Shear resistance of headed shear studs welded on welded plates in composite floors

Samo za registrovane korisnike
2019
Autori
Molkens, Tom
Dobrić, Jelena
Rossi, Barbara
Članak u časopisu (Objavljena verzija)
Metapodaci
Prikaz svih podataka o dokumentu
Apstrakt
The present paper deals with composite steel-concrete floor with headed shear studs welded onto a flat steel plate. In bridges applications, which are the focus of the paper, very thick steel plates are often combined with a moderate layer of concrete. And, in some wide slab applications, the most performant lay-out for the shear studs could lead to them being welded on top of an existing butt weld between steel plates. Presently, we are ignorant about the shear resistance of the weld-to-weld interface and its possible detrimental effect on the overall resistance of the system. In addition, the ultimate behaviour of the system combines the flexural resistance of a composite cross-section followed by, when the concrete is cracked, the development of a compressed arch anchored in these headed shear studs, emphasising the importance of such connections. Both questions are addressed in the paper and, based on experiments, an in-depth analysis on the system’s behaviour at ultimate limit st...ate is provided. Two types of tests are performed: pure shear tests complying to the push-out tests of Annex B of EN 1994-1-1 and beam tests with four-point loading where the studs in the shear spans are loaded with longitudinal shear. For each pair of tests, the reference specimen was made with a steel plate without a butt weld or comprising a butt weld directly under the line of shear studs. Typical floor dimensions from bridge applications are studied. No difference in shear capacity, stiffness or failure mode could be observed. However, it was noticed that the classic design rules provided in EN1994-1-1 cannot accurately predict the failure load of the chosen configuration. Based on assumptions made following the observations of the failure mechanisms, the authors propose a theoretical evaluation of the capacity of the system.

Ključne reči:
Four-point bending tests / Longitudinal shear resistance / Composite floor / Butt weld / Push-out test
Izvor:
Engineering Structures, 2019, 197, 109412, 1-16
Izdavač:
  • Elsevier Ltd.

DOI: 10.1016/j.engstruct.2019.109412

ISSN: 0141-0296

WoS: 000503100200084

Scopus: 2-s2.0-85069975800
[ Google Scholar ]
URI
https://grafar.grf.bg.ac.rs/handle/123456789/1772
Kolekcije
  • Radovi istraživača / Researcher's publications
  • Катедра за материјале и конструкције
Institucija/grupa
GraFar

DSpace software copyright © 2002-2015  DuraSpace
O repozitorijumu GraFar | Pošaljite zapažanja

OpenAIRERCUB
 

 

Kompletan repozitorijumGrupeAutoriNasloviTemeOva institucijaAutoriNasloviTeme

Statistika

Pregled statistika

DSpace software copyright © 2002-2015  DuraSpace
O repozitorijumu GraFar | Pošaljite zapažanja

OpenAIRERCUB