko
PY  - 2022
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/2789
AB  - Headed studs are the most commonly used mechanical shear connectors in composite steel-concrete beams. The behaviour of headed studs differs whether they are applied in solid concrete slabs or composite steel-concrete slabs with profiled steel sheeting. Although design codes provide calculation models for shear resistance of headed studs in profiled steel sheeting, certain weaknesses are attributed to design procedures given in EN 1994-1-1. Alternative design models have been proposed by several researchers. In this paper, novel models are presented and compared through the example of headed studs in different types of profiled steel sheeting.
AB  - Moždanici sa glavom su najčešće primenjivana mehanička spojna sredstava u spregnutim gredama od čelika i betona. Ponašanje moždanika razlikuje se u zavisnosti od toga da li se primenjuju u punim betonskim pločama ili u spregnutim pločama na profilisanom limu. Iako su proračunski modeli za nosivost moždanika u profilisanom limu dati u standardima za projektovanje, važećim proračunskim procedurama datim u EN 1994-1-1 pripisuju se izvesni nedostaci. Iz tog razloga nekoliko istraživača je predložilo alternativne proračunske modele. U radu su prikazani predloženi modeli proračuna i data je uporedna analiza nosivosti moždanika sa glavom u različitim tipovima profilisanog lima.
PB  - Društvo građevinskih konstruktera Srbije, Beograd
C3  - International Congress Proceedings / Association of Structural Engineers of Serbia, 16. Congress
T1  - Headed studs in profiled steel sheeting: Overview and comments
EP  - 561
SP  - 552
UR  - https://hdl.handle.net/21.15107/rcub_grafar_2789
ER  - 
@conference{
author = "Jakovljević, Isidora and Spremić, Milan and Gluhović, Nina and Marković, Zlatko",
year = "2022",
abstract = "Headed studs are the most commonly used mechanical shear connectors in composite steel-concrete beams. The behaviour of headed studs differs whether they are applied in solid concrete slabs or composite steel-concrete slabs with profiled steel sheeting. Although design codes provide calculation models for shear resistance of headed studs in profiled steel sheeting, certain weaknesses are attributed to design procedures given in EN 1994-1-1. Alternative design models have been proposed by several researchers. In this paper, novel models are presented and compared through the example of headed studs in different types of profiled steel sheeting., Moždanici sa glavom su najčešće primenjivana mehanička spojna sredstava u spregnutim gredama od čelika i betona. Ponašanje moždanika razlikuje se u zavisnosti od toga da li se primenjuju u punim betonskim pločama ili u spregnutim pločama na profilisanom limu. Iako su proračunski modeli za nosivost moždanika u profilisanom limu dati u standardima za projektovanje, važećim proračunskim procedurama datim u EN 1994-1-1 pripisuju se izvesni nedostaci. Iz tog razloga nekoliko istraživača je predložilo alternativne proračunske modele. U radu su prikazani predloženi modeli proračuna i data je uporedna analiza nosivosti moždanika sa glavom u različitim tipovima profilisanog lima.",
publisher = "Društvo građevinskih konstruktera Srbije, Beograd",
journal = "International Congress Proceedings / Association of Structural Engineers of Serbia, 16. Congress",
title = "Headed studs in profiled steel sheeting: Overview and comments",
pages = "561-552",
url = "https://hdl.handle.net/21.15107/rcub_grafar_2789"
}
Jakovljević, I., Spremić, M., Gluhović, N.,& Marković, Z.. (2022). Headed studs in profiled steel sheeting: Overview and comments. in International Congress Proceedings / Association of Structural Engineers of Serbia, 16. Congress
Društvo građevinskih konstruktera Srbije, Beograd., 552-561.
https://hdl.handle.net/21.15107/rcub_grafar_2789
Jakovljević I, Spremić M, Gluhović N, Marković Z. Headed studs in profiled steel sheeting: Overview and comments. in International Congress Proceedings / Association of Structural Engineers of Serbia, 16. Congress. 2022;:552-561.
https://hdl.handle.net/21.15107/rcub_grafar_2789 .
Jakovljević, Isidora, Spremić, Milan, Gluhović, Nina, Marković, Zlatko, "Headed studs in profiled steel sheeting: Overview and comments" in International Congress Proceedings / Association of Structural Engineers of Serbia, 16. Congress (2022):552-561,
https://hdl.handle.net/21.15107/rcub_grafar_2789 .

Different Profiled Sheeting Configurations in Steel-Concrete Composite Beams

Jakovljević, Isidora; Spremić, Milan; Marković, Zlatko; Gluhović, Nina

(Ernst & Sohn GmbH, 2022)

TY  - CONF
AU  - Jakovljević, Isidora
AU  - Spremić, Milan
AU  - Marković, Zlatko
AU  - Gluhović, Nina
PY  - 2022
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/2786
AB  - For obtaining shear resistance of a welded headed stud in profiled steel sheeting, EN 1994-1-1:2004 defines reduction factors that should be multiplied with the resistance of a headed stud in a solid concrete slab. Two reduction factors are prescribed, for sheeting ribs that are parallel and transverse to the supporting beam. However, the design code does not recognise cases when the angle between ribs and the beam is in the range between 0° and 90°. This research is focused on the specific case in the steel-concrete composite beam design when the angle between profiled sheeting ribs and the beam is 45°. The experimental investigation has been conducted through push-out tests, comparing the response of the connection with a rib-to-beam angle of 45° and the connection with ribs transverse to the supporting beam. In addition, numerical models based on finite element analysis have been made and validated against experimental data. According to the obtained results, similar failure mechanisms manifested through concrete pull-out failure and separation of the concrete cone are observed in shear connections with rib-to-beam angles of 45° and 90°. An increase in the connection resistance is noticed with the decrease of a rib-to-beam angle.
PB  - Ernst & Sohn GmbH
C3  - ce/papers
T1  - Different Profiled Sheeting Configurations in Steel-Concrete Composite Beams
EP  - 799
IS  - 4
SP  - 795
VL  - 5
DO  - doi/10.1002/cepa.1821
ER  - 
@conference{
author = "Jakovljević, Isidora and Spremić, Milan and Marković, Zlatko and Gluhović, Nina",
year = "2022",
abstract = "For obtaining shear resistance of a welded headed stud in profiled steel sheeting, EN 1994-1-1:2004 defines reduction factors that should be multiplied with the resistance of a headed stud in a solid concrete slab. Two reduction factors are prescribed, for sheeting ribs that are parallel and transverse to the supporting beam. However, the design code does not recognise cases when the angle between ribs and the beam is in the range between 0° and 90°. This research is focused on the specific case in the steel-concrete composite beam design when the angle between profiled sheeting ribs and the beam is 45°. The experimental investigation has been conducted through push-out tests, comparing the response of the connection with a rib-to-beam angle of 45° and the connection with ribs transverse to the supporting beam. In addition, numerical models based on finite element analysis have been made and validated against experimental data. According to the obtained results, similar failure mechanisms manifested through concrete pull-out failure and separation of the concrete cone are observed in shear connections with rib-to-beam angles of 45° and 90°. An increase in the connection resistance is noticed with the decrease of a rib-to-beam angle.",
publisher = "Ernst & Sohn GmbH",
journal = "ce/papers",
title = "Different Profiled Sheeting Configurations in Steel-Concrete Composite Beams",
pages = "799-795",
number = "4",
volume = "5",
doi = "doi/10.1002/cepa.1821"
}
Jakovljević, I., Spremić, M., Marković, Z.,& Gluhović, N.. (2022). Different Profiled Sheeting Configurations in Steel-Concrete Composite Beams. in ce/papers
Ernst & Sohn GmbH., 5(4), 795-799.
https://doi.org/doi/10.1002/cepa.1821
Jakovljević I, Spremić M, Marković Z, Gluhović N. Different Profiled Sheeting Configurations in Steel-Concrete Composite Beams. in ce/papers. 2022;5(4):795-799.
doi:doi/10.1002/cepa.1821 .
Jakovljević, Isidora, Spremić, Milan, Marković, Zlatko, Gluhović, Nina, "Different Profiled Sheeting Configurations in Steel-Concrete Composite Beams" in ce/papers, 5, no. 4 (2022):795-799,
https://doi.org/doi/10.1002/cepa.1821 . .

Stability design criteria for closely spaced built-up stainless steel columns

Dobrić, Jelena; Gluhović, Nina; Marković, Zlatko; Buđevac, Dragan

(Society for Materials and Structures Testing of Serbia, 2021)

TY  - JOUR
AU  - Dobrić, Jelena
AU  - Gluhović, Nina
AU  - Marković, Zlatko
AU  - Buđevac, Dragan
PY  - 2021
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/2623
AB  - This paper aims to develop design recommendations for closely spaced built-up stainless steel columns, based on findings gained in performed research at the University of Belgrade. The research focuses on pin-ended built-up columns formed from two press-braked channel chords oriented back-to-back and addresses their flexural buckling capacity about the minor axis. The impact of overall and local chord slenderness, interconnection stiffness, geometric imperfections and material nonlinearity is evaluated. In order to fully exploit their structural performance, two
separate approaches for the design of built-up columns with welded or bolted interconnections are defined that include different formulas for shear stiffness.
PB  - Society for Materials and Structures Testing of Serbia
PB  - University of Belgrade Faculty of Civil Engineering
PB  - Association of Structural Engineers of Serbia
T2  - Građevinski materijali i konstrukcije Building Materials and Structures
T1  - Stability design criteria for closely spaced built-up stainless steel columns
VL  - 64
DO  - 10.5937/GRMK2104235D
ER  - 
@article{
author = "Dobrić, Jelena and Gluhović, Nina and Marković, Zlatko and Buđevac, Dragan",
year = "2021",
abstract = "This paper aims to develop design recommendations for closely spaced built-up stainless steel columns, based on findings gained in performed research at the University of Belgrade. The research focuses on pin-ended built-up columns formed from two press-braked channel chords oriented back-to-back and addresses their flexural buckling capacity about the minor axis. The impact of overall and local chord slenderness, interconnection stiffness, geometric imperfections and material nonlinearity is evaluated. In order to fully exploit their structural performance, two
separate approaches for the design of built-up columns with welded or bolted interconnections are defined that include different formulas for shear stiffness.",
publisher = "Society for Materials and Structures Testing of Serbia, University of Belgrade Faculty of Civil Engineering, Association of Structural Engineers of Serbia",
journal = "Građevinski materijali i konstrukcije Building Materials and Structures",
title = "Stability design criteria for closely spaced built-up stainless steel columns",
volume = "64",
doi = "10.5937/GRMK2104235D"
}
Dobrić, J., Gluhović, N., Marković, Z.,& Buđevac, D.. (2021). Stability design criteria for closely spaced built-up stainless steel columns. in Građevinski materijali i konstrukcije Building Materials and Structures
Society for Materials and Structures Testing of Serbia., 64.
https://doi.org/10.5937/GRMK2104235D
Dobrić J, Gluhović N, Marković Z, Buđevac D. Stability design criteria for closely spaced built-up stainless steel columns. in Građevinski materijali i konstrukcije Building Materials and Structures. 2021;64.
doi:10.5937/GRMK2104235D .
Dobrić, Jelena, Gluhović, Nina, Marković, Zlatko, Buđevac, Dragan, "Stability design criteria for closely spaced built-up stainless steel columns" in Građevinski materijali i konstrukcije Building Materials and Structures, 64 (2021),
https://doi.org/10.5937/GRMK2104235D . .
1

The Behaviour of Shear Anchors with Different Grout Properties

Spremić, Milan; Gluhović, Nina; Jakovljević, Isidora; Marković, Zlatko

(Ernst&Sohn, 2021)

TY  - CONF
AU  - Spremić, Milan
AU  - Gluhović, Nina
AU  - Jakovljević, Isidora
AU  - Marković, Zlatko
PY  - 2021
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/2488
AB  - During the assembling of a steel structure with anchors, grout should be used in connections be-
tween steel elements and a reinforced concrete support element. In horizontal and vertical joints, 
grout is used as a good construction practice for solving geometric tolerance problems. Grout can 
be used with cast-in anchors or post-installed anchors. However, the relation between anchor 
shear resistance and characteristic grout compressive strength is not described in detail in tech-
nical regulations. The behaviour of a connection considering achieved slip tolerances should 
match the boundary conditions set in the global analysis. In the support joint, grout properties 
could influence the value of the slip between a steel part and a concrete part of the joint.  Slip value 
could be significant for the relevant design cases featuring the interaction of shear force and ten-
sion force. In this paper, results of the push-out test conducted on anchors are presented. Based 
on the experimental test, the finite element analysis was performed to investigate the shear con-
nection behaviour. According to the preliminary results, it can be concluded that a grout strength 
and a grout thickness influence the connection response when serviceability loads are applied, alt-
hough they do not influence the ultimate load bearing capacity of anchors. In some cases, using 
the contemporary solutions of high strength grout materials, the slip between steel and concrete 
parts in the connection could be reduced.
PB  - Ernst&Sohn
C3  - CE/Papers
T1  - The Behaviour of Shear Anchors with Different  Grout Properties
EP  - 950
IS  - 2-4
SP  - 945
VL  - 4
DO  - https://doi.org/10.1002/cepa.1382
ER  - 
@conference{
author = "Spremić, Milan and Gluhović, Nina and Jakovljević, Isidora and Marković, Zlatko",
year = "2021",
abstract = "During the assembling of a steel structure with anchors, grout should be used in connections be-
tween steel elements and a reinforced concrete support element. In horizontal and vertical joints, 
grout is used as a good construction practice for solving geometric tolerance problems. Grout can 
be used with cast-in anchors or post-installed anchors. However, the relation between anchor 
shear resistance and characteristic grout compressive strength is not described in detail in tech-
nical regulations. The behaviour of a connection considering achieved slip tolerances should 
match the boundary conditions set in the global analysis. In the support joint, grout properties 
could influence the value of the slip between a steel part and a concrete part of the joint.  Slip value 
could be significant for the relevant design cases featuring the interaction of shear force and ten-
sion force. In this paper, results of the push-out test conducted on anchors are presented. Based 
on the experimental test, the finite element analysis was performed to investigate the shear con-
nection behaviour. According to the preliminary results, it can be concluded that a grout strength 
and a grout thickness influence the connection response when serviceability loads are applied, alt-
hough they do not influence the ultimate load bearing capacity of anchors. In some cases, using 
the contemporary solutions of high strength grout materials, the slip between steel and concrete 
parts in the connection could be reduced.",
publisher = "Ernst&Sohn",
journal = "CE/Papers",
title = "The Behaviour of Shear Anchors with Different  Grout Properties",
pages = "950-945",
number = "2-4",
volume = "4",
doi = "https://doi.org/10.1002/cepa.1382"
}
Spremić, M., Gluhović, N., Jakovljević, I.,& Marković, Z.. (2021). The Behaviour of Shear Anchors with Different  Grout Properties. in CE/Papers
Ernst&Sohn., 4(2-4), 945-950.
https://doi.org/https://doi.org/10.1002/cepa.1382
Spremić M, Gluhović N, Jakovljević I, Marković Z. The Behaviour of Shear Anchors with Different  Grout Properties. in CE/Papers. 2021;4(2-4):945-950.
doi:https://doi.org/10.1002/cepa.1382 .
Spremić, Milan, Gluhović, Nina, Jakovljević, Isidora, Marković, Zlatko, "The Behaviour of Shear Anchors with Different  Grout Properties" in CE/Papers, 4, no. 2-4 (2021):945-950,
https://doi.org/https://doi.org/10.1002/cepa.1382 . .

Numerical parametric study on steel-concrete composite floor beams vibrations due to pedestrian traffic

Gluhović, Nina; Marković, Zlatko; Spremić, Milan

(Society for Materials and Structures Testing of Serbia, 2021)

TY  - JOUR
AU  - Gluhović, Nina
AU  - Marković, Zlatko
AU  - Spremić, Milan
PY  - 2021
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/2350
AB  - Human perception of floor vibrations and uncompromised serviceability of equipment are two most important acceptability criteria considering floor vibrations. While verification of deflection is a simple and well-known procedure in structures’ design for serviceability limit state, the fulfilment of floor vibrations acceptability criteria are presented in different standards in the form of various calculation procedures. Results achieved through those calculation procedures are presented in the form of various classification of floor structures. Classification of composite floor structures due to vibrations is inconsistent considering different calculation procedures. Comparison of various calculation procedures for the definition of composite floor vibrations is presented in this paper. In addition, a parametric analysis is performed on the wide range of steel-concrete composite floor structures, through analysis of various composite floor layouts and a wide range of imposed
loads values. The analysis of the relation between deflection, vertical vibrations and accelerations of steel-concrete composite floor beams is presented in this paper. The results of the parametric analysis are given through direct relation between deflections of composite beams and achieved floor class for the fulfilment of vibrations acceptability criteria due to the pedestrian walking.
PB  - Society for Materials and Structures Testing of Serbia
PB  - University of Belgrade Faculty of Civil Engineering
PB  - Association of Structural Engineers of Serbia
T2  - Građevinski materijali i konstrukcije Building Materials and Structures
T1  - Numerical parametric study on steel-concrete composite floor beams vibrations due to pedestrian traffic
EP  - 58
IS  - 1
SP  - 45
VL  - 64
DO  - 10.5937/GRMK2101045G
ER  - 
@article{
author = "Gluhović, Nina and Marković, Zlatko and Spremić, Milan",
year = "2021",
abstract = "Human perception of floor vibrations and uncompromised serviceability of equipment are two most important acceptability criteria considering floor vibrations. While verification of deflection is a simple and well-known procedure in structures’ design for serviceability limit state, the fulfilment of floor vibrations acceptability criteria are presented in different standards in the form of various calculation procedures. Results achieved through those calculation procedures are presented in the form of various classification of floor structures. Classification of composite floor structures due to vibrations is inconsistent considering different calculation procedures. Comparison of various calculation procedures for the definition of composite floor vibrations is presented in this paper. In addition, a parametric analysis is performed on the wide range of steel-concrete composite floor structures, through analysis of various composite floor layouts and a wide range of imposed
loads values. The analysis of the relation between deflection, vertical vibrations and accelerations of steel-concrete composite floor beams is presented in this paper. The results of the parametric analysis are given through direct relation between deflections of composite beams and achieved floor class for the fulfilment of vibrations acceptability criteria due to the pedestrian walking.",
publisher = "Society for Materials and Structures Testing of Serbia, University of Belgrade Faculty of Civil Engineering, Association of Structural Engineers of Serbia",
journal = "Građevinski materijali i konstrukcije Building Materials and Structures",
title = "Numerical parametric study on steel-concrete composite floor beams vibrations due to pedestrian traffic",
pages = "58-45",
number = "1",
volume = "64",
doi = "10.5937/GRMK2101045G"
}
Gluhović, N., Marković, Z.,& Spremić, M.. (2021). Numerical parametric study on steel-concrete composite floor beams vibrations due to pedestrian traffic. in Građevinski materijali i konstrukcije Building Materials and Structures
Society for Materials and Structures Testing of Serbia., 64(1), 45-58.
https://doi.org/10.5937/GRMK2101045G
Gluhović N, Marković Z, Spremić M. Numerical parametric study on steel-concrete composite floor beams vibrations due to pedestrian traffic. in Građevinski materijali i konstrukcije Building Materials and Structures. 2021;64(1):45-58.
doi:10.5937/GRMK2101045G .
Gluhović, Nina, Marković, Zlatko, Spremić, Milan, "Numerical parametric study on steel-concrete composite floor beams vibrations due to pedestrian traffic" in Građevinski materijali i konstrukcije Building Materials and Structures, 64, no. 1 (2021):45-58,
https://doi.org/10.5937/GRMK2101045G . .

Grout effect on the behaviour of the anchor shear connection

Spremić, Milan; Gluhović, Nina; Jakovljević, Isidora; Marković, Zlatko

(Univerzitet u Beogradu, Građevinski fakultet, 2021)

TY  - CONF
AU  - Spremić, Milan
AU  - Gluhović, Nina
AU  - Jakovljević, Isidora
AU  - Marković, Zlatko
PY  - 2021
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/2359
AB  - Prefabricated construction and requirements for reusing the particular structural element, request the application of a support joint realized with anchors. Besides demountability, the connection detail realized with anchors needs to satisfy all support conditions adopted during the structure design. This paper describes the behaviour of anchor shear connection. The connection slip was analysed concerning the grout material properties and the grout thickness. The parametric study was performed using Abaqus software to define the relationship between grout properties and thickness and the slip deformation for load levels corresponding to serviceability limit states.
PB  - Univerzitet u Beogradu, Građevinski fakultet
PB  - Društvo građevinskih konstruktera Srbije
C3  - ASES International symposium proceedings
T1  - Grout effect on the behaviour of the anchor shear connection
UR  - https://hdl.handle.net/21.15107/rcub_grafar_2359
ER  - 
@conference{
author = "Spremić, Milan and Gluhović, Nina and Jakovljević, Isidora and Marković, Zlatko",
year = "2021",
abstract = "Prefabricated construction and requirements for reusing the particular structural element, request the application of a support joint realized with anchors. Besides demountability, the connection detail realized with anchors needs to satisfy all support conditions adopted during the structure design. This paper describes the behaviour of anchor shear connection. The connection slip was analysed concerning the grout material properties and the grout thickness. The parametric study was performed using Abaqus software to define the relationship between grout properties and thickness and the slip deformation for load levels corresponding to serviceability limit states.",
publisher = "Univerzitet u Beogradu, Građevinski fakultet, Društvo građevinskih konstruktera Srbije",
journal = "ASES International symposium proceedings",
title = "Grout effect on the behaviour of the anchor shear connection",
url = "https://hdl.handle.net/21.15107/rcub_grafar_2359"
}
Spremić, M., Gluhović, N., Jakovljević, I.,& Marković, Z.. (2021). Grout effect on the behaviour of the anchor shear connection. in ASES International symposium proceedings
Univerzitet u Beogradu, Građevinski fakultet..
https://hdl.handle.net/21.15107/rcub_grafar_2359
Spremić M, Gluhović N, Jakovljević I, Marković Z. Grout effect on the behaviour of the anchor shear connection. in ASES International symposium proceedings. 2021;.
https://hdl.handle.net/21.15107/rcub_grafar_2359 .
Spremić, Milan, Gluhović, Nina, Jakovljević, Isidora, Marković, Zlatko, "Grout effect on the behaviour of the anchor shear connection" in ASES International symposium proceedings (2021),
https://hdl.handle.net/21.15107/rcub_grafar_2359 .

Behaviour of shear connections realised by connectors fastened with cartridge fired pins

Gluhović, Nina

(Univerzitet u Beogradu, Građevinski fakultet, 2021)

TY  - CONF
AU  - Gluhović, Nina
PY  - 2021
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/2358
AB  - Composite action between steel beams and prefabricated or solid concrete slabs can be achieved with various types of shear connectors which differ considering their main properties, installation time and required equipment at the construction site. Mechanically fastened shear connectors represent an alternative solution to the traditionally used welded headed studs or bolted shear connectors. X-HVB shear connectors fastened with two X-ENP-21 HVB cartridge fired pins are their main representative. The behaviour of shear connection realised by X-HVB shear connectors is investigated through experiments and numerical analysis of both parts: shear connectors and cartridge fired pins. Main achievements of this investigation are presented in this paper and should lead to a better understanding of X-HVB shear connectors behaviour and extension of the currently small basis of available experimental results.
PB  - Univerzitet u Beogradu, Građevinski fakultet
PB  - Društvo građevinskih konstruktera Srbije
C3  - ASES International symposium proceedings
T1  - Behaviour of shear connections realised by connectors fastened with cartridge fired pins
UR  - https://hdl.handle.net/21.15107/rcub_grafar_2358
ER  - 
@conference{
author = "Gluhović, Nina",
year = "2021",
abstract = "Composite action between steel beams and prefabricated or solid concrete slabs can be achieved with various types of shear connectors which differ considering their main properties, installation time and required equipment at the construction site. Mechanically fastened shear connectors represent an alternative solution to the traditionally used welded headed studs or bolted shear connectors. X-HVB shear connectors fastened with two X-ENP-21 HVB cartridge fired pins are their main representative. The behaviour of shear connection realised by X-HVB shear connectors is investigated through experiments and numerical analysis of both parts: shear connectors and cartridge fired pins. Main achievements of this investigation are presented in this paper and should lead to a better understanding of X-HVB shear connectors behaviour and extension of the currently small basis of available experimental results.",
publisher = "Univerzitet u Beogradu, Građevinski fakultet, Društvo građevinskih konstruktera Srbije",
journal = "ASES International symposium proceedings",
title = "Behaviour of shear connections realised by connectors fastened with cartridge fired pins",
url = "https://hdl.handle.net/21.15107/rcub_grafar_2358"
}
Gluhović, N.. (2021). Behaviour of shear connections realised by connectors fastened with cartridge fired pins. in ASES International symposium proceedings
Univerzitet u Beogradu, Građevinski fakultet..
https://hdl.handle.net/21.15107/rcub_grafar_2358
Gluhović N. Behaviour of shear connections realised by connectors fastened with cartridge fired pins. in ASES International symposium proceedings. 2021;.
https://hdl.handle.net/21.15107/rcub_grafar_2358 .
Gluhović, Nina, "Behaviour of shear connections realised by connectors fastened with cartridge fired pins" in ASES International symposium proceedings (2021),
https://hdl.handle.net/21.15107/rcub_grafar_2358 .

Comparison of wind actions according to Eurocode and previous regulations

Marković, Zlatko; Dobrić, Jelena; Gluhović, Nina

(SS Cyril and Methodius Faculty of Civil Engineering, 2020)

TY  - JOUR
AU  - Marković, Zlatko
AU  - Dobrić, Jelena
AU  - Gluhović, Nina
PY  - 2020
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/2179
AB  - European norms for civil engineering structures, well known as Eurocodes, are set of
highly harmonized codes regarding structural issues. Main rules and recommendations for
calculation of wind actions on structures are given in EN 1991-1-4 which is the basic document. Also, some advanced analysis regarding wind actions on towers and masts are given in EN 1993-3-1, with the intention to be transferred in the basic document in the later phase. This paper contains a short presentation of the main rules and recommendations for wind action analysis and their comparison with previous regulations JUS (SRPS). The main focus of the paper is on wind action on buildings and comparative numerical example is also given. Some experiences and conclusions from the process of Serbian National Annex preparation are also presented.
PB  - SS Cyril and Methodius Faculty of Civil Engineering
T2  - Scientific Journal of Civil Engineering
T1  - Comparison of wind actions according to Eurocode and previous regulations
VL  - 9
UR  - https://hdl.handle.net/21.15107/rcub_grafar_2179
ER  - 
@article{
author = "Marković, Zlatko and Dobrić, Jelena and Gluhović, Nina",
year = "2020",
abstract = "European norms for civil engineering structures, well known as Eurocodes, are set of
highly harmonized codes regarding structural issues. Main rules and recommendations for
calculation of wind actions on structures are given in EN 1991-1-4 which is the basic document. Also, some advanced analysis regarding wind actions on towers and masts are given in EN 1993-3-1, with the intention to be transferred in the basic document in the later phase. This paper contains a short presentation of the main rules and recommendations for wind action analysis and their comparison with previous regulations JUS (SRPS). The main focus of the paper is on wind action on buildings and comparative numerical example is also given. Some experiences and conclusions from the process of Serbian National Annex preparation are also presented.",
publisher = "SS Cyril and Methodius Faculty of Civil Engineering",
journal = "Scientific Journal of Civil Engineering",
title = "Comparison of wind actions according to Eurocode and previous regulations",
volume = "9",
url = "https://hdl.handle.net/21.15107/rcub_grafar_2179"
}
Marković, Z., Dobrić, J.,& Gluhović, N.. (2020). Comparison of wind actions according to Eurocode and previous regulations. in Scientific Journal of Civil Engineering
SS Cyril and Methodius Faculty of Civil Engineering., 9.
https://hdl.handle.net/21.15107/rcub_grafar_2179
Marković Z, Dobrić J, Gluhović N. Comparison of wind actions according to Eurocode and previous regulations. in Scientific Journal of Civil Engineering. 2020;9.
https://hdl.handle.net/21.15107/rcub_grafar_2179 .
Marković, Zlatko, Dobrić, Jelena, Gluhović, Nina, "Comparison of wind actions according to Eurocode and previous regulations" in Scientific Journal of Civil Engineering, 9 (2020),
https://hdl.handle.net/21.15107/rcub_grafar_2179 .

Mechanically fastened shear connectors in prefabricated concrete slabs – experimental analysis

Gluhović, Nina; Marković, Zlatko; Spremić, Milan; Pavlović, Marko

(Techno Press, 2020)

TY  - JOUR
AU  - Gluhović, Nina
AU  - Marković, Zlatko
AU  - Spremić, Milan
AU  - Pavlović, Marko
PY  - 2020
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/2077
AB  - Nowadays, in prefabricated composite construction, composite action between steel beam and concrete slab is often achieved with positioning of shear connectors in envisaged openings of concrete slabs. Prefabricated concrete slabs are used for composite steel-concrete buildings and bridges, both for the construction of new structures and for renovation of existing ones, significantly reducing construction time. Development of different types of shear connectors represent alternative solution to the traditionally used headed studs, considering their shear resistance, stiffness and ductility. New types of shear connectors tend to reduce the construction time and overall construction cost. Mechanically fastened shear connectors represent a viable alternative to headed studs, considering their fast installation process and shear resistance. X-HVB shear connectors are attached to the steel beam with two cartridge fired pins. The first step towards extensive implementation of X-HVB shear connectors in composite construction is to understand their behaviour through experimental investigation. Results of the push-out tests, in accordance to
Eurocode 4, with X-HVB 110 shear connectors positioned in envisaged openings of prefabricated concrete slabs are presented in this paper. The experimental investigation comprised three different specimen’s layout. Group arrangement of X-HVB shear connectors in envisaged openings included specimens with minimal recommended distances and specimens with reduced distances between connectors in both directions. Influence of different installation procedures on overall behaviour of the connection is presented, as well as the orientation of shear connectors relative to the shear force direction. Influence of variations is characterized in terms of failure mechanisms, shear resistance and ductility.
PB  - Techno Press
T2  - Steel and Composite Structures
T1  - Mechanically fastened shear connectors in prefabricated concrete slabs – experimental analysis
VL  - 36
DO  - 10.12989/scs.2020.36.4.369
ER  - 
@article{
author = "Gluhović, Nina and Marković, Zlatko and Spremić, Milan and Pavlović, Marko",
year = "2020",
abstract = "Nowadays, in prefabricated composite construction, composite action between steel beam and concrete slab is often achieved with positioning of shear connectors in envisaged openings of concrete slabs. Prefabricated concrete slabs are used for composite steel-concrete buildings and bridges, both for the construction of new structures and for renovation of existing ones, significantly reducing construction time. Development of different types of shear connectors represent alternative solution to the traditionally used headed studs, considering their shear resistance, stiffness and ductility. New types of shear connectors tend to reduce the construction time and overall construction cost. Mechanically fastened shear connectors represent a viable alternative to headed studs, considering their fast installation process and shear resistance. X-HVB shear connectors are attached to the steel beam with two cartridge fired pins. The first step towards extensive implementation of X-HVB shear connectors in composite construction is to understand their behaviour through experimental investigation. Results of the push-out tests, in accordance to
Eurocode 4, with X-HVB 110 shear connectors positioned in envisaged openings of prefabricated concrete slabs are presented in this paper. The experimental investigation comprised three different specimen’s layout. Group arrangement of X-HVB shear connectors in envisaged openings included specimens with minimal recommended distances and specimens with reduced distances between connectors in both directions. Influence of different installation procedures on overall behaviour of the connection is presented, as well as the orientation of shear connectors relative to the shear force direction. Influence of variations is characterized in terms of failure mechanisms, shear resistance and ductility.",
publisher = "Techno Press",
journal = "Steel and Composite Structures",
title = "Mechanically fastened shear connectors in prefabricated concrete slabs – experimental analysis",
volume = "36",
doi = "10.12989/scs.2020.36.4.369"
}
Gluhović, N., Marković, Z., Spremić, M.,& Pavlović, M.. (2020). Mechanically fastened shear connectors in prefabricated concrete slabs – experimental analysis. in Steel and Composite Structures
Techno Press., 36.
https://doi.org/10.12989/scs.2020.36.4.369
Gluhović N, Marković Z, Spremić M, Pavlović M. Mechanically fastened shear connectors in prefabricated concrete slabs – experimental analysis. in Steel and Composite Structures. 2020;36.
doi:10.12989/scs.2020.36.4.369 .
Gluhović, Nina, Marković, Zlatko, Spremić, Milan, Pavlović, Marko, "Mechanically fastened shear connectors in prefabricated concrete slabs – experimental analysis" in Steel and Composite Structures, 36 (2020),
https://doi.org/10.12989/scs.2020.36.4.369 . .
3

Behaviour of thin-walled cylindrical and conical shells: Carbon vs. stainless steel

Kostadinović Vranešević, Kristina; Gluhović, Nina; Dobrić, Jelena; Spremić, Milan

(Društvo za ispitivanje i istraživanje materijala i konstrukcija Srbije, Beograd, 2019)

TY  - JOUR
AU  - Kostadinović Vranešević, Kristina
AU  - Gluhović, Nina
AU  - Dobrić, Jelena
AU  - Spremić, Milan
PY  - 2019
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/995
AB  - Thin-walled cylindrical and conical shells represent one of the most complex structural elements considering their behaviour and susceptibility to buckling. A brief theoretical review including the presentation of different currently available design recommendations is given in this paper. Influence of initial imperfections on nonlinear behaviour of cylindrical and conical shells is also presented through numerical analysis. Shells with different wall thicknesses and different values of initial imperfections, but constant length and diameter of shell are analysed. Numerical analysis includes materially and geometrically nonlinear analysis of cylindrical and conical shells, using experimentally obtained stress-strain relation of carbon steel and stainless steel. Material nonlinearity and initial geometrical imperfections resulted in significantly lower buckling resistance of shells.
AB  - Tanke kružne cilindrične i konusne ljuske predstavljaju jedan od složenijih konstruktivnih elemenata u pogledu ponašanja i osetljivosti na izbočavanje. U radu je dat kratak teorijski osvrt, s prikazom različitih, trenutno dostupnih, proračunskih preporuka. Prikazana je numerička analiza uticaja početnih imperfekcija na nelinearno ponašanje kružnih cilindričnih i konusnih ljuski. Analizirane su ljuske različite debljine zida, s konstantnim vrednostima dužine i prečnika ljuske, kao i s različitim vrednostima početnih imperfekcija. Analiza obuhvata uticaj materijalne i geometrijske nelinearnosti na ponašanje ljuski od ugljeničnog i nerđajućeg čelika, uključujući eksperimentalne krive napon-dilatacija. U radu je pokazano da materijalna nelineranost i početna geometrijska imperfekcija dovode do značajnog pada nosivosti na izbočavanje ljuski.
PB  - Društvo za ispitivanje i istraživanje materijala i konstrukcija Srbije, Beograd
T2  - Građevinski materijali i konstrukcije
T1  - Behaviour of thin-walled cylindrical and conical shells: Carbon vs. stainless steel
T1  - Poređenje ponašanja tankih cilindričnih i konusnih ljuski od ugljeničnog i nerđajućeg čelika
EP  - 42
IS  - 1
SP  - 27
VL  - 62
DO  - 10.5937/GRMK1901027K
ER  - 
@article{
author = "Kostadinović Vranešević, Kristina and Gluhović, Nina and Dobrić, Jelena and Spremić, Milan",
year = "2019",
abstract = "Thin-walled cylindrical and conical shells represent one of the most complex structural elements considering their behaviour and susceptibility to buckling. A brief theoretical review including the presentation of different currently available design recommendations is given in this paper. Influence of initial imperfections on nonlinear behaviour of cylindrical and conical shells is also presented through numerical analysis. Shells with different wall thicknesses and different values of initial imperfections, but constant length and diameter of shell are analysed. Numerical analysis includes materially and geometrically nonlinear analysis of cylindrical and conical shells, using experimentally obtained stress-strain relation of carbon steel and stainless steel. Material nonlinearity and initial geometrical imperfections resulted in significantly lower buckling resistance of shells., Tanke kružne cilindrične i konusne ljuske predstavljaju jedan od složenijih konstruktivnih elemenata u pogledu ponašanja i osetljivosti na izbočavanje. U radu je dat kratak teorijski osvrt, s prikazom različitih, trenutno dostupnih, proračunskih preporuka. Prikazana je numerička analiza uticaja početnih imperfekcija na nelinearno ponašanje kružnih cilindričnih i konusnih ljuski. Analizirane su ljuske različite debljine zida, s konstantnim vrednostima dužine i prečnika ljuske, kao i s različitim vrednostima početnih imperfekcija. Analiza obuhvata uticaj materijalne i geometrijske nelinearnosti na ponašanje ljuski od ugljeničnog i nerđajućeg čelika, uključujući eksperimentalne krive napon-dilatacija. U radu je pokazano da materijalna nelineranost i početna geometrijska imperfekcija dovode do značajnog pada nosivosti na izbočavanje ljuski.",
publisher = "Društvo za ispitivanje i istraživanje materijala i konstrukcija Srbije, Beograd",
journal = "Građevinski materijali i konstrukcije",
title = "Behaviour of thin-walled cylindrical and conical shells: Carbon vs. stainless steel, Poređenje ponašanja tankih cilindričnih i konusnih ljuski od ugljeničnog i nerđajućeg čelika",
pages = "42-27",
number = "1",
volume = "62",
doi = "10.5937/GRMK1901027K"
}
Kostadinović Vranešević, K., Gluhović, N., Dobrić, J.,& Spremić, M.. (2019). Behaviour of thin-walled cylindrical and conical shells: Carbon vs. stainless steel. in Građevinski materijali i konstrukcije
Društvo za ispitivanje i istraživanje materijala i konstrukcija Srbije, Beograd., 62(1), 27-42.
https://doi.org/10.5937/GRMK1901027K
Kostadinović Vranešević K, Gluhović N, Dobrić J, Spremić M. Behaviour of thin-walled cylindrical and conical shells: Carbon vs. stainless steel. in Građevinski materijali i konstrukcije. 2019;62(1):27-42.
doi:10.5937/GRMK1901027K .
Kostadinović Vranešević, Kristina, Gluhović, Nina, Dobrić, Jelena, Spremić, Milan, "Behaviour of thin-walled cylindrical and conical shells: Carbon vs. stainless steel" in Građevinski materijali i konstrukcije, 62, no. 1 (2019):27-42,
https://doi.org/10.5937/GRMK1901027K . .

Primena mehanički spojenih sredstava za sprezanje u spregnutim konstrukcijama

Gluhović, Nina; Marković, Zlatko; Spremić, Milan; Pavlović, Marko

(Savez građevinskih inženjera Srbije, 2019)

TY  - JOUR
AU  - Gluhović, Nina
AU  - Marković, Zlatko
AU  - Spremić, Milan
AU  - Pavlović, Marko
PY  - 2019
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/2104
AB  - Savremeni trendovi u građevinarstvu u oblasti spregnutih konstrukcija od čelika i betona najčešće se ogledaju u povećanim zahtevima za ubrzanom gradnjom, razvojem novih vrsta sredstava za sprezanje i prefabrikovanom gradnjom. Mehanički spojena sredstva za sprezanje predstavljaju alternativu tradicionalno korištenim zavarenim moždanicima sa glavom. Veza ovakvih sredstava za sprezanje sa čeličnim nosačima ostvaruje se pomoću različitih mehaničkih spojnih sredstava koji se ugrađuju procesom eksplozivnog upucavanja. U literaturi se ova mehanička spojna sredstva najčešće označavaju kao ekseri sa eksplozivnim upucavanjem. Mehanički spojena sredstva za sprezanje čine jedinstven sistem formiran od samog sredstva za sprezanje, odnosno moždanika i mehaničkog spojnog sredstva, odnosno eksera. Stoga je njihovo ponašanje u spregnutim konstrukcijama u direktnoj vezi sa ponašanjem eksera sa eksplozivnim upucavanjem. Za razliku od zavarenih moždanika sa glavom ili zavrtenjeva kao sredstava za sprezanje koji se često koriste u zgradarstvu, ponašanje mehanički spojenih sredstava za sprezanje u literaturi nije još uvek detaljno objašnjeno. U ovom radu dat je prikaz X-HVB moždanika kao najpoznatijeg predstavnika mehanički spojenih sredstava za sprezanje. Objašnjeno je njihovo ponašanje u spregnutim konstrukcijama i prikazane su osnovne karakteristike eksera sa eksplozivnim upucavanjem.
PB  - Savez građevinskih inženjera Srbije
T2  - Građevinski kalendar
T1  - Primena mehanički spojenih sredstava za sprezanje u spregnutim konstrukcijama
VL  - 51
UR  - https://hdl.handle.net/21.15107/rcub_grafar_2104
ER  - 
@article{
author = "Gluhović, Nina and Marković, Zlatko and Spremić, Milan and Pavlović, Marko",
year = "2019",
abstract = "Savremeni trendovi u građevinarstvu u oblasti spregnutih konstrukcija od čelika i betona najčešće se ogledaju u povećanim zahtevima za ubrzanom gradnjom, razvojem novih vrsta sredstava za sprezanje i prefabrikovanom gradnjom. Mehanički spojena sredstva za sprezanje predstavljaju alternativu tradicionalno korištenim zavarenim moždanicima sa glavom. Veza ovakvih sredstava za sprezanje sa čeličnim nosačima ostvaruje se pomoću različitih mehaničkih spojnih sredstava koji se ugrađuju procesom eksplozivnog upucavanja. U literaturi se ova mehanička spojna sredstva najčešće označavaju kao ekseri sa eksplozivnim upucavanjem. Mehanički spojena sredstva za sprezanje čine jedinstven sistem formiran od samog sredstva za sprezanje, odnosno moždanika i mehaničkog spojnog sredstva, odnosno eksera. Stoga je njihovo ponašanje u spregnutim konstrukcijama u direktnoj vezi sa ponašanjem eksera sa eksplozivnim upucavanjem. Za razliku od zavarenih moždanika sa glavom ili zavrtenjeva kao sredstava za sprezanje koji se često koriste u zgradarstvu, ponašanje mehanički spojenih sredstava za sprezanje u literaturi nije još uvek detaljno objašnjeno. U ovom radu dat je prikaz X-HVB moždanika kao najpoznatijeg predstavnika mehanički spojenih sredstava za sprezanje. Objašnjeno je njihovo ponašanje u spregnutim konstrukcijama i prikazane su osnovne karakteristike eksera sa eksplozivnim upucavanjem.",
publisher = "Savez građevinskih inženjera Srbije",
journal = "Građevinski kalendar",
title = "Primena mehanički spojenih sredstava za sprezanje u spregnutim konstrukcijama",
volume = "51",
url = "https://hdl.handle.net/21.15107/rcub_grafar_2104"
}
Gluhović, N., Marković, Z., Spremić, M.,& Pavlović, M.. (2019). Primena mehanički spojenih sredstava za sprezanje u spregnutim konstrukcijama. in Građevinski kalendar
Savez građevinskih inženjera Srbije., 51.
https://hdl.handle.net/21.15107/rcub_grafar_2104
Gluhović N, Marković Z, Spremić M, Pavlović M. Primena mehanički spojenih sredstava za sprezanje u spregnutim konstrukcijama. in Građevinski kalendar. 2019;51.
https://hdl.handle.net/21.15107/rcub_grafar_2104 .
Gluhović, Nina, Marković, Zlatko, Spremić, Milan, Pavlović, Marko, "Primena mehanički spojenih sredstava za sprezanje u spregnutim konstrukcijama" in Građevinski kalendar, 51 (2019),
https://hdl.handle.net/21.15107/rcub_grafar_2104 .

Behaviour of shear connections realised by connectors fastened with cartridge fired pins: doctoral dissertation

Gluhović, Nina

(Универзитет у Београду, Грађевински факултет, 2019)

TY  - THES
AU  - Gluhović, Nina
PY  - 2019
UR  - http://eteze.bg.ac.rs/application/showtheses?thesesId=7408
UR  - https://fedorabg.bg.ac.rs/fedora/get/o:21813/bdef:Content/download
UR  - http://vbs.rs/scripts/cobiss?command=DISPLAY&base=70036&RID=513822610
UR  - http://nardus.mpn.gov.rs/123456789/12269
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/1971
AB  - New demands towards fast construction resulted in development of different types of prefabricated concrete slabs and shear connectors. Composite action between steel beam and concrete slabs can be achieved with group positioning of shear connectors in envisaged openings of prefabricated concrete slabs. The aim of presented investigation is to promote application of mechanically fastened shear connectors in prefabricated concrete slabs. X-HVB 110 shear connectors fastened to the steel base material with X-ENP-21 HVB cartridge fired pins are used in experimental and numerical analysis presented in this thesis. Presented investigation should improve understanding of X-HVB shear connectors behaviour which is currently based on their application in solid or composite concrete slabs. Also, this investigation should result in extension of currently small basis of experimental results, which are mostly part of the technical reports and are considered as proprietary. Feasibility study presented in this work highlighted the importance of further investigation of X-HVB shear connectors in group arrangement, at distances smaller than minimal recommended, in order to satisfy current recommendations for minimal partial shear connection degree in composite floor structures with profiled steel sheeting. Detail examination of X-HVB 110 shear connectors positioned in envisaged openings of prefabricated composite slabs is performed. The experiment aims at understanding the effects of the spacing between shear connectors, orientation of shear connectors relative to the shear force direction and installation power level used for installation of cartridge fired pins, when they are used for prefabricated composite construction. In order to generate all structural performance data, this investigation included experimental investigation of cartridge fired pins performed through shear and tension tests. Extensive finite element analysis is conducted in this research in order to develop and calibrate FE models of push-out test specimens of X-HVB 110 shear connectors, and shear and tension tests of cartridge fired pins, based on the results of presented experimental research. The novelty in the FE modelling approach developed in this study is phenomenological simulation of installation procedure of cartridge fired pins resulting in preloading of the pins and interaction withiiithe base material. Numerical FE models are developed through extensive calibration of main parameters which are introduced in FE simulation of firing the pins in tension tests and further sensitivity study. Parametric study of push-out FE models is performed for X-HVB 110 shear connectors through variation of concrete and steel base material properties. Main failure mechanisms which are obtained through experimental investigation of X-HVB 110 shear connectors in prefabricated concrete slabs are related to deformation capacity and pull-out of cartridge fired pins from the steel base material. Developed FE models of push-out test series matched the failure mechanisms obtained through experimental investigation. Pull-out of cartridge fired pins in FE models is defined by equivalent compressive contact stresses and friction at the interface between the base material and pins modelled as separate parts. This resembles the physical mechanism of the load transfer of cartridge fired pins and is a recommended modelling procedure as it gives good agreement with experimental results. Presented FE modelling approach of installation procedure of cartridge fired pins highlights the clamping of the fastener in steel base material as the most dominant anchorage mechanism. Prediction models for pull-out resistance of cartridge fired pins loaded in tension and shear resistance of X-HVB shear connectors are proposed based on the presented results of experimental and numerical investigation.
AB  - Савремени трендови у грађевинарству се најчешће огледају у повећаним захтевима за убрзаном градњом, што је утицало на развој нових вртса префабрикованих бетонских плоча и средстава за спрезање. Спрезање префабрикованих бетонских плоча и челичних гредних носача најчешће се постиже постављањем можданика у отворе у бетонској плочи, који су за то предвиђени у процесу префабрикације. Предмет научног истраживања је понашање смичућих спојева остварених помоћу X-HVB можданика у префабрикованим бетонским плочама. X-HVB 110 можданици повезани су са челичним профилима уз помоћ два X-ENP-21 HVB механичка спојна средства (ексера) експлозивним упуцавањем. Приказано испитивање треба да допринесе бољем разумевању понашања X-HVB можданика у смичућим спојевима, које је тренутно засновано на испитивањима у пуним и спрегнутим бетонским плочама на профилисаним лимовима. Такође, испитивање треба да допринесе проширењу тренутно мале базе експерименталних испитивања, којa су највећим делом садржанa у техничким извештајима који нису лако доступни истраживачима. Упоредна анализа носивости заварених можданика са главом и X-HVB можданика у спрегнутим плочама са профилисаним лимом, презентована у овом раду, нагласила је потребу за додатним испитивањима ове врсте можданика када су они груписани на растојањима која су мања од минимално препоручених, како би се задовољиле тренутне препоруке у погледу минималног процента парцијалног смичућег споја. Детаљно експериментално испитивање X-HVB 110 можданика постављених у отворе префабрикованих бетонских плоча спорведно је у овом раду. Испитивање је обухватило утицај положаја и међусобног растојања можданика у односу на правац смичуће силе као и различите јачине уградње ексера. У циљу јасног сагледавања понашања ове врсте можданика, експеримeнтално испитивање ескера је спроведено кроз тестове смицања и затезања. Нумерички модели базирани на методи коначних елемената развијени су за потребе симулирања смичућих спојева са X-HVB 110 можданицима као и ескера са експлозивним упуцавањем који су оптерећени на смицање и затезање иvкалибрисани су према резултатима експерименталног испитивања. Симулација уградње ексера са експлозивним упуцавањем која је дефинисана кроз нумеричке моделе резултовала је преднапрезањем ексера и дефинисањем посебних услова интеракције између ексера и основног материјала. Нумерички модели су развијени кроз опсежну калибрацију основних параметара који су кориштени за дефинисање процеса уградње и накнадно су анализирани кроз студију осетљивости спроведну на моделима са X-HVB 110 можданицима. Параметарска анализа спроведена је на моделима смичућих спојева X-HVB 110 можданика кроз промену механичких својстава бетона и основног челичног материјала. Основни модели лома који су се појавили кроз експериментално испитивање повезани су са деформацијом ексера и њиховим извлачењем из основног челичног материјала. Развијени нумерички модели смичућих спојева са X-HVB 110 можданицима потврдили су овакве видове лома. Носивост на извачење ексера из основног челичног материјала дефинисана је кроз еквивалентни напон притиска и коефицијент трења који је развијен на контактној површини између ексера и основног челичног материјала. Овакав начин нумеричког моделирања процеса уградње ескера показао је добро слагање са резултатима експерименталног испитивања и наглашава укљештење ексера у основни челични материјал као најдоминантнији механизам анкеровања. Предиктивни изрази за носивост ексера на извлачење и носивост X-HVB можданика у смичућим спојевима дефинисани су у овом раду на основу презентованог експерименталног и нумеричког испитивања.
PB  - Универзитет у Београду, Грађевински факултет
T2  - Универзитет у Београду
T1  - Behaviour of shear connections realised by connectors fastened with cartridge fired pins: doctoral dissertation
UR  - https://hdl.handle.net/21.15107/rcub_nardus_12269
ER  - 
@phdthesis{
author = "Gluhović, Nina",
year = "2019",
abstract = "New demands towards fast construction resulted in development of different types of prefabricated concrete slabs and shear connectors. Composite action between steel beam and concrete slabs can be achieved with group positioning of shear connectors in envisaged openings of prefabricated concrete slabs. The aim of presented investigation is to promote application of mechanically fastened shear connectors in prefabricated concrete slabs. X-HVB 110 shear connectors fastened to the steel base material with X-ENP-21 HVB cartridge fired pins are used in experimental and numerical analysis presented in this thesis. Presented investigation should improve understanding of X-HVB shear connectors behaviour which is currently based on their application in solid or composite concrete slabs. Also, this investigation should result in extension of currently small basis of experimental results, which are mostly part of the technical reports and are considered as proprietary. Feasibility study presented in this work highlighted the importance of further investigation of X-HVB shear connectors in group arrangement, at distances smaller than minimal recommended, in order to satisfy current recommendations for minimal partial shear connection degree in composite floor structures with profiled steel sheeting. Detail examination of X-HVB 110 shear connectors positioned in envisaged openings of prefabricated composite slabs is performed. The experiment aims at understanding the effects of the spacing between shear connectors, orientation of shear connectors relative to the shear force direction and installation power level used for installation of cartridge fired pins, when they are used for prefabricated composite construction. In order to generate all structural performance data, this investigation included experimental investigation of cartridge fired pins performed through shear and tension tests. Extensive finite element analysis is conducted in this research in order to develop and calibrate FE models of push-out test specimens of X-HVB 110 shear connectors, and shear and tension tests of cartridge fired pins, based on the results of presented experimental research. The novelty in the FE modelling approach developed in this study is phenomenological simulation of installation procedure of cartridge fired pins resulting in preloading of the pins and interaction withiiithe base material. Numerical FE models are developed through extensive calibration of main parameters which are introduced in FE simulation of firing the pins in tension tests and further sensitivity study. Parametric study of push-out FE models is performed for X-HVB 110 shear connectors through variation of concrete and steel base material properties. Main failure mechanisms which are obtained through experimental investigation of X-HVB 110 shear connectors in prefabricated concrete slabs are related to deformation capacity and pull-out of cartridge fired pins from the steel base material. Developed FE models of push-out test series matched the failure mechanisms obtained through experimental investigation. Pull-out of cartridge fired pins in FE models is defined by equivalent compressive contact stresses and friction at the interface between the base material and pins modelled as separate parts. This resembles the physical mechanism of the load transfer of cartridge fired pins and is a recommended modelling procedure as it gives good agreement with experimental results. Presented FE modelling approach of installation procedure of cartridge fired pins highlights the clamping of the fastener in steel base material as the most dominant anchorage mechanism. Prediction models for pull-out resistance of cartridge fired pins loaded in tension and shear resistance of X-HVB shear connectors are proposed based on the presented results of experimental and numerical investigation., Савремени трендови у грађевинарству се најчешће огледају у повећаним захтевима за убрзаном градњом, што је утицало на развој нових вртса префабрикованих бетонских плоча и средстава за спрезање. Спрезање префабрикованих бетонских плоча и челичних гредних носача најчешће се постиже постављањем можданика у отворе у бетонској плочи, који су за то предвиђени у процесу префабрикације. Предмет научног истраживања је понашање смичућих спојева остварених помоћу X-HVB можданика у префабрикованим бетонским плочама. X-HVB 110 можданици повезани су са челичним профилима уз помоћ два X-ENP-21 HVB механичка спојна средства (ексера) експлозивним упуцавањем. Приказано испитивање треба да допринесе бољем разумевању понашања X-HVB можданика у смичућим спојевима, које је тренутно засновано на испитивањима у пуним и спрегнутим бетонским плочама на профилисаним лимовима. Такође, испитивање треба да допринесе проширењу тренутно мале базе експерименталних испитивања, којa су највећим делом садржанa у техничким извештајима који нису лако доступни истраживачима. Упоредна анализа носивости заварених можданика са главом и X-HVB можданика у спрегнутим плочама са профилисаним лимом, презентована у овом раду, нагласила је потребу за додатним испитивањима ове врсте можданика када су они груписани на растојањима која су мања од минимално препоручених, како би се задовољиле тренутне препоруке у погледу минималног процента парцијалног смичућег споја. Детаљно експериментално испитивање X-HVB 110 можданика постављених у отворе префабрикованих бетонских плоча спорведно је у овом раду. Испитивање је обухватило утицај положаја и међусобног растојања можданика у односу на правац смичуће силе као и различите јачине уградње ексера. У циљу јасног сагледавања понашања ове врсте можданика, експеримeнтално испитивање ескера је спроведено кроз тестове смицања и затезања. Нумерички модели базирани на методи коначних елемената развијени су за потребе симулирања смичућих спојева са X-HVB 110 можданицима као и ескера са експлозивним упуцавањем који су оптерећени на смицање и затезање иvкалибрисани су према резултатима експерименталног испитивања. Симулација уградње ексера са експлозивним упуцавањем која је дефинисана кроз нумеричке моделе резултовала је преднапрезањем ексера и дефинисањем посебних услова интеракције између ексера и основног материјала. Нумерички модели су развијени кроз опсежну калибрацију основних параметара који су кориштени за дефинисање процеса уградње и накнадно су анализирани кроз студију осетљивости спроведну на моделима са X-HVB 110 можданицима. Параметарска анализа спроведена је на моделима смичућих спојева X-HVB 110 можданика кроз промену механичких својстава бетона и основног челичног материјала. Основни модели лома који су се појавили кроз експериментално испитивање повезани су са деформацијом ексера и њиховим извлачењем из основног челичног материјала. Развијени нумерички модели смичућих спојева са X-HVB 110 можданицима потврдили су овакве видове лома. Носивост на извачење ексера из основног челичног материјала дефинисана је кроз еквивалентни напон притиска и коефицијент трења који је развијен на контактној површини између ексера и основног челичног материјала. Овакав начин нумеричког моделирања процеса уградње ескера показао је добро слагање са резултатима експерименталног испитивања и наглашава укљештење ексера у основни челични материјал као најдоминантнији механизам анкеровања. Предиктивни изрази за носивост ексера на извлачење и носивост X-HVB можданика у смичућим спојевима дефинисани су у овом раду на основу презентованог експерименталног и нумеричког испитивања.",
publisher = "Универзитет у Београду, Грађевински факултет",
journal = "Универзитет у Београду",
title = "Behaviour of shear connections realised by connectors fastened with cartridge fired pins: doctoral dissertation",
url = "https://hdl.handle.net/21.15107/rcub_nardus_12269"
}
Gluhović, N.. (2019). Behaviour of shear connections realised by connectors fastened with cartridge fired pins: doctoral dissertation. in Универзитет у Београду
Универзитет у Београду, Грађевински факултет..
https://hdl.handle.net/21.15107/rcub_nardus_12269
Gluhović N. Behaviour of shear connections realised by connectors fastened with cartridge fired pins: doctoral dissertation. in Универзитет у Београду. 2019;.
https://hdl.handle.net/21.15107/rcub_nardus_12269 .
Gluhović, Nina, "Behaviour of shear connections realised by connectors fastened with cartridge fired pins: doctoral dissertation" in Универзитет у Београду (2019),
https://hdl.handle.net/21.15107/rcub_nardus_12269 .

Ductility of different types of shear connectors – experimental and numerical analysis

Gluhović, Nina; Spremić, Milan; Milosavljević, Branko; Marković, Zlatko; Dobrić, Jelena

(Czech Technical University in Prague, 2019)

TY  - CONF
AU  - Gluhović, Nina
AU  - Spremić, Milan
AU  - Milosavljević, Branko
AU  - Marković, Zlatko
AU  - Dobrić, Jelena
PY  - 2019
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/1969
AB  - Different types of shear connectors, which are used for achievement of steel-concrete
composite action, have been developed during decades. Their suitability for various range
of structures and loadings is determined by shear resistance, ductility of shear connectors, obtained failure mechanisms and fatigue resistance. Headed studs are widely used for composite
construction of buildings and bridges. Perforated shear connectors, mechanically fastened shear
connectors or bolted shear connectors with mechanical couplers are alternative solution for
achievement of composite action between steel and concrete. Results of experimental and numerical  analysis of these types of shear connectors are used for comparative analysis and presented in this paper. Presented analysis included comparison of stiffness and different failure mechanisms for these types of shear connections, with focus on the ductility at different load levels. Besides, results are compared with recommendation given in EN 1994-1-1 for ductile shear connectors.
PB  - Czech Technical University in Prague
C3  - The international colloquium on stability and ductility of steel structures
T1  - Ductility of different types of shear connectors – experimental and numerical analysis
UR  - https://hdl.handle.net/21.15107/rcub_grafar_1969
ER  - 
@conference{
author = "Gluhović, Nina and Spremić, Milan and Milosavljević, Branko and Marković, Zlatko and Dobrić, Jelena",
year = "2019",
abstract = "Different types of shear connectors, which are used for achievement of steel-concrete
composite action, have been developed during decades. Their suitability for various range
of structures and loadings is determined by shear resistance, ductility of shear connectors, obtained failure mechanisms and fatigue resistance. Headed studs are widely used for composite
construction of buildings and bridges. Perforated shear connectors, mechanically fastened shear
connectors or bolted shear connectors with mechanical couplers are alternative solution for
achievement of composite action between steel and concrete. Results of experimental and numerical  analysis of these types of shear connectors are used for comparative analysis and presented in this paper. Presented analysis included comparison of stiffness and different failure mechanisms for these types of shear connections, with focus on the ductility at different load levels. Besides, results are compared with recommendation given in EN 1994-1-1 for ductile shear connectors.",
publisher = "Czech Technical University in Prague",
journal = "The international colloquium on stability and ductility of steel structures",
title = "Ductility of different types of shear connectors – experimental and numerical analysis",
url = "https://hdl.handle.net/21.15107/rcub_grafar_1969"
}
Gluhović, N., Spremić, M., Milosavljević, B., Marković, Z.,& Dobrić, J.. (2019). Ductility of different types of shear connectors – experimental and numerical analysis. in The international colloquium on stability and ductility of steel structures
Czech Technical University in Prague..
https://hdl.handle.net/21.15107/rcub_grafar_1969
Gluhović N, Spremić M, Milosavljević B, Marković Z, Dobrić J. Ductility of different types of shear connectors – experimental and numerical analysis. in The international colloquium on stability and ductility of steel structures. 2019;.
https://hdl.handle.net/21.15107/rcub_grafar_1969 .
Gluhović, Nina, Spremić, Milan, Milosavljević, Branko, Marković, Zlatko, Dobrić, Jelena, "Ductility of different types of shear connectors – experimental and numerical analysis" in The international colloquium on stability and ductility of steel structures (2019),
https://hdl.handle.net/21.15107/rcub_grafar_1969 .

Numerical study of vibrations induced by horizontal-axis wind turbine on a steel building

Gluhović, Nina; Spremić, Milan; Pavlović, Marko; Marković, Zlatko

(2019)

TY  - JOUR
AU  - Gluhović, Nina
AU  - Spremić, Milan
AU  - Pavlović, Marko
AU  - Marković, Zlatko
PY  - 2019
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/1646
AB  - One of the most important acceptance issues regarding the implementation of small-scale wind turbines in urban environments is related to human comfort. Turbine-induced vibrations can have a large influence on small-scale turbine implementation for urban wind harvesting. A typical five-storey steel-framed office building with a roof-mounted, horizontal-axis wind turbine was numerically analysed. The aim of the work was to investigate the increase in vibration after the installation of the turbine. A comparison was made between floor vibrations caused by wind action on the building only and by wind action on the building and turbine combined. The results were then compared with requirements given in various design codes. The main outcome of the analysis is that the installation of the turbine did not compromise the building's serviceability.
T2  - Proceedings of the Institution of Civil Engineers - Structures and Buildings
T1  - Numerical study of vibrations induced by horizontal-axis wind turbine on a steel building
EP  - 598
IS  - 8
SP  - 590
VL  - 172
DO  - 10.1680/jstbu.17.00168
ER  - 
@article{
author = "Gluhović, Nina and Spremić, Milan and Pavlović, Marko and Marković, Zlatko",
year = "2019",
abstract = "One of the most important acceptance issues regarding the implementation of small-scale wind turbines in urban environments is related to human comfort. Turbine-induced vibrations can have a large influence on small-scale turbine implementation for urban wind harvesting. A typical five-storey steel-framed office building with a roof-mounted, horizontal-axis wind turbine was numerically analysed. The aim of the work was to investigate the increase in vibration after the installation of the turbine. A comparison was made between floor vibrations caused by wind action on the building only and by wind action on the building and turbine combined. The results were then compared with requirements given in various design codes. The main outcome of the analysis is that the installation of the turbine did not compromise the building's serviceability.",
journal = "Proceedings of the Institution of Civil Engineers - Structures and Buildings",
title = "Numerical study of vibrations induced by horizontal-axis wind turbine on a steel building",
pages = "598-590",
number = "8",
volume = "172",
doi = "10.1680/jstbu.17.00168"
}
Gluhović, N., Spremić, M., Pavlović, M.,& Marković, Z.. (2019). Numerical study of vibrations induced by horizontal-axis wind turbine on a steel building. in Proceedings of the Institution of Civil Engineers - Structures and Buildings, 172(8), 590-598.
https://doi.org/10.1680/jstbu.17.00168
Gluhović N, Spremić M, Pavlović M, Marković Z. Numerical study of vibrations induced by horizontal-axis wind turbine on a steel building. in Proceedings of the Institution of Civil Engineers - Structures and Buildings. 2019;172(8):590-598.
doi:10.1680/jstbu.17.00168 .
Gluhović, Nina, Spremić, Milan, Pavlović, Marko, Marković, Zlatko, "Numerical study of vibrations induced by horizontal-axis wind turbine on a steel building" in Proceedings of the Institution of Civil Engineers - Structures and Buildings, 172, no. 8 (2019):590-598,
https://doi.org/10.1680/jstbu.17.00168 . .
1
1
1

Non-linear lateral buckling analysis of aluminium alloy channel beams

Ivanović, Nikola; Dobrić, Jelena; Spremić, Milan; Gluhović, Nina; Milovanović, Jovana

(Društvo građevinskih konstruktera Srbije, Beograd, 2018)

TY  - CONF
AU  - Ivanović, Nikola
AU  - Dobrić, Jelena
AU  - Spremić, Milan
AU  - Gluhović, Nina
AU  - Milovanović, Jovana
PY  - 2018
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/1634
AB  - This research paper presents the comparative analysis of lateral-torsional buckling resistance of structural aluminium alloy members, accounting for the effects of initial geometrical imperfections. The results of non-linear numerical analysis, conducted using ABAQUS software, are compared with the results obtained by utilizing the procedure for calculation of LTB resistance suggested by EN 1999-1-1. The purpose of the analysis is the assessment of accuracy of the above-mentioned code-prescribed design method using the real Al channelsection members with initial imperfections on which the load does not act in the shear centre.
PB  - Društvo građevinskih konstruktera Srbije, Beograd
C3  - ASES International congress proceedings / Association of Structural Engineers of Serbia, 15th Congress, September 6-8th, 2018, Zlatibor
T1  - Non-linear lateral buckling analysis of aluminium alloy channel beams
EP  - 464
SP  - 456
UR  - https://hdl.handle.net/21.15107/rcub_grafar_1634
ER  - 
@conference{
author = "Ivanović, Nikola and Dobrić, Jelena and Spremić, Milan and Gluhović, Nina and Milovanović, Jovana",
year = "2018",
abstract = "This research paper presents the comparative analysis of lateral-torsional buckling resistance of structural aluminium alloy members, accounting for the effects of initial geometrical imperfections. The results of non-linear numerical analysis, conducted using ABAQUS software, are compared with the results obtained by utilizing the procedure for calculation of LTB resistance suggested by EN 1999-1-1. The purpose of the analysis is the assessment of accuracy of the above-mentioned code-prescribed design method using the real Al channelsection members with initial imperfections on which the load does not act in the shear centre.",
publisher = "Društvo građevinskih konstruktera Srbije, Beograd",
journal = "ASES International congress proceedings / Association of Structural Engineers of Serbia, 15th Congress, September 6-8th, 2018, Zlatibor",
title = "Non-linear lateral buckling analysis of aluminium alloy channel beams",
pages = "464-456",
url = "https://hdl.handle.net/21.15107/rcub_grafar_1634"
}
Ivanović, N., Dobrić, J., Spremić, M., Gluhović, N.,& Milovanović, J.. (2018). Non-linear lateral buckling analysis of aluminium alloy channel beams. in ASES International congress proceedings / Association of Structural Engineers of Serbia, 15th Congress, September 6-8th, 2018, Zlatibor
Društvo građevinskih konstruktera Srbije, Beograd., 456-464.
https://hdl.handle.net/21.15107/rcub_grafar_1634
Ivanović N, Dobrić J, Spremić M, Gluhović N, Milovanović J. Non-linear lateral buckling analysis of aluminium alloy channel beams. in ASES International congress proceedings / Association of Structural Engineers of Serbia, 15th Congress, September 6-8th, 2018, Zlatibor. 2018;:456-464.
https://hdl.handle.net/21.15107/rcub_grafar_1634 .
Ivanović, Nikola, Dobrić, Jelena, Spremić, Milan, Gluhović, Nina, Milovanović, Jovana, "Non-linear lateral buckling analysis of aluminium alloy channel beams" in ASES International congress proceedings / Association of Structural Engineers of Serbia, 15th Congress, September 6-8th, 2018, Zlatibor (2018):456-464,
https://hdl.handle.net/21.15107/rcub_grafar_1634 .

Design of pedestrian bridge according to Eurocode 9

Kondić, Stefan; Dobrić, Jelena; Gluhović, Nina

(Društvo građevinskih konstruktera Srbije, Beograd, 2018)

TY  - CONF
AU  - Kondić, Stefan
AU  - Dobrić, Jelena
AU  - Gluhović, Nina
PY  - 2018
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/1603
AB  - Aluminum alloys, due to its numerous advantages, is widely used in the construction of various types of structures in civil engineering. Design of pedestrian bridge, entirely constructed of extruded elements made of aluminum alloy EN-AW 6082 T6 with cross sections designed to enable the use of innovative joints, is presented in this paper. The design and construction of special bolted joints is presented using the recommendations given in standard for design of aluminum structures CNR-DT 208/2011. Also, calculation of pedestrian bridge vibrations through different design methods is given here. Results of numerical analysis are compared with the recommendations from different currently available standards and literature referring to the comfort criteria of pedestrian bridge vibrations.
PB  - Društvo građevinskih konstruktera Srbije, Beograd
C3  - ASES International congress proceedings / Association of Structural Engineers of Serbia, 15th Congress, September 6-8th, 2018, Zlatibor
T1  - Design of pedestrian bridge according to Eurocode 9
EP  - 495
SP  - 485
UR  - https://hdl.handle.net/21.15107/rcub_grafar_1603
ER  - 
@conference{
author = "Kondić, Stefan and Dobrić, Jelena and Gluhović, Nina",
year = "2018",
abstract = "Aluminum alloys, due to its numerous advantages, is widely used in the construction of various types of structures in civil engineering. Design of pedestrian bridge, entirely constructed of extruded elements made of aluminum alloy EN-AW 6082 T6 with cross sections designed to enable the use of innovative joints, is presented in this paper. The design and construction of special bolted joints is presented using the recommendations given in standard for design of aluminum structures CNR-DT 208/2011. Also, calculation of pedestrian bridge vibrations through different design methods is given here. Results of numerical analysis are compared with the recommendations from different currently available standards and literature referring to the comfort criteria of pedestrian bridge vibrations.",
publisher = "Društvo građevinskih konstruktera Srbije, Beograd",
journal = "ASES International congress proceedings / Association of Structural Engineers of Serbia, 15th Congress, September 6-8th, 2018, Zlatibor",
title = "Design of pedestrian bridge according to Eurocode 9",
pages = "495-485",
url = "https://hdl.handle.net/21.15107/rcub_grafar_1603"
}
Kondić, S., Dobrić, J.,& Gluhović, N.. (2018). Design of pedestrian bridge according to Eurocode 9. in ASES International congress proceedings / Association of Structural Engineers of Serbia, 15th Congress, September 6-8th, 2018, Zlatibor
Društvo građevinskih konstruktera Srbije, Beograd., 485-495.
https://hdl.handle.net/21.15107/rcub_grafar_1603
Kondić S, Dobrić J, Gluhović N. Design of pedestrian bridge according to Eurocode 9. in ASES International congress proceedings / Association of Structural Engineers of Serbia, 15th Congress, September 6-8th, 2018, Zlatibor. 2018;:485-495.
https://hdl.handle.net/21.15107/rcub_grafar_1603 .
Kondić, Stefan, Dobrić, Jelena, Gluhović, Nina, "Design of pedestrian bridge according to Eurocode 9" in ASES International congress proceedings / Association of Structural Engineers of Serbia, 15th Congress, September 6-8th, 2018, Zlatibor (2018):485-495,
https://hdl.handle.net/21.15107/rcub_grafar_1603 .

Poređenje ponašanja tankih cilndričnih ljuski od ugljeničnog čelika i nerđajućeg čelika

Kostadinović Vranešević, Kristina; Gluhović, Nina; Dobrić, Jelena; Spremić, Milan

(Društvo građevinskih konstruktera Srbije, Beograd, 2018)

TY  - CONF
AU  - Kostadinović Vranešević, Kristina
AU  - Gluhović, Nina
AU  - Dobrić, Jelena
AU  - Spremić, Milan
PY  - 2018
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/1595
AB  - Thin-walled cylindrical shells represent one of the most complex constructive elements, considering their behaviour and susceptibility to buckling. In this paper is given a brief theoretical review including the presentation of different currently available design recommendations. Influence of initial imperfections on nonlinear behaviour of cylindrical shells is also presented through numerical analysis. Cylindrical shells with different wall thicknesses and different values of initial imperfections, but constant length and diameter of
shell are analysed. Numerical analysis includes materially and geometrically nonlinear analysis of cylindrical shells, using experimentally obtained stress-strain relation of carbonsteel and
stainless steel. Material nonlinearity and initial geometrical imperfections resulted in significantly lower buckling resistance of cylindrical shells.
PB  - Društvo građevinskih konstruktera Srbije, Beograd
C3  - Zbornik radova sa nacionalnog kongresa DGKS / Društvо građevinskih konstruktera Srbije, 15. kongres, 6-8. septembar 2018, Zlatibor
T1  - Poređenje ponašanja tankih cilndričnih ljuski od ugljeničnog čelika i nerđajućeg čelika
EP  - 528
SP  - 519
UR  - https://hdl.handle.net/21.15107/rcub_grafar_1595
ER  - 
@conference{
author = "Kostadinović Vranešević, Kristina and Gluhović, Nina and Dobrić, Jelena and Spremić, Milan",
year = "2018",
abstract = "Thin-walled cylindrical shells represent one of the most complex constructive elements, considering their behaviour and susceptibility to buckling. In this paper is given a brief theoretical review including the presentation of different currently available design recommendations. Influence of initial imperfections on nonlinear behaviour of cylindrical shells is also presented through numerical analysis. Cylindrical shells with different wall thicknesses and different values of initial imperfections, but constant length and diameter of
shell are analysed. Numerical analysis includes materially and geometrically nonlinear analysis of cylindrical shells, using experimentally obtained stress-strain relation of carbonsteel and
stainless steel. Material nonlinearity and initial geometrical imperfections resulted in significantly lower buckling resistance of cylindrical shells.",
publisher = "Društvo građevinskih konstruktera Srbije, Beograd",
journal = "Zbornik radova sa nacionalnog kongresa DGKS / Društvо građevinskih konstruktera Srbije, 15. kongres, 6-8. septembar 2018, Zlatibor",
title = "Poređenje ponašanja tankih cilndričnih ljuski od ugljeničnog čelika i nerđajućeg čelika",
pages = "528-519",
url = "https://hdl.handle.net/21.15107/rcub_grafar_1595"
}
Kostadinović Vranešević, K., Gluhović, N., Dobrić, J.,& Spremić, M.. (2018). Poređenje ponašanja tankih cilndričnih ljuski od ugljeničnog čelika i nerđajućeg čelika. in Zbornik radova sa nacionalnog kongresa DGKS / Društvо građevinskih konstruktera Srbije, 15. kongres, 6-8. septembar 2018, Zlatibor
Društvo građevinskih konstruktera Srbije, Beograd., 519-528.
https://hdl.handle.net/21.15107/rcub_grafar_1595
Kostadinović Vranešević K, Gluhović N, Dobrić J, Spremić M. Poređenje ponašanja tankih cilndričnih ljuski od ugljeničnog čelika i nerđajućeg čelika. in Zbornik radova sa nacionalnog kongresa DGKS / Društvо građevinskih konstruktera Srbije, 15. kongres, 6-8. septembar 2018, Zlatibor. 2018;:519-528.
https://hdl.handle.net/21.15107/rcub_grafar_1595 .
Kostadinović Vranešević, Kristina, Gluhović, Nina, Dobrić, Jelena, Spremić, Milan, "Poređenje ponašanja tankih cilndričnih ljuski od ugljeničnog čelika i nerđajućeg čelika" in Zbornik radova sa nacionalnog kongresa DGKS / Društvо građevinskih konstruktera Srbije, 15. kongres, 6-8. septembar 2018, Zlatibor (2018):519-528,
https://hdl.handle.net/21.15107/rcub_grafar_1595 .

Resistance and serviceability analysis of steel footbridge structure according to Eurocode

Kruškonja, Jagoda; Dobrić, Jelena; Gluhović, Nina

(Društvo građevinskih konstruktera Srbije, Beograd, 2018)

TY  - CONF
AU  - Kruškonja, Jagoda
AU  - Dobrić, Jelena
AU  - Gluhović, Nina
PY  - 2018
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/1624
AB  - This paper briefly presents resistance and serviceability analysis of steel footbridge structure. The main structural system consists of cold-formed members, which were designed according to EN 1993-1-3. Analysis of vibration of the footbridge structure was performed, including comparative study from the aspect of different criteria regarding the comfort according to Eurocode and SETRA/AFGC recommendations. Additionally, the paper compares behavior of steel footbridge with static and structural equivalent footbridge whose base material is aluminum alloy.
PB  - Društvo građevinskih konstruktera Srbije, Beograd
C3  - ASES International congress proceedings / Association of Structural Engineers of Serbia, 15th Congress, September 6-8th, 2018, Zlatibor
T1  - Resistance and serviceability analysis of steel footbridge structure according to Eurocode
EP  - 515
SP  - 506
UR  - https://hdl.handle.net/21.15107/rcub_grafar_1624
ER  - 
@conference{
author = "Kruškonja, Jagoda and Dobrić, Jelena and Gluhović, Nina",
year = "2018",
abstract = "This paper briefly presents resistance and serviceability analysis of steel footbridge structure. The main structural system consists of cold-formed members, which were designed according to EN 1993-1-3. Analysis of vibration of the footbridge structure was performed, including comparative study from the aspect of different criteria regarding the comfort according to Eurocode and SETRA/AFGC recommendations. Additionally, the paper compares behavior of steel footbridge with static and structural equivalent footbridge whose base material is aluminum alloy.",
publisher = "Društvo građevinskih konstruktera Srbije, Beograd",
journal = "ASES International congress proceedings / Association of Structural Engineers of Serbia, 15th Congress, September 6-8th, 2018, Zlatibor",
title = "Resistance and serviceability analysis of steel footbridge structure according to Eurocode",
pages = "515-506",
url = "https://hdl.handle.net/21.15107/rcub_grafar_1624"
}
Kruškonja, J., Dobrić, J.,& Gluhović, N.. (2018). Resistance and serviceability analysis of steel footbridge structure according to Eurocode. in ASES International congress proceedings / Association of Structural Engineers of Serbia, 15th Congress, September 6-8th, 2018, Zlatibor
Društvo građevinskih konstruktera Srbije, Beograd., 506-515.
https://hdl.handle.net/21.15107/rcub_grafar_1624
Kruškonja J, Dobrić J, Gluhović N. Resistance and serviceability analysis of steel footbridge structure according to Eurocode. in ASES International congress proceedings / Association of Structural Engineers of Serbia, 15th Congress, September 6-8th, 2018, Zlatibor. 2018;:506-515.
https://hdl.handle.net/21.15107/rcub_grafar_1624 .
Kruškonja, Jagoda, Dobrić, Jelena, Gluhović, Nina, "Resistance and serviceability analysis of steel footbridge structure according to Eurocode" in ASES International congress proceedings / Association of Structural Engineers of Serbia, 15th Congress, September 6-8th, 2018, Zlatibor (2018):506-515,
https://hdl.handle.net/21.15107/rcub_grafar_1624 .

Recent research on ductility of perforated shear connectors

Gluhović, Nina; Spremić, Milan; Marković, Zlatko

(Društvo građevinskih konstruktera Srbije, Beograd, 2018)

TY  - CONF
AU  - Gluhović, Nina
AU  - Spremić, Milan
AU  - Marković, Zlatko
PY  - 2018
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/1652
AB  - Significant implementation of Perfobond shear connectors in construction of composite steel-concrete structures resluted in development of entirely new type of shear connectors, denoted as perforated shear connectors. Except the shear resistance of this type of shear connector, the overall behaviour of shear connection is strongly influenced by shear connector geometry. Ductility of shear connector, which is strongly influenced by connectors geometry, defines the behaviour of shear connection. The results of resent research on ductility of perforated shear connectors are obtained from numerical models which are calibrated with results of experimental investigation of this type of shear connector. The results of extensive numerical analysis were used for definition of direct relation between connectors ductility and geometry and presented in this paper.
PB  - Društvo građevinskih konstruktera Srbije, Beograd
C3  - ASES International congress proceedings / Association of Structural Engineers of Serbia, 15th Congress, September 6-8th, 2018, Zlatibor
T1  - Recent research on ductility of perforated shear connectors
EP  - 634
SP  - 627
UR  - https://hdl.handle.net/21.15107/rcub_grafar_1652
ER  - 
@conference{
author = "Gluhović, Nina and Spremić, Milan and Marković, Zlatko",
year = "2018",
abstract = "Significant implementation of Perfobond shear connectors in construction of composite steel-concrete structures resluted in development of entirely new type of shear connectors, denoted as perforated shear connectors. Except the shear resistance of this type of shear connector, the overall behaviour of shear connection is strongly influenced by shear connector geometry. Ductility of shear connector, which is strongly influenced by connectors geometry, defines the behaviour of shear connection. The results of resent research on ductility of perforated shear connectors are obtained from numerical models which are calibrated with results of experimental investigation of this type of shear connector. The results of extensive numerical analysis were used for definition of direct relation between connectors ductility and geometry and presented in this paper.",
publisher = "Društvo građevinskih konstruktera Srbije, Beograd",
journal = "ASES International congress proceedings / Association of Structural Engineers of Serbia, 15th Congress, September 6-8th, 2018, Zlatibor",
title = "Recent research on ductility of perforated shear connectors",
pages = "634-627",
url = "https://hdl.handle.net/21.15107/rcub_grafar_1652"
}
Gluhović, N., Spremić, M.,& Marković, Z.. (2018). Recent research on ductility of perforated shear connectors. in ASES International congress proceedings / Association of Structural Engineers of Serbia, 15th Congress, September 6-8th, 2018, Zlatibor
Društvo građevinskih konstruktera Srbije, Beograd., 627-634.
https://hdl.handle.net/21.15107/rcub_grafar_1652
Gluhović N, Spremić M, Marković Z. Recent research on ductility of perforated shear connectors. in ASES International congress proceedings / Association of Structural Engineers of Serbia, 15th Congress, September 6-8th, 2018, Zlatibor. 2018;:627-634.
https://hdl.handle.net/21.15107/rcub_grafar_1652 .
Gluhović, Nina, Spremić, Milan, Marković, Zlatko, "Recent research on ductility of perforated shear connectors" in ASES International congress proceedings / Association of Structural Engineers of Serbia, 15th Congress, September 6-8th, 2018, Zlatibor (2018):627-634,
https://hdl.handle.net/21.15107/rcub_grafar_1652 .

The influence of a roof mounted small-scale HAWT on headed studs fatigue resistance

Jakovljević, Isidora; Gluhović, Nina; Spremić, Milan; Marković, Zlatko

(TU1304 COST Action, 2018)

TY  - CONF
AU  - Jakovljević, Isidora
AU  - Gluhović, Nina
AU  - Spremić, Milan
AU  - Marković, Zlatko
PY  - 2018
UR  - http://www.winercost.com/cost_files/WINERCOST18_Proceedings.pdf
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/1863
AB  - Installation of small-scale wind turbines in urban regions can gain higher energy efficiency, considering that energy production takes place at the place of its consumption. The aim of this work is to investigate effects of installation of a small-scale horizontal axis wind turbine (HAWT) on a roof structure of an existing building. This paper is focused on fatigue resistance of headed studs that are preinstalled in the building roof composite steel-concrete deck to ensure shear connection and that are indirectly dynamically loaded during wind turbine operation. Turbulent wind profiles with mean wind speeds from 3 m/s up to 15 m/s are generated and applied on the model of HAWT with 5 m rotor diameter using Ashes software package. Time-dependent forces and bending moments induced by wind turbine operation are applied on the composite roof deck model. Based on the time-history of transverse force in the composite steel-concrete beam and wind speed records during a year, fatigue cumulative damage of headed studs is calculated according to Eurocode. It is obtained that installation of HAWT do not significantly affect residual life of headed studs with reference to fatigue.
PB  - TU1304 COST Action
C3  - The International Conference on Wind Energy Harvesting, 21-23 March 2018, Catanzaro, Italy
T1  - The influence of a roof mounted small-scale HAWT on headed studs fatigue resistance
EP  - 139
SP  - 133
UR  - https://hdl.handle.net/21.15107/rcub_grafar_1863
ER  - 
@conference{
author = "Jakovljević, Isidora and Gluhović, Nina and Spremić, Milan and Marković, Zlatko",
year = "2018",
abstract = "Installation of small-scale wind turbines in urban regions can gain higher energy efficiency, considering that energy production takes place at the place of its consumption. The aim of this work is to investigate effects of installation of a small-scale horizontal axis wind turbine (HAWT) on a roof structure of an existing building. This paper is focused on fatigue resistance of headed studs that are preinstalled in the building roof composite steel-concrete deck to ensure shear connection and that are indirectly dynamically loaded during wind turbine operation. Turbulent wind profiles with mean wind speeds from 3 m/s up to 15 m/s are generated and applied on the model of HAWT with 5 m rotor diameter using Ashes software package. Time-dependent forces and bending moments induced by wind turbine operation are applied on the composite roof deck model. Based on the time-history of transverse force in the composite steel-concrete beam and wind speed records during a year, fatigue cumulative damage of headed studs is calculated according to Eurocode. It is obtained that installation of HAWT do not significantly affect residual life of headed studs with reference to fatigue.",
publisher = "TU1304 COST Action",
journal = "The International Conference on Wind Energy Harvesting, 21-23 March 2018, Catanzaro, Italy",
title = "The influence of a roof mounted small-scale HAWT on headed studs fatigue resistance",
pages = "139-133",
url = "https://hdl.handle.net/21.15107/rcub_grafar_1863"
}
Jakovljević, I., Gluhović, N., Spremić, M.,& Marković, Z.. (2018). The influence of a roof mounted small-scale HAWT on headed studs fatigue resistance. in The International Conference on Wind Energy Harvesting, 21-23 March 2018, Catanzaro, Italy
TU1304 COST Action., 133-139.
https://hdl.handle.net/21.15107/rcub_grafar_1863
Jakovljević I, Gluhović N, Spremić M, Marković Z. The influence of a roof mounted small-scale HAWT on headed studs fatigue resistance. in The International Conference on Wind Energy Harvesting, 21-23 March 2018, Catanzaro, Italy. 2018;:133-139.
https://hdl.handle.net/21.15107/rcub_grafar_1863 .
Jakovljević, Isidora, Gluhović, Nina, Spremić, Milan, Marković, Zlatko, "The influence of a roof mounted small-scale HAWT on headed studs fatigue resistance" in The International Conference on Wind Energy Harvesting, 21-23 March 2018, Catanzaro, Italy (2018):133-139,
https://hdl.handle.net/21.15107/rcub_grafar_1863 .