Problems of floor slab design in terms of capacity, safety and energy efficiency

Problematika projektovanja međuspratnih ploča sa aspekta nosivosti, sigurnosti i energetske efikasnosti

Thumbnail
2017
1544.pdf (1.244Mb)
Authors
Kekanović, Milan
Šumarac, Dragoslav
Ćorić, Stanko
Kasaš, Karolj
Čeh, Arpad
Conference object (Published version)
Metadata
Show full item record
Abstract
This article provides information about the possibilities of design and construction floor slabs concerning three very important aspects: the capacity, safety and energy efficiency.Nowadays, in the Republic of Serbia exclusively solid concrete slabs are designed and built,which are at least 20cm thick.The justification for this solution is to obtain, in its plane, a rigid plate-diaphragm that is able to endure seismic forces on the walls, proportionally to the stiffness of those walls.At the same time this solution has many disadvantages and it is a great load that limits the length of the span. That heavy load is directly proportional to the size of the seismic forces. The20 cm thick, solid concrete slab has a large heat capacity, and specific heat c (J / kgK), which are not energy efficient,as the warm air is accumulated, conductedtowards to the walls and also retained near the ceiling, while people are near the floor.There are other solutions of design and construction floor slabs t...hat meet demands far more than a solid concrete slab.These are the reinforced concrete site-cast waffle slab.These slabs are extremely stiff and stable, optionally in both directions and can have a reduced mass up to 50% compared with solid concrete slabs.The authors will introduce one waffle-slab solution of reinforced concrete slabs, which satisfies, in addition to above mentioned, even the energy efficiency demand. It is a solution by Stirofert-technology built with structural expanded polystyrene as a stay-in-place formwork during the phase of concrete pouring and construction. This same stay-in-place formwork is a powerful insulation on ceiling with a preventing effect against heat-accumulation and heat losses towards the walls; same time equalizing the temperature of air near the floor and ceiling.

Source:
Zbornik radova 5. međunarodne konferencije Savremena dostignuća u građevinarstvu 2017, 2017, 33, 729-738
Publisher:
  • Građevinski fakultet, Subotica
Funding / projects:
  • Energy efficiency enhancement of buildings in Serbia and improvement of national regulative capacity for they are certification (RS-42012)
Note:
  • Zbornik radova Građevinskog fakulteta

DOI: 10.14415/konferencijaGFS2017.077

[ Google Scholar ]
URI
https://grafar.grf.bg.ac.rs/handle/123456789/1546
Collections
  • Radovi istraživača / Researcher's publications
  • Катедра за техничку механику и теорију конструкција
Institution/Community
GraFar
TY  - CONF
AU  - Kekanović, Milan
AU  - Šumarac, Dragoslav
AU  - Ćorić, Stanko
AU  - Kasaš, Karolj
AU  - Čeh, Arpad
PY  - 2017
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/1546
AB  - This article provides information about the possibilities of design and construction floor slabs concerning three very important aspects: the capacity, safety and energy efficiency.Nowadays, in the Republic of Serbia exclusively solid concrete slabs are designed and built,which are at least 20cm thick.The justification for this solution is to obtain, in its plane, a rigid plate-diaphragm that is able to endure seismic forces on the walls, proportionally to the stiffness of those walls.At the same time this solution has many disadvantages and it is a great load that limits the length of the span. That heavy load is directly proportional to the size of the seismic forces. The20 cm thick, solid concrete slab has a large heat capacity, and specific heat c (J / kgK), which are not energy efficient,as the warm air is accumulated, conductedtowards to the walls and also retained near the ceiling, while people are near the floor.There are other solutions of design and construction floor slabs that meet demands far more than a solid concrete slab.These are the reinforced concrete site-cast waffle slab.These slabs are extremely stiff and stable, optionally in both directions and can have a reduced mass up to 50% compared with solid concrete slabs.The authors will introduce one waffle-slab solution of reinforced concrete slabs, which satisfies, in addition to above mentioned, even the energy efficiency demand. It is a solution by Stirofert-technology built with structural expanded polystyrene as a stay-in-place formwork during the phase of concrete pouring and construction. This same stay-in-place formwork is a powerful insulation on ceiling with a preventing effect against heat-accumulation and heat losses towards the walls; same time equalizing the temperature of air near the floor and ceiling.
PB  - Građevinski fakultet, Subotica
C3  - Zbornik radova 5. međunarodne konferencije Savremena dostignuća u građevinarstvu 2017
T1  - Problems of floor slab design in terms of capacity, safety and energy efficiency
T1  - Problematika projektovanja međuspratnih ploča sa aspekta nosivosti, sigurnosti i energetske efikasnosti
EP  - 738
SP  - 729
VL  - 33
DO  - 10.14415/konferencijaGFS2017.077
UR  - conv_4106
ER  - 
@conference{
author = "Kekanović, Milan and Šumarac, Dragoslav and Ćorić, Stanko and Kasaš, Karolj and Čeh, Arpad",
year = "2017",
abstract = "This article provides information about the possibilities of design and construction floor slabs concerning three very important aspects: the capacity, safety and energy efficiency.Nowadays, in the Republic of Serbia exclusively solid concrete slabs are designed and built,which are at least 20cm thick.The justification for this solution is to obtain, in its plane, a rigid plate-diaphragm that is able to endure seismic forces on the walls, proportionally to the stiffness of those walls.At the same time this solution has many disadvantages and it is a great load that limits the length of the span. That heavy load is directly proportional to the size of the seismic forces. The20 cm thick, solid concrete slab has a large heat capacity, and specific heat c (J / kgK), which are not energy efficient,as the warm air is accumulated, conductedtowards to the walls and also retained near the ceiling, while people are near the floor.There are other solutions of design and construction floor slabs that meet demands far more than a solid concrete slab.These are the reinforced concrete site-cast waffle slab.These slabs are extremely stiff and stable, optionally in both directions and can have a reduced mass up to 50% compared with solid concrete slabs.The authors will introduce one waffle-slab solution of reinforced concrete slabs, which satisfies, in addition to above mentioned, even the energy efficiency demand. It is a solution by Stirofert-technology built with structural expanded polystyrene as a stay-in-place formwork during the phase of concrete pouring and construction. This same stay-in-place formwork is a powerful insulation on ceiling with a preventing effect against heat-accumulation and heat losses towards the walls; same time equalizing the temperature of air near the floor and ceiling.",
publisher = "Građevinski fakultet, Subotica",
journal = "Zbornik radova 5. međunarodne konferencije Savremena dostignuća u građevinarstvu 2017",
title = "Problems of floor slab design in terms of capacity, safety and energy efficiency, Problematika projektovanja međuspratnih ploča sa aspekta nosivosti, sigurnosti i energetske efikasnosti",
pages = "738-729",
volume = "33",
doi = "10.14415/konferencijaGFS2017.077",
url = "conv_4106"
}
Kekanović, M., Šumarac, D., Ćorić, S., Kasaš, K.,& Čeh, A.. (2017). Problems of floor slab design in terms of capacity, safety and energy efficiency. in Zbornik radova 5. međunarodne konferencije Savremena dostignuća u građevinarstvu 2017
Građevinski fakultet, Subotica., 33, 729-738.
https://doi.org/10.14415/konferencijaGFS2017.077
conv_4106
Kekanović M, Šumarac D, Ćorić S, Kasaš K, Čeh A. Problems of floor slab design in terms of capacity, safety and energy efficiency. in Zbornik radova 5. međunarodne konferencije Savremena dostignuća u građevinarstvu 2017. 2017;33:729-738.
doi:10.14415/konferencijaGFS2017.077
conv_4106 .
Kekanović, Milan, Šumarac, Dragoslav, Ćorić, Stanko, Kasaš, Karolj, Čeh, Arpad, "Problems of floor slab design in terms of capacity, safety and energy efficiency" in Zbornik radova 5. međunarodne konferencije Savremena dostignuća u građevinarstvu 2017, 33 (2017):729-738,
https://doi.org/10.14415/konferencijaGFS2017.077 .,
conv_4106 .

DSpace software copyright © 2002-2015  DuraSpace
About the GraFar Repository | Send Feedback

OpenAIRERCUB
 

 

All of DSpaceInstitutions/communitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About the GraFar Repository | Send Feedback

OpenAIRERCUB