Ivanović, Jovana

Link to this page

Authority KeyName Variants
89477ae4-7b13-474f-a637-b66452884f37
  • Ivanović, Jovana (3)
Projects

Author's Bibliography

Design procedures for cold-formed stainless steel built-up columns assembled from equal-leg angles

Dobrić, Jelena; Gluhović, Nina; Ivanović, Jovana; Rossi, Barbara

(Elsevier, 2023)

TY  - JOUR
AU  - Dobrić, Jelena
AU  - Gluhović, Nina
AU  - Ivanović, Jovana
AU  - Rossi, Barbara
PY  - 2023
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/3257
AB  - In this paper, the structural behaviour of cold-formed stainless steel (CFSS) built-up T- and cruciform-section columns is studied experimentally and numerically, and the effect of discrete fasteners on their flexural and torsional rigidity is considered. To build the singly symmetrical built-up T-section columns, two equal-leg angle sections made of lean-duplex grade EN 1.4162 were assembled back-to-back. The doubly symmetrical built-up cruciform-section columns were composed of four star-oriented equal-leg angle sections made of austenitic grade EN 1.4301. They were connected using M8 bolts of class 8.8. Two pin-ended built-up T-section columns with length of 1000 mm, and four built-up cruciform-section columns with lengths of 600 mm and 2400 mm with semi-rigid support conditions, were tested under pure axial compression. As observed in the tests, built-up T-section columns experienced flexural-torsional buckling failure, whereas built-up cruciform-section columns failed in torsional buckling mode. Finite element models were validated against the conducted experiments and used to perform a parametric study of the structural behaviour of CFSS built-up T- and cruciform-section columns. The study included the column length, cross-sectional dimensions and bolt spacing as variables. The experimental and numerical data, i.e., the column strengths and failure modes, were compared against the results obtained based on the European and North American Specifications alongside a recent method established for cold-formed carbon steel equivalents and based on the Direct Strength Method (DSM). It is shown that the DSM-based approach predicts the ultimate buckling resistances of the considered built-up columns more accurately than the available codified design methods.
PB  - Elsevier
T2  - Journal of Constructional Steel Research
T1  - Design procedures for cold-formed stainless steel built-up columns assembled from equal-leg angles
VL  - 212
DO  - 10.1016/j.jcsr.2023.108263
ER  - 
@article{
author = "Dobrić, Jelena and Gluhović, Nina and Ivanović, Jovana and Rossi, Barbara",
year = "2023",
abstract = "In this paper, the structural behaviour of cold-formed stainless steel (CFSS) built-up T- and cruciform-section columns is studied experimentally and numerically, and the effect of discrete fasteners on their flexural and torsional rigidity is considered. To build the singly symmetrical built-up T-section columns, two equal-leg angle sections made of lean-duplex grade EN 1.4162 were assembled back-to-back. The doubly symmetrical built-up cruciform-section columns were composed of four star-oriented equal-leg angle sections made of austenitic grade EN 1.4301. They were connected using M8 bolts of class 8.8. Two pin-ended built-up T-section columns with length of 1000 mm, and four built-up cruciform-section columns with lengths of 600 mm and 2400 mm with semi-rigid support conditions, were tested under pure axial compression. As observed in the tests, built-up T-section columns experienced flexural-torsional buckling failure, whereas built-up cruciform-section columns failed in torsional buckling mode. Finite element models were validated against the conducted experiments and used to perform a parametric study of the structural behaviour of CFSS built-up T- and cruciform-section columns. The study included the column length, cross-sectional dimensions and bolt spacing as variables. The experimental and numerical data, i.e., the column strengths and failure modes, were compared against the results obtained based on the European and North American Specifications alongside a recent method established for cold-formed carbon steel equivalents and based on the Direct Strength Method (DSM). It is shown that the DSM-based approach predicts the ultimate buckling resistances of the considered built-up columns more accurately than the available codified design methods.",
publisher = "Elsevier",
journal = "Journal of Constructional Steel Research",
title = "Design procedures for cold-formed stainless steel built-up columns assembled from equal-leg angles",
volume = "212",
doi = "10.1016/j.jcsr.2023.108263"
}
Dobrić, J., Gluhović, N., Ivanović, J.,& Rossi, B.. (2023). Design procedures for cold-formed stainless steel built-up columns assembled from equal-leg angles. in Journal of Constructional Steel Research
Elsevier., 212.
https://doi.org/10.1016/j.jcsr.2023.108263
Dobrić J, Gluhović N, Ivanović J, Rossi B. Design procedures for cold-formed stainless steel built-up columns assembled from equal-leg angles. in Journal of Constructional Steel Research. 2023;212.
doi:10.1016/j.jcsr.2023.108263 .
Dobrić, Jelena, Gluhović, Nina, Ivanović, Jovana, Rossi, Barbara, "Design procedures for cold-formed stainless steel built-up columns assembled from equal-leg angles" in Journal of Constructional Steel Research, 212 (2023),
https://doi.org/10.1016/j.jcsr.2023.108263 . .
2

Behaviour of stainless steel plain channel section columns

Dobrić, Jelena; Ivanović, Jovana; Rossi, Barbara

(2020)

TY  - JOUR
AU  - Dobrić, Jelena
AU  - Ivanović, Jovana
AU  - Rossi, Barbara
PY  - 2020
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/2098
AB  - In  this  paper,  the  structural  stability  of  cold-formed  stainless  steel  plain  channel  columns  under  axial compression is investigated. Reliable finite element models for channel section columns are first developed and validated  against  experiments  conducted  on  stainless  steel  lipped  channel  specimens.  This  is  followed  by  a parametric  study  in  which  columns  made  of  austenitic,  ferritic  and  duplex  stainless  steel  are  assessed.  The considered cross-section classes and column lengths cover the entire range of global slenderness. The effects of 
material and geometrical nonlinearity are considered in the numerical analysis. The numerically generated data are then employed to evaluate the accuracy of the current European and Australian design codes EN 1993-1-4 and AS/NZS  4673  respectively, for predicting the flexural and flexural-torsional column buckling resistance. The results show a necessity to improve the current buckling curve used to predict the flexural buckling resistance of plain channel section columns, currently adopted in EN 1993-1-4, whose use may lead to unsafe predictions, especially for the austenitic grade.
T2  - Thin-Walled Structures
T1  - Behaviour of stainless steel plain channel section columns
VL  - 148
DO  - https://doi.org/10.1016/j.tws.2020.106600
ER  - 
@article{
author = "Dobrić, Jelena and Ivanović, Jovana and Rossi, Barbara",
year = "2020",
abstract = "In  this  paper,  the  structural  stability  of  cold-formed  stainless  steel  plain  channel  columns  under  axial compression is investigated. Reliable finite element models for channel section columns are first developed and validated  against  experiments  conducted  on  stainless  steel  lipped  channel  specimens.  This  is  followed  by  a parametric  study  in  which  columns  made  of  austenitic,  ferritic  and  duplex  stainless  steel  are  assessed.  The considered cross-section classes and column lengths cover the entire range of global slenderness. The effects of 
material and geometrical nonlinearity are considered in the numerical analysis. The numerically generated data are then employed to evaluate the accuracy of the current European and Australian design codes EN 1993-1-4 and AS/NZS  4673  respectively, for predicting the flexural and flexural-torsional column buckling resistance. The results show a necessity to improve the current buckling curve used to predict the flexural buckling resistance of plain channel section columns, currently adopted in EN 1993-1-4, whose use may lead to unsafe predictions, especially for the austenitic grade.",
journal = "Thin-Walled Structures",
title = "Behaviour of stainless steel plain channel section columns",
volume = "148",
doi = "https://doi.org/10.1016/j.tws.2020.106600"
}
Dobrić, J., Ivanović, J.,& Rossi, B.. (2020). Behaviour of stainless steel plain channel section columns. in Thin-Walled Structures, 148.
https://doi.org/https://doi.org/10.1016/j.tws.2020.106600
Dobrić J, Ivanović J, Rossi B. Behaviour of stainless steel plain channel section columns. in Thin-Walled Structures. 2020;148.
doi:https://doi.org/10.1016/j.tws.2020.106600 .
Dobrić, Jelena, Ivanović, Jovana, Rossi, Barbara, "Behaviour of stainless steel plain channel section columns" in Thin-Walled Structures, 148 (2020),
https://doi.org/https://doi.org/10.1016/j.tws.2020.106600 . .

A method of determining parameters of Bofang model on the example of "Bileca" reservoir

Mirković, Uroš; Ivanović, Jovana; Pavić, Maja; Radovanović, Slobodan; Mirković, Nikola; Gospavić, Radovan; Todorović, Goran

(Građevinski fakultet Subotica, 2019)

TY  - CONF
AU  - Mirković, Uroš
AU  - Ivanović, Jovana
AU  - Pavić, Maja
AU  - Radovanović, Slobodan
AU  - Mirković, Nikola
AU  - Gospavić, Radovan
AU  - Todorović, Goran
PY  - 2019
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/2790
AB  - In this research paper, measurement data of air and water temperatures and 
water levels for "Bileca" reservoir for a period between 1967. and 2017. are presented. 
Based on the averaged measurement data values, an analytical expressions for amplitude 
of periodic temperature variation of "Bileca" reservoir are derived and an average annual 
temperature, as a function of the observed depth, is obtained, based on Bofang model. The 
obtained results allow thermal stress analysis, which represents an important factor for 
stability and safety monitoring of dams.
PB  - Građevinski fakultet Subotica
C3  - Zbornik radova 7. Međunarodne konferencije - Savremena dostignuća u građevinarstvu 2019
T1  - A method of determining parameters of Bofang model on the example of "Bileca" reservoir
EP  - 705
SP  - 695
DO  - 10.14415/konferencijaGFS2019.064
ER  - 
@conference{
author = "Mirković, Uroš and Ivanović, Jovana and Pavić, Maja and Radovanović, Slobodan and Mirković, Nikola and Gospavić, Radovan and Todorović, Goran",
year = "2019",
abstract = "In this research paper, measurement data of air and water temperatures and 
water levels for "Bileca" reservoir for a period between 1967. and 2017. are presented. 
Based on the averaged measurement data values, an analytical expressions for amplitude 
of periodic temperature variation of "Bileca" reservoir are derived and an average annual 
temperature, as a function of the observed depth, is obtained, based on Bofang model. The 
obtained results allow thermal stress analysis, which represents an important factor for 
stability and safety monitoring of dams.",
publisher = "Građevinski fakultet Subotica",
journal = "Zbornik radova 7. Međunarodne konferencije - Savremena dostignuća u građevinarstvu 2019",
title = "A method of determining parameters of Bofang model on the example of "Bileca" reservoir",
pages = "705-695",
doi = "10.14415/konferencijaGFS2019.064"
}
Mirković, U., Ivanović, J., Pavić, M., Radovanović, S., Mirković, N., Gospavić, R.,& Todorović, G.. (2019). A method of determining parameters of Bofang model on the example of "Bileca" reservoir. in Zbornik radova 7. Međunarodne konferencije - Savremena dostignuća u građevinarstvu 2019
Građevinski fakultet Subotica., 695-705.
https://doi.org/10.14415/konferencijaGFS2019.064
Mirković U, Ivanović J, Pavić M, Radovanović S, Mirković N, Gospavić R, Todorović G. A method of determining parameters of Bofang model on the example of "Bileca" reservoir. in Zbornik radova 7. Međunarodne konferencije - Savremena dostignuća u građevinarstvu 2019. 2019;:695-705.
doi:10.14415/konferencijaGFS2019.064 .
Mirković, Uroš, Ivanović, Jovana, Pavić, Maja, Radovanović, Slobodan, Mirković, Nikola, Gospavić, Radovan, Todorović, Goran, "A method of determining parameters of Bofang model on the example of "Bileca" reservoir" in Zbornik radova 7. Međunarodne konferencije - Savremena dostignuća u građevinarstvu 2019 (2019):695-705,
https://doi.org/10.14415/konferencijaGFS2019.064 . .