Cvitkovac, Mile

Link to this page

Authority KeyName Variants
7078de39-a992-4496-92b1-bfed8bc5fe29
  • Cvitkovac, Mile (7)
Projects

Author's Bibliography

Sistem za merenje protoka na ulazima u cevne turbine na bazi elektromagnetnih senzora brzine

Prodanović, Dušan; Ivetić, Damjan; Milivojević, Nikola; Vojt, Predrag; Cvitkovac, Mile

(2021)


                                            

                                            
Prodanović, D., Ivetić, D., Milivojević, N., Vojt, P.,& Cvitkovac, M.. (2021). Sistem za merenje protoka na ulazima u cevne turbine na bazi elektromagnetnih senzora brzine. in Investitor: Elektroprivreda Srbije.
https://hdl.handle.net/21.15107/rcub_grafar_3319
Prodanović D, Ivetić D, Milivojević N, Vojt P, Cvitkovac M. Sistem za merenje protoka na ulazima u cevne turbine na bazi elektromagnetnih senzora brzine. in Investitor: Elektroprivreda Srbije. 2021;.
https://hdl.handle.net/21.15107/rcub_grafar_3319 .
Prodanović, Dušan, Ivetić, Damjan, Milivojević, Nikola, Vojt, Predrag, Cvitkovac, Mile, "Sistem za merenje protoka na ulazima u cevne turbine na bazi elektromagnetnih senzora brzine" in Investitor: Elektroprivreda Srbije (2021),
https://hdl.handle.net/21.15107/rcub_grafar_3319 .

Merenje protoka vode u tunelima pri kombinovanim uslovima tečenja: primer tunela Dabarsko Polje - Fatničko polje

Ivetić, Damjan; Prodanović, Dušan; Cvitkovac, Mile

(Srpsko društvo za hidraulička istraživanja i Srpsko društvo za hidrologiju, 2018)

TY  - CONF
AU  - Ivetić, Damjan
AU  - Prodanović, Dušan
AU  - Cvitkovac, Mile
PY  - 2018
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/3203
AB  - U opštem slučaju, metode za merenje protoka vode se mogu klasifikovati prema uslovima tečenja na mernom mestu, pa se tako određene metode koriste u sistemima pod pritiskom dok nešto drugačije u sistemima gde se javlja tečenje sa slobodnom površinom. U određenim slučajevima, na mernom mestu se može javiti i tečenje pod pritiskom i sa slobodnom površinom, odnosno tzv. kombinovani uslovi tečenja. U ovom radu analiziran je jedan upravo takav slučaj, derivacioni tunel između Dabarskog i Fatničkog Polja u okviru sistema Hidroelektrane na Trebišnjici (HET). Glavne karakteristike ovog tunela, pored kombinovanih uslova tečenja, su i impozantne dimenzije, gde prečnik varira od 5,0 m do oko 5,6 m, kao i bidirekcioni raspon protoka od -40 do ~55 m3/s. Za 
potrebe merenja protoka projektovano je i izvedeno jedno merno mesto unutar tunela, neposredno uz izlazno/ulaznu građevinu u Fatničkom polju, opremljeno sa četiri ravne EM sonde, dva logera pritiska i dve kontrolne EM sonde tipa „Ajkulino krilo“. Imajući u vidu karakteristike tunela kao i merne metode, neophodno je pažljivo uspostaviti korelaciju između izmerene brzine i srednje profilske, odnosno lokalno kalibrisati ravne EM senzore brzine. U radu je analizirana mogućnost lokalne kalibracije ravnih EM senzora brzine pomoću kontrolnih EM sondi „Ajkulino krilo“. Dobijeni rezultati su upoređeni sa rezultatima „suve kalibracije“ sprovedene korišćenjem teorijskog rasporeda brzine i jednodimenzionalne težinske funkcije.
PB  - Srpsko društvo za hidraulička istraživanja i Srpsko društvo za hidrologiju
C3  - 18. Savetovanje SDHI i SDH, Niš, Srbija
T1  - Merenje protoka vode u tunelima pri kombinovanim uslovima  tečenja: primer tunela Dabarsko Polje - Fatničko polje
UR  - https://hdl.handle.net/21.15107/rcub_grafar_3203
ER  - 
@conference{
author = "Ivetić, Damjan and Prodanović, Dušan and Cvitkovac, Mile",
year = "2018",
abstract = "U opštem slučaju, metode za merenje protoka vode se mogu klasifikovati prema uslovima tečenja na mernom mestu, pa se tako određene metode koriste u sistemima pod pritiskom dok nešto drugačije u sistemima gde se javlja tečenje sa slobodnom površinom. U određenim slučajevima, na mernom mestu se može javiti i tečenje pod pritiskom i sa slobodnom površinom, odnosno tzv. kombinovani uslovi tečenja. U ovom radu analiziran je jedan upravo takav slučaj, derivacioni tunel između Dabarskog i Fatničkog Polja u okviru sistema Hidroelektrane na Trebišnjici (HET). Glavne karakteristike ovog tunela, pored kombinovanih uslova tečenja, su i impozantne dimenzije, gde prečnik varira od 5,0 m do oko 5,6 m, kao i bidirekcioni raspon protoka od -40 do ~55 m3/s. Za 
potrebe merenja protoka projektovano je i izvedeno jedno merno mesto unutar tunela, neposredno uz izlazno/ulaznu građevinu u Fatničkom polju, opremljeno sa četiri ravne EM sonde, dva logera pritiska i dve kontrolne EM sonde tipa „Ajkulino krilo“. Imajući u vidu karakteristike tunela kao i merne metode, neophodno je pažljivo uspostaviti korelaciju između izmerene brzine i srednje profilske, odnosno lokalno kalibrisati ravne EM senzore brzine. U radu je analizirana mogućnost lokalne kalibracije ravnih EM senzora brzine pomoću kontrolnih EM sondi „Ajkulino krilo“. Dobijeni rezultati su upoređeni sa rezultatima „suve kalibracije“ sprovedene korišćenjem teorijskog rasporeda brzine i jednodimenzionalne težinske funkcije.",
publisher = "Srpsko društvo za hidraulička istraživanja i Srpsko društvo za hidrologiju",
journal = "18. Savetovanje SDHI i SDH, Niš, Srbija",
title = "Merenje protoka vode u tunelima pri kombinovanim uslovima  tečenja: primer tunela Dabarsko Polje - Fatničko polje",
url = "https://hdl.handle.net/21.15107/rcub_grafar_3203"
}
Ivetić, D., Prodanović, D.,& Cvitkovac, M.. (2018). Merenje protoka vode u tunelima pri kombinovanim uslovima  tečenja: primer tunela Dabarsko Polje - Fatničko polje. in 18. Savetovanje SDHI i SDH, Niš, Srbija
Srpsko društvo za hidraulička istraživanja i Srpsko društvo za hidrologiju..
https://hdl.handle.net/21.15107/rcub_grafar_3203
Ivetić D, Prodanović D, Cvitkovac M. Merenje protoka vode u tunelima pri kombinovanim uslovima  tečenja: primer tunela Dabarsko Polje - Fatničko polje. in 18. Savetovanje SDHI i SDH, Niš, Srbija. 2018;.
https://hdl.handle.net/21.15107/rcub_grafar_3203 .
Ivetić, Damjan, Prodanović, Dušan, Cvitkovac, Mile, "Merenje protoka vode u tunelima pri kombinovanim uslovima  tečenja: primer tunela Dabarsko Polje - Fatničko polje" in 18. Savetovanje SDHI i SDH, Niš, Srbija (2018),
https://hdl.handle.net/21.15107/rcub_grafar_3203 .

Merenje protoka vode u tunelima pri kombinovanim uslovima tečenja: primer tunela Dabarsko polje - Fatničko polje

Ivetić, Damjan; Prodanović, Dušan; Cvitkovac, Mile

(2018)

TY  - JOUR
AU  - Ivetić, Damjan
AU  - Prodanović, Dušan
AU  - Cvitkovac, Mile
PY  - 2018
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/1113
T2  - Vodoprivreda
T1  - Merenje protoka vode u tunelima pri kombinovanim uslovima tečenja: primer tunela Dabarsko polje - Fatničko polje
EP  - 244
IS  - 4-6
SP  - 229
VL  - 50
UR  - https://hdl.handle.net/21.15107/rcub_grafar_1113
ER  - 
@article{
author = "Ivetić, Damjan and Prodanović, Dušan and Cvitkovac, Mile",
year = "2018",
journal = "Vodoprivreda",
title = "Merenje protoka vode u tunelima pri kombinovanim uslovima tečenja: primer tunela Dabarsko polje - Fatničko polje",
pages = "244-229",
number = "4-6",
volume = "50",
url = "https://hdl.handle.net/21.15107/rcub_grafar_1113"
}
Ivetić, D., Prodanović, D.,& Cvitkovac, M.. (2018). Merenje protoka vode u tunelima pri kombinovanim uslovima tečenja: primer tunela Dabarsko polje - Fatničko polje. in Vodoprivreda, 50(4-6), 229-244.
https://hdl.handle.net/21.15107/rcub_grafar_1113
Ivetić D, Prodanović D, Cvitkovac M. Merenje protoka vode u tunelima pri kombinovanim uslovima tečenja: primer tunela Dabarsko polje - Fatničko polje. in Vodoprivreda. 2018;50(4-6):229-244.
https://hdl.handle.net/21.15107/rcub_grafar_1113 .
Ivetić, Damjan, Prodanović, Dušan, Cvitkovac, Mile, "Merenje protoka vode u tunelima pri kombinovanim uslovima tečenja: primer tunela Dabarsko polje - Fatničko polje" in Vodoprivreda, 50, no. 4-6 (2018):229-244,
https://hdl.handle.net/21.15107/rcub_grafar_1113 .

Using CFD and real-magnetic field of EM probes to improve the accuracy of flow measurements in mixed flow conditions

Ivetić, Damjan; Prodanović, Dušan; Cvitkovac, Mile

(IAHR Joint Committee on Urban Drainage, 2017)

TY  - CONF
AU  - Ivetić, Damjan
AU  - Prodanović, Dušan
AU  - Cvitkovac, Mile
PY  - 2017
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/3202
AB  - Flow measurement in mixed flow conditions is a challenging task, which can be performed only by few techniques like ultrasonic and electromagnetic. Usually despite the flowmeter’s special design, the systematic uncertainty of flow rate remains high. In order to overcome this issue, additional site-specific calibration procedure for flat EM sensors is presented in this paper. Procedure includes both a hydraulic and magnetic field analysis. Concept of its application in the engineering practice example are presented.
PB  - IAHR Joint Committee on Urban Drainage
C3  - 23rd European Junior Scientists Workshop on Monitoring Urban Drainage Systems, Chichilianne, France, 15-20 May 2017.
T1  - Using CFD and real-magnetic field of EM probes to improve the accuracy of  flow measurements in mixed flow conditions
UR  - https://hdl.handle.net/21.15107/rcub_grafar_3202
ER  - 
@conference{
author = "Ivetić, Damjan and Prodanović, Dušan and Cvitkovac, Mile",
year = "2017",
abstract = "Flow measurement in mixed flow conditions is a challenging task, which can be performed only by few techniques like ultrasonic and electromagnetic. Usually despite the flowmeter’s special design, the systematic uncertainty of flow rate remains high. In order to overcome this issue, additional site-specific calibration procedure for flat EM sensors is presented in this paper. Procedure includes both a hydraulic and magnetic field analysis. Concept of its application in the engineering practice example are presented.",
publisher = "IAHR Joint Committee on Urban Drainage",
journal = "23rd European Junior Scientists Workshop on Monitoring Urban Drainage Systems, Chichilianne, France, 15-20 May 2017.",
title = "Using CFD and real-magnetic field of EM probes to improve the accuracy of  flow measurements in mixed flow conditions",
url = "https://hdl.handle.net/21.15107/rcub_grafar_3202"
}
Ivetić, D., Prodanović, D.,& Cvitkovac, M.. (2017). Using CFD and real-magnetic field of EM probes to improve the accuracy of  flow measurements in mixed flow conditions. in 23rd European Junior Scientists Workshop on Monitoring Urban Drainage Systems, Chichilianne, France, 15-20 May 2017.
IAHR Joint Committee on Urban Drainage..
https://hdl.handle.net/21.15107/rcub_grafar_3202
Ivetić D, Prodanović D, Cvitkovac M. Using CFD and real-magnetic field of EM probes to improve the accuracy of  flow measurements in mixed flow conditions. in 23rd European Junior Scientists Workshop on Monitoring Urban Drainage Systems, Chichilianne, France, 15-20 May 2017.. 2017;.
https://hdl.handle.net/21.15107/rcub_grafar_3202 .
Ivetić, Damjan, Prodanović, Dušan, Cvitkovac, Mile, "Using CFD and real-magnetic field of EM probes to improve the accuracy of  flow measurements in mixed flow conditions" in 23rd European Junior Scientists Workshop on Monitoring Urban Drainage Systems, Chichilianne, France, 15-20 May 2017. (2017),
https://hdl.handle.net/21.15107/rcub_grafar_3202 .

Improvement of EM flow meters accuracy through site-specific CFD calibration case study HPS Trebinje

Ivetić, Damjan; Prodanović, Dušan; Cvitkovac, Mile

(Budapest University of Technology and Economics, Department of Applied Biotechnology and Food Science, Budapest, 2017)

TY  - CONF
AU  - Ivetić, Damjan
AU  - Prodanović, Dušan
AU  - Cvitkovac, Mile
PY  - 2017
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/1536
PB  - Budapest University of Technology and Economics, Department of Applied Biotechnology and Food Science, Budapest
C3  - IWA 9th Eastern European Young Water Professionals Conference
T1  - Improvement of EM flow meters accuracy through site-specific CFD calibration case study HPS Trebinje
UR  - https://hdl.handle.net/21.15107/rcub_grafar_1536
ER  - 
@conference{
author = "Ivetić, Damjan and Prodanović, Dušan and Cvitkovac, Mile",
year = "2017",
publisher = "Budapest University of Technology and Economics, Department of Applied Biotechnology and Food Science, Budapest",
journal = "IWA 9th Eastern European Young Water Professionals Conference",
title = "Improvement of EM flow meters accuracy through site-specific CFD calibration case study HPS Trebinje",
url = "https://hdl.handle.net/21.15107/rcub_grafar_1536"
}
Ivetić, D., Prodanović, D.,& Cvitkovac, M.. (2017). Improvement of EM flow meters accuracy through site-specific CFD calibration case study HPS Trebinje. in IWA 9th Eastern European Young Water Professionals Conference
Budapest University of Technology and Economics, Department of Applied Biotechnology and Food Science, Budapest..
https://hdl.handle.net/21.15107/rcub_grafar_1536
Ivetić D, Prodanović D, Cvitkovac M. Improvement of EM flow meters accuracy through site-specific CFD calibration case study HPS Trebinje. in IWA 9th Eastern European Young Water Professionals Conference. 2017;.
https://hdl.handle.net/21.15107/rcub_grafar_1536 .
Ivetić, Damjan, Prodanović, Dušan, Cvitkovac, Mile, "Improvement of EM flow meters accuracy through site-specific CFD calibration case study HPS Trebinje" in IWA 9th Eastern European Young Water Professionals Conference (2017),
https://hdl.handle.net/21.15107/rcub_grafar_1536 .

Improved flow measurement using EM flat probes in mixed flow conditions

Ivetić, Damjan; Prodanović, Dušan; Cvitkovac, Mile

(ICUD 2017, 2017)

TY  - CONF
AU  - Ivetić, Damjan
AU  - Prodanović, Dušan
AU  - Cvitkovac, Mile
PY  - 2017
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/1735
AB  - One of the commonly used approaches, for the flow measurements in sewer systems, are velocity-area methods. Although, it is reported that the velocity sensors operate with high uncertainty, the popularity of these methods stem from the fact that they can be applied in wide range of hydraulic conditions including the mixed flow conditions. Uncertainties are related both to the applied instruments and properties of the measurement site.  In order to overcome this issue, additional site-specific calibration procedure for flat EM sensors is presented in this paper. Concept of its application in the engineering practice example are presented.
PB  - ICUD 2017
C3  - Proceeding of 14th IWA / IAHR International Conference on Urban Drainage (ICUD2017)
T1  - Improved flow measurement using EM flat probes in mixed flow conditions
UR  - https://hdl.handle.net/21.15107/rcub_grafar_1735
ER  - 
@conference{
author = "Ivetić, Damjan and Prodanović, Dušan and Cvitkovac, Mile",
year = "2017",
abstract = "One of the commonly used approaches, for the flow measurements in sewer systems, are velocity-area methods. Although, it is reported that the velocity sensors operate with high uncertainty, the popularity of these methods stem from the fact that they can be applied in wide range of hydraulic conditions including the mixed flow conditions. Uncertainties are related both to the applied instruments and properties of the measurement site.  In order to overcome this issue, additional site-specific calibration procedure for flat EM sensors is presented in this paper. Concept of its application in the engineering practice example are presented.",
publisher = "ICUD 2017",
journal = "Proceeding of 14th IWA / IAHR International Conference on Urban Drainage (ICUD2017)",
title = "Improved flow measurement using EM flat probes in mixed flow conditions",
url = "https://hdl.handle.net/21.15107/rcub_grafar_1735"
}
Ivetić, D., Prodanović, D.,& Cvitkovac, M.. (2017). Improved flow measurement using EM flat probes in mixed flow conditions. in Proceeding of 14th IWA / IAHR International Conference on Urban Drainage (ICUD2017)
ICUD 2017..
https://hdl.handle.net/21.15107/rcub_grafar_1735
Ivetić D, Prodanović D, Cvitkovac M. Improved flow measurement using EM flat probes in mixed flow conditions. in Proceeding of 14th IWA / IAHR International Conference on Urban Drainage (ICUD2017). 2017;.
https://hdl.handle.net/21.15107/rcub_grafar_1735 .
Ivetić, Damjan, Prodanović, Dušan, Cvitkovac, Mile, "Improved flow measurement using EM flat probes in mixed flow conditions" in Proceeding of 14th IWA / IAHR International Conference on Urban Drainage (ICUD2017) (2017),
https://hdl.handle.net/21.15107/rcub_grafar_1735 .

Improvement of the flow measuring methodology with the flat electromagnetic velocity probes

Ivetić, Damjan; Prodanović, Dušan; Stojadinović, Luka; Cvitkovac, Mile

(Jugoslovensko društvo za odvodnjavanje i navodnjavanje, Beograd, 2017)

TY  - JOUR
AU  - Ivetić, Damjan
AU  - Prodanović, Dušan
AU  - Stojadinović, Luka
AU  - Cvitkovac, Mile
PY  - 2017
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/856
AB  - One of the commonly used approaches, for the flow measurements in open chanel hydraulic systems, is to measure one depth and use the stable Q-H relationship to compute the flow rate. If this method is inappropriate, the velocity-area method has to be used: both area (depth) and mean velocity are measured in order to compute the flow rate. Although, it is reported that the velocity sensors operate with high uncertainty, the popularity of these methods stem from the fact that they can be applied in wide range of hydraulic conditions including the mixed flow conditions. Uncertainties are related both to the applied instruments and properties of the measurement site. While Doppler probes are preffered nowadays in the hydraulic systems, electromagnetic probes have certain adventages which are found to be useful in the methodology presented in this paper. Here, so called flat EM velocity probes are analyzed, which can be used instead of Doppler probes for the flow measurements. Due to the more rigourous operating principle, particular weighting functions can be derived in order to define contributions from different parts of the flow to the measured signal. Reduction of the uncertainty can be obtained through combination of the weighting functions with site-specific velocity fields computed with CFD simulations, In order to overcome the high uncertainty issue, additional site-specific calibration procedure for flat EM sensors is presented in this paper. Concept of its application in the engineering practice example are presented.
AB  - Najčešće korišćen način merenja protoka u hidrotehničkim sistemima sa otvorenim tokom je preko merenja jedne dubine i preračunavanjem u protok korišćenjem Q-H krive. U uslovima kada nije moguće jednoznačno uspostaviti Q-H vezu, neophodno je koristiti metodu Brzina-Proticajni presek, gde se odvojeno mere (srednja) proticajna brzina i dubina. Iako su dosadašnja istraživanja pokazala da senzori brzine često rade sa visokom mernom neodređenošću, ovaj pristup je popularan zbog mogućnosti primene u širokom spektru hidrauličkih problema. Merna neodređenost u obračunatom protoku ima dvojaki karakter i rezultat je neodređenosti samog merenja brzine i dubine, kao i doprinosa usled nestandardnih uslova na mernom mestu. Iako se u hidrauličkim sistemima u poslednje vreme preferiraju ultrazvučne Dopler sonde, elekromagnetne (EM) sonde poseduju prednosti u realnim uslovima rada posebno u sistemima sa otpadnim vodama. U ovom radu, analizirane su ravne EM sonde za brzinu, koje se mogu koristiti umesto Dopler sondi za merenje protoka. Zbog jasnijeg principa rada EM sondi, moguće je definisati posebne težinske funkcije kojima se opisuje koliko koji deo polja brzina utiče na izlazni signal uređaja. Koristeći težinske funkcije u kombinaciji sa modeliranim realnim strujnim poljem, dobijenim pomoću prostornih numeričkih simulacija turbulentnog toka, moguće je smanjiti mernu neodređenost uređaja. Predložena metodologija je klasifikovana kao naknadna kalibracija EM uređaja prema uslovima na mernom mestu. Koncept njene primene je prikazan kroz praktičan primer.
PB  - Jugoslovensko društvo za odvodnjavanje i navodnjavanje, Beograd
T2  - Vodoprivreda
T1  - Improvement of the flow measuring methodology with the flat electromagnetic velocity probes
T1  - Unapređenje metodologije merenja protoka pomoću ravnih elektromagnetnih senzora brzine
EP  - 102
IS  - 1-3
SP  - 93
VL  - 49
UR  - https://hdl.handle.net/21.15107/rcub_grafar_856
ER  - 
@article{
author = "Ivetić, Damjan and Prodanović, Dušan and Stojadinović, Luka and Cvitkovac, Mile",
year = "2017",
abstract = "One of the commonly used approaches, for the flow measurements in open chanel hydraulic systems, is to measure one depth and use the stable Q-H relationship to compute the flow rate. If this method is inappropriate, the velocity-area method has to be used: both area (depth) and mean velocity are measured in order to compute the flow rate. Although, it is reported that the velocity sensors operate with high uncertainty, the popularity of these methods stem from the fact that they can be applied in wide range of hydraulic conditions including the mixed flow conditions. Uncertainties are related both to the applied instruments and properties of the measurement site. While Doppler probes are preffered nowadays in the hydraulic systems, electromagnetic probes have certain adventages which are found to be useful in the methodology presented in this paper. Here, so called flat EM velocity probes are analyzed, which can be used instead of Doppler probes for the flow measurements. Due to the more rigourous operating principle, particular weighting functions can be derived in order to define contributions from different parts of the flow to the measured signal. Reduction of the uncertainty can be obtained through combination of the weighting functions with site-specific velocity fields computed with CFD simulations, In order to overcome the high uncertainty issue, additional site-specific calibration procedure for flat EM sensors is presented in this paper. Concept of its application in the engineering practice example are presented., Najčešće korišćen način merenja protoka u hidrotehničkim sistemima sa otvorenim tokom je preko merenja jedne dubine i preračunavanjem u protok korišćenjem Q-H krive. U uslovima kada nije moguće jednoznačno uspostaviti Q-H vezu, neophodno je koristiti metodu Brzina-Proticajni presek, gde se odvojeno mere (srednja) proticajna brzina i dubina. Iako su dosadašnja istraživanja pokazala da senzori brzine često rade sa visokom mernom neodređenošću, ovaj pristup je popularan zbog mogućnosti primene u širokom spektru hidrauličkih problema. Merna neodređenost u obračunatom protoku ima dvojaki karakter i rezultat je neodređenosti samog merenja brzine i dubine, kao i doprinosa usled nestandardnih uslova na mernom mestu. Iako se u hidrauličkim sistemima u poslednje vreme preferiraju ultrazvučne Dopler sonde, elekromagnetne (EM) sonde poseduju prednosti u realnim uslovima rada posebno u sistemima sa otpadnim vodama. U ovom radu, analizirane su ravne EM sonde za brzinu, koje se mogu koristiti umesto Dopler sondi za merenje protoka. Zbog jasnijeg principa rada EM sondi, moguće je definisati posebne težinske funkcije kojima se opisuje koliko koji deo polja brzina utiče na izlazni signal uređaja. Koristeći težinske funkcije u kombinaciji sa modeliranim realnim strujnim poljem, dobijenim pomoću prostornih numeričkih simulacija turbulentnog toka, moguće je smanjiti mernu neodređenost uređaja. Predložena metodologija je klasifikovana kao naknadna kalibracija EM uređaja prema uslovima na mernom mestu. Koncept njene primene je prikazan kroz praktičan primer.",
publisher = "Jugoslovensko društvo za odvodnjavanje i navodnjavanje, Beograd",
journal = "Vodoprivreda",
title = "Improvement of the flow measuring methodology with the flat electromagnetic velocity probes, Unapređenje metodologije merenja protoka pomoću ravnih elektromagnetnih senzora brzine",
pages = "102-93",
number = "1-3",
volume = "49",
url = "https://hdl.handle.net/21.15107/rcub_grafar_856"
}
Ivetić, D., Prodanović, D., Stojadinović, L.,& Cvitkovac, M.. (2017). Improvement of the flow measuring methodology with the flat electromagnetic velocity probes. in Vodoprivreda
Jugoslovensko društvo za odvodnjavanje i navodnjavanje, Beograd., 49(1-3), 93-102.
https://hdl.handle.net/21.15107/rcub_grafar_856
Ivetić D, Prodanović D, Stojadinović L, Cvitkovac M. Improvement of the flow measuring methodology with the flat electromagnetic velocity probes. in Vodoprivreda. 2017;49(1-3):93-102.
https://hdl.handle.net/21.15107/rcub_grafar_856 .
Ivetić, Damjan, Prodanović, Dušan, Stojadinović, Luka, Cvitkovac, Mile, "Improvement of the flow measuring methodology with the flat electromagnetic velocity probes" in Vodoprivreda, 49, no. 1-3 (2017):93-102,
https://hdl.handle.net/21.15107/rcub_grafar_856 .