Wat-Qual - Water Quality in Drinking Water Distribution Systems. (EU-778136)

Link to this page

Wat-Qual - Water Quality in Drinking Water Distribution Systems. (EU-778136)

Authors

Publications

Optimizacija postupka ispiranja vodovodne mreže

Ivetić, Damjan; Vasilić, Željko

(19. Savetovanje SDHI i SDH, Niš, Srbija, 2021, 2021)

TY  - CONF
AU  - Ivetić, Damjan
AU  - Vasilić, Željko
PY  - 2021
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/2511
AB  - Ispiranje vodovodne mreže se sprovodi nakon što se za određeni deo mreže, ili zone za ispiranje, ustanovi da je voda izložena visokom riziku od zamućenja (promene boje). Uobičajeno se planiranje ispiranja sprovodi ručno i u većini slučajeva predstavlja dugotrajan postupak. Za definisanje plana ispiranja određene zone mreže, neophodno je napraviti skup uzastopnih poteznih ispiranja kojim se ceo deo mreže ispira. U svakom poteznom ispiranju se ispira deo sekundarne (i tercijarne) mreže. Za svako potezno ispiranje potrebno je uz pomoć niza manipulacija zatvaračima na mreži, usmeriti tok vode od fronta čiste vode ka ispustnom hidrantu. Frontovi čiste vode predstavljaju granice dela mreže koji je okarakterisan kao „čist“. Mogu se definisati kroz merenje mutnoće na licu mesta, ili nakon ispiranja konkretnog čvora (odnosno dela mreže u kom se nalazi čvor). Tokom ispiranja cevi, tok vode koji se koristi za ispiranje, mora da ispuni određen skup hidrauličkih kriterijuma, kako bi se promena mutnoće vode, ili zagađenje, adekvatno otklonilo. Sa stanovišta nadležnog komunalnog preduzeća, plan ispiranja mreže treba da bude ekonomičan u pogledu minimalnog utroška vremena i resursa (npr pijaće vode) za njegovu implementaciju. U ovom radu, mogućnost automatizacije i optimizacije planiranja ispiranja, uz pomoć novo razvijenog FPA (eng. Flashing Planning Algorithm) algoritma je testirana i analizirana. FPA algoritam je napravljen kako bi na adekvatan način odgovorio na gore navedene zahteve.
AB  - Flushing of the drinking water distribution systems is conducted after a certain part of the water distribution network, or the flushing zone, is identified to be a subject to a high risk of discoloration. Typically, flushing planning is performed manually and is usually time-consuming. To derive a flushing plan for a flushing zone, a set of sequential flushing operations needs to be defined. In each flushing operation the parts of the secondary and tertiary network, meeting multiple criterion, will be flushed. For each flushing operation a set of valves manipulations is needed to converge the water flow, from a clearwater front, through the pipes that are set to be flushed, and out of the system via output hydrant. Clearwater fronts are network nodes on the boundary of the network which is deemed as “clean”. They can be defined through in-situ turbidity measurements, or after the actual flushing of the node (part of the network containing the node). To perform the pipe flushing, the water flow used to flush a pipe, needs to meet a set of hydraulic criteria, in order to allow for the discoloration to be appropriately addressed and removed. From the water utility perspective, the flushing plan should be economical in terms of the minimal expenditure of the time and resources (e.g. drinking water) for the implementation. Here, a possibility for the automatization of the flushing planning with the newly developed FPA (Flushing Planning Algorithm) algorithm, was tested and analyzed. The FPA algorithm was designed to address the flushing planning by taking into the account all the above-mentioned criteria.
PB  - 19. Savetovanje SDHI i SDH, Niš, Srbija, 2021
C3  - 19. Savetovanje SDHI i SDH, Niš, Srbija, 2021
T1  - Optimizacija postupka ispiranja vodovodne mreže
T1  - Optimization of the water distribution network flushing
UR  - https://hdl.handle.net/21.15107/rcub_grafar_2511
ER  - 
@conference{
author = "Ivetić, Damjan and Vasilić, Željko",
year = "2021",
abstract = "Ispiranje vodovodne mreže se sprovodi nakon što se za određeni deo mreže, ili zone za ispiranje, ustanovi da je voda izložena visokom riziku od zamućenja (promene boje). Uobičajeno se planiranje ispiranja sprovodi ručno i u većini slučajeva predstavlja dugotrajan postupak. Za definisanje plana ispiranja određene zone mreže, neophodno je napraviti skup uzastopnih poteznih ispiranja kojim se ceo deo mreže ispira. U svakom poteznom ispiranju se ispira deo sekundarne (i tercijarne) mreže. Za svako potezno ispiranje potrebno je uz pomoć niza manipulacija zatvaračima na mreži, usmeriti tok vode od fronta čiste vode ka ispustnom hidrantu. Frontovi čiste vode predstavljaju granice dela mreže koji je okarakterisan kao „čist“. Mogu se definisati kroz merenje mutnoće na licu mesta, ili nakon ispiranja konkretnog čvora (odnosno dela mreže u kom se nalazi čvor). Tokom ispiranja cevi, tok vode koji se koristi za ispiranje, mora da ispuni određen skup hidrauličkih kriterijuma, kako bi se promena mutnoće vode, ili zagađenje, adekvatno otklonilo. Sa stanovišta nadležnog komunalnog preduzeća, plan ispiranja mreže treba da bude ekonomičan u pogledu minimalnog utroška vremena i resursa (npr pijaće vode) za njegovu implementaciju. U ovom radu, mogućnost automatizacije i optimizacije planiranja ispiranja, uz pomoć novo razvijenog FPA (eng. Flashing Planning Algorithm) algoritma je testirana i analizirana. FPA algoritam je napravljen kako bi na adekvatan način odgovorio na gore navedene zahteve., Flushing of the drinking water distribution systems is conducted after a certain part of the water distribution network, or the flushing zone, is identified to be a subject to a high risk of discoloration. Typically, flushing planning is performed manually and is usually time-consuming. To derive a flushing plan for a flushing zone, a set of sequential flushing operations needs to be defined. In each flushing operation the parts of the secondary and tertiary network, meeting multiple criterion, will be flushed. For each flushing operation a set of valves manipulations is needed to converge the water flow, from a clearwater front, through the pipes that are set to be flushed, and out of the system via output hydrant. Clearwater fronts are network nodes on the boundary of the network which is deemed as “clean”. They can be defined through in-situ turbidity measurements, or after the actual flushing of the node (part of the network containing the node). To perform the pipe flushing, the water flow used to flush a pipe, needs to meet a set of hydraulic criteria, in order to allow for the discoloration to be appropriately addressed and removed. From the water utility perspective, the flushing plan should be economical in terms of the minimal expenditure of the time and resources (e.g. drinking water) for the implementation. Here, a possibility for the automatization of the flushing planning with the newly developed FPA (Flushing Planning Algorithm) algorithm, was tested and analyzed. The FPA algorithm was designed to address the flushing planning by taking into the account all the above-mentioned criteria.",
publisher = "19. Savetovanje SDHI i SDH, Niš, Srbija, 2021",
journal = "19. Savetovanje SDHI i SDH, Niš, Srbija, 2021",
title = "Optimizacija postupka ispiranja vodovodne mreže, Optimization of the water distribution network flushing",
url = "https://hdl.handle.net/21.15107/rcub_grafar_2511"
}
Ivetić, D.,& Vasilić, Ž.. (2021). Optimizacija postupka ispiranja vodovodne mreže. in 19. Savetovanje SDHI i SDH, Niš, Srbija, 2021
19. Savetovanje SDHI i SDH, Niš, Srbija, 2021..
https://hdl.handle.net/21.15107/rcub_grafar_2511
Ivetić D, Vasilić Ž. Optimizacija postupka ispiranja vodovodne mreže. in 19. Savetovanje SDHI i SDH, Niš, Srbija, 2021. 2021;.
https://hdl.handle.net/21.15107/rcub_grafar_2511 .
Ivetić, Damjan, Vasilić, Željko, "Optimizacija postupka ispiranja vodovodne mreže" in 19. Savetovanje SDHI i SDH, Niš, Srbija, 2021 (2021),
https://hdl.handle.net/21.15107/rcub_grafar_2511 .

Report on Flushing Planning Algorithm testing on the flushing zones of the drinking water distribution system of the city of Amsterdam

Ivetić, Damjan; Vasilić, Željko

(University of Sheffield, 2020)

TY  - RPRT
AU  - Ivetić, Damjan
AU  - Vasilić, Željko
PY  - 2020
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/2515
AB  - This report describes the development of the Flushing Planning Algorithm (FPA) for deriving flushing plans to address discolouration in drinking water distribution systems. The application of the FPA to the water system serving Amsterdam, Netherlands (Waternet), is presented.
PB  - University of Sheffield
T2  - University of Sheffield
T1  - Report on Flushing Planning Algorithm testing on the flushing zones of the drinking water distribution system of the city of Amsterdam
UR  - https://hdl.handle.net/21.15107/rcub_grafar_2515
ER  - 
@techreport{
author = "Ivetić, Damjan and Vasilić, Željko",
year = "2020",
abstract = "This report describes the development of the Flushing Planning Algorithm (FPA) for deriving flushing plans to address discolouration in drinking water distribution systems. The application of the FPA to the water system serving Amsterdam, Netherlands (Waternet), is presented.",
publisher = "University of Sheffield",
journal = "University of Sheffield",
title = "Report on Flushing Planning Algorithm testing on the flushing zones of the drinking water distribution system of the city of Amsterdam",
url = "https://hdl.handle.net/21.15107/rcub_grafar_2515"
}
Ivetić, D.,& Vasilić, Ž.. (2020). Report on Flushing Planning Algorithm testing on the flushing zones of the drinking water distribution system of the city of Amsterdam. in University of Sheffield
University of Sheffield..
https://hdl.handle.net/21.15107/rcub_grafar_2515
Ivetić D, Vasilić Ž. Report on Flushing Planning Algorithm testing on the flushing zones of the drinking water distribution system of the city of Amsterdam. in University of Sheffield. 2020;.
https://hdl.handle.net/21.15107/rcub_grafar_2515 .
Ivetić, Damjan, Vasilić, Željko, "Report on Flushing Planning Algorithm testing on the flushing zones of the drinking water distribution system of the city of Amsterdam" in University of Sheffield (2020),
https://hdl.handle.net/21.15107/rcub_grafar_2515 .