GraFar - Repository of the Faculty of Civil Engineering
Faculty of Civil Engineering of the University of Belgrade
    • English
    • Српски
    • Српски (Serbia)
  • English 
    • English
    • Serbian (Cyrillic)
    • Serbian (Latin)
  • Login
View Item 
  •   GraFar
  • GraFar
  • Radovi istraživača / Researcher's publications
  • View Item
  •   GraFar
  • GraFar
  • Radovi istraživača / Researcher's publications
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Bed-mounted Electro Magnetic meters: Implications for robust velocity measurement in Urban Drainage systems

Thumbnail
2018
10.1016-j.jhydrol.2018.08.068.pdf (2.216Mb)
Authors
Ivetić, Damjan
Prodanović, Dušan
Stojadinović, Luka
Article (Accepted Version)
Metadata
Show full item record
Abstract
Flow monitoring in Urban Drainage Systems (UDS) is required for a successful system control and operational assessment. Commonly used methods can lead to erroneous results in partially filled pipes and hostile environmental conditions, normally encountered in UDS. Recent studies focused on the flow rate measurements in UDS revealed that the capability of acoustic Doppler velocimeters to estimate mean flow velocity is impeded by several factors. Most prominent issues are the operation under low flow depths and velocities, as well as in the case of the sedimentation at low flow velocities. This study is focused on an alternative method for the velocity measurements in the UDS, based on Electro-Magnetic Velocity (EMV) meters. The study also determines the sensor's capacity to operate when covered by a porous sediment layer, using a newly developed procedure. A brief theoretical background is given to support the idea behind the usage of EMV in UDS. Measurement uncertainties were firstly b...enchmarked in the laboratory flume without sediment. After local, site-specific (re) calibration, EMV operated with combined uncertainty of only few cm/s. Furthermore, the EMV measured the flow rates with depths low as 4 cm and velocities bellow 5 cm/s. Additionally, a series of tests were performed with sediment layers above the EMV meter, varying in height from 0 to 80 mm. Observational uncertainty analysis showed that EMV meter can be used even in these conditions. Since the bias uncertainty increased with the rise of the sediment depth, a correction function model was derived for the transformation of the output signal, reducing the observational uncertainties below 5 cm/s. Subsequently, practical implications of the EMV usage in the UDS are considered.

Keywords:
Velocity measurements / Urban Drainage Systems / Sedimentation / Electro Magnetic Velocity meters / Uncertainty / Laboratory test
Source:
Journal of Hydrology, 2018, 566, 455-469
Publisher:
  • Elsevier B.V.
Funding / projects:
  • Urban Drainage Systems as Key Infrastructure in Cities and Towns (RS-37010)
Note:
  • This is the peer-reviewed version of the article: Ivetić, D., Prodanović, D., Stojadinović, L., 2018. Bed-mounted Electro Magnetic meters: Implications for robust velocity measurement in Urban Drainage systems. Journal of Hydrology 566, 455–469. https://doi.org/10.1016/j.jhydrol.2018.08.068

DOI: 10.1016/j.jhydrol.2018.08.068

ISSN: 0022-1694

WoS: 000449901100035

Scopus: 2-s2.0-85053792973
[ Google Scholar ]
1
1
URI
https://grafar.grf.bg.ac.rs/handle/123456789/1708
Collections
  • Radovi istraživača / Researcher's publications
  • Катедра за хидротехнику и водно-еколошко инжењерство
Institution/Community
GraFar
TY  - JOUR
AU  - Ivetić, Damjan
AU  - Prodanović, Dušan
AU  - Stojadinović, Luka
PY  - 2018
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/1708
AB  - Flow monitoring in Urban Drainage Systems (UDS) is required for a successful system control and operational assessment. Commonly used methods can lead to erroneous results in partially filled pipes and hostile environmental conditions, normally encountered in UDS. Recent studies focused on the flow rate measurements in UDS revealed that the capability of acoustic Doppler velocimeters to estimate mean flow velocity is impeded by several factors. Most prominent issues are the operation under low flow depths and velocities, as well as in the case of the sedimentation at low flow velocities. This study is focused on an alternative method for the velocity measurements in the UDS, based on Electro-Magnetic Velocity (EMV) meters. The study also determines the sensor's capacity to operate when covered by a porous sediment layer, using a newly developed procedure. A brief theoretical background is given to support the idea behind the usage of EMV in UDS. Measurement uncertainties were firstly benchmarked in the laboratory flume without sediment. After local, site-specific (re) calibration, EMV operated with combined uncertainty of only few cm/s. Furthermore, the EMV measured the flow rates with depths low as 4 cm and velocities bellow 5 cm/s. Additionally, a series of tests were performed with sediment layers above the EMV meter, varying in height from 0 to 80 mm. Observational uncertainty analysis showed that EMV meter can be used even in these conditions. Since the bias uncertainty increased with the rise of the sediment depth, a correction function model was derived for the transformation of the output signal, reducing the observational uncertainties below 5 cm/s. Subsequently, practical implications of the EMV usage in the UDS are considered.
PB  - Elsevier B.V.
T2  - Journal of Hydrology
T1  - Bed-mounted Electro Magnetic meters: Implications for robust velocity measurement in Urban Drainage systems
EP  - 469
SP  - 455
VL  - 566
DO  - 10.1016/j.jhydrol.2018.08.068
UR  - conv_2009
ER  - 
@article{
author = "Ivetić, Damjan and Prodanović, Dušan and Stojadinović, Luka",
year = "2018",
abstract = "Flow monitoring in Urban Drainage Systems (UDS) is required for a successful system control and operational assessment. Commonly used methods can lead to erroneous results in partially filled pipes and hostile environmental conditions, normally encountered in UDS. Recent studies focused on the flow rate measurements in UDS revealed that the capability of acoustic Doppler velocimeters to estimate mean flow velocity is impeded by several factors. Most prominent issues are the operation under low flow depths and velocities, as well as in the case of the sedimentation at low flow velocities. This study is focused on an alternative method for the velocity measurements in the UDS, based on Electro-Magnetic Velocity (EMV) meters. The study also determines the sensor's capacity to operate when covered by a porous sediment layer, using a newly developed procedure. A brief theoretical background is given to support the idea behind the usage of EMV in UDS. Measurement uncertainties were firstly benchmarked in the laboratory flume without sediment. After local, site-specific (re) calibration, EMV operated with combined uncertainty of only few cm/s. Furthermore, the EMV measured the flow rates with depths low as 4 cm and velocities bellow 5 cm/s. Additionally, a series of tests were performed with sediment layers above the EMV meter, varying in height from 0 to 80 mm. Observational uncertainty analysis showed that EMV meter can be used even in these conditions. Since the bias uncertainty increased with the rise of the sediment depth, a correction function model was derived for the transformation of the output signal, reducing the observational uncertainties below 5 cm/s. Subsequently, practical implications of the EMV usage in the UDS are considered.",
publisher = "Elsevier B.V.",
journal = "Journal of Hydrology",
title = "Bed-mounted Electro Magnetic meters: Implications for robust velocity measurement in Urban Drainage systems",
pages = "469-455",
volume = "566",
doi = "10.1016/j.jhydrol.2018.08.068",
url = "conv_2009"
}
Ivetić, D., Prodanović, D.,& Stojadinović, L.. (2018). Bed-mounted Electro Magnetic meters: Implications for robust velocity measurement in Urban Drainage systems. in Journal of Hydrology
Elsevier B.V.., 566, 455-469.
https://doi.org/10.1016/j.jhydrol.2018.08.068
conv_2009
Ivetić D, Prodanović D, Stojadinović L. Bed-mounted Electro Magnetic meters: Implications for robust velocity measurement in Urban Drainage systems. in Journal of Hydrology. 2018;566:455-469.
doi:10.1016/j.jhydrol.2018.08.068
conv_2009 .
Ivetić, Damjan, Prodanović, Dušan, Stojadinović, Luka, "Bed-mounted Electro Magnetic meters: Implications for robust velocity measurement in Urban Drainage systems" in Journal of Hydrology, 566 (2018):455-469,
https://doi.org/10.1016/j.jhydrol.2018.08.068 .,
conv_2009 .

DSpace software copyright © 2002-2015  DuraSpace
About the GraFar Repository | Send Feedback

OpenAIRERCUB
 

 

All of DSpaceInstitutions/communitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About the GraFar Repository | Send Feedback

OpenAIRERCUB