Calibration of the bolt pretension by strain gauges vs. FEA
Само за регистроване кориснике
2015
Конференцијски прилог (Објављена верзија)
,
MASE - Macedonian Association of Structural Engineers Faculty of Civil Engineering, Skopje, Republic of Macedonia
Метаподаци
Приказ свих података о документуАпстракт
When applying high strength bolts in friction connections, in such case a load–bearing capacity depends on a pretension force in the bolts as well as on a friction coefficient found on friction surfaces. It is important to get the reliable value of the pretension force, which is why friction connections often undergo experimental research. In order to use strain gauges, which are inserted into the bolt shank, bolts need to be calibrated before we even use them in experimental research. Research that has been conducted shows a great difference between nominal and experimental strain in bolts, therefore FEA calibration of the bolts had to be carried out. Good results matching were obtained; hence a use of strain gauges was justified even for bolts without a shank.
Кључне речи:
high strength bolts / pretension force / calibration / experiment / FEA / longitudinal strainИзвор:
Proceedings 16th International Symposium Macedonian Association of Structural Engineers, 2015, 483-493Издавач:
- MASE - Macedonian Association of Structural Engineers Faculty of Civil Engineering, Skopje, Republic of Macedonia
Финансирање / пројекти:
- Истраживање стања и метода унапређења грађевинских конструкција са аспекта употребљивости, носивости, економичности и одржавања (RS-MESTD-Technological Development (TD or TR)-36048)
Институција/група
GraFarTY - CONF AU - Fric, Nenad AU - Pavlović, Marko AU - Buđevac, Dragan AU - Mišković, Zoran AU - Marković, Zlatko AU - Gluhović, Nina PY - 2015 UR - https://grafar.grf.bg.ac.rs/handle/123456789/2244 AB - When applying high strength bolts in friction connections, in such case a load–bearing capacity depends on a pretension force in the bolts as well as on a friction coefficient found on friction surfaces. It is important to get the reliable value of the pretension force, which is why friction connections often undergo experimental research. In order to use strain gauges, which are inserted into the bolt shank, bolts need to be calibrated before we even use them in experimental research. Research that has been conducted shows a great difference between nominal and experimental strain in bolts, therefore FEA calibration of the bolts had to be carried out. Good results matching were obtained; hence a use of strain gauges was justified even for bolts without a shank. PB - MASE - Macedonian Association of Structural Engineers Faculty of Civil Engineering, Skopje, Republic of Macedonia C3 - Proceedings 16th International Symposium Macedonian Association of Structural Engineers T1 - Calibration of the bolt pretension by strain gauges vs. FEA EP - 493 SP - 483 UR - https://hdl.handle.net/21.15107/rcub_grafar_2244 ER -
@conference{ author = "Fric, Nenad and Pavlović, Marko and Buđevac, Dragan and Mišković, Zoran and Marković, Zlatko and Gluhović, Nina", year = "2015", abstract = "When applying high strength bolts in friction connections, in such case a load–bearing capacity depends on a pretension force in the bolts as well as on a friction coefficient found on friction surfaces. It is important to get the reliable value of the pretension force, which is why friction connections often undergo experimental research. In order to use strain gauges, which are inserted into the bolt shank, bolts need to be calibrated before we even use them in experimental research. Research that has been conducted shows a great difference between nominal and experimental strain in bolts, therefore FEA calibration of the bolts had to be carried out. Good results matching were obtained; hence a use of strain gauges was justified even for bolts without a shank.", publisher = "MASE - Macedonian Association of Structural Engineers Faculty of Civil Engineering, Skopje, Republic of Macedonia", journal = "Proceedings 16th International Symposium Macedonian Association of Structural Engineers", title = "Calibration of the bolt pretension by strain gauges vs. FEA", pages = "493-483", url = "https://hdl.handle.net/21.15107/rcub_grafar_2244" }
Fric, N., Pavlović, M., Buđevac, D., Mišković, Z., Marković, Z.,& Gluhović, N.. (2015). Calibration of the bolt pretension by strain gauges vs. FEA. in Proceedings 16th International Symposium Macedonian Association of Structural Engineers MASE - Macedonian Association of Structural Engineers Faculty of Civil Engineering, Skopje, Republic of Macedonia., 483-493. https://hdl.handle.net/21.15107/rcub_grafar_2244
Fric N, Pavlović M, Buđevac D, Mišković Z, Marković Z, Gluhović N. Calibration of the bolt pretension by strain gauges vs. FEA. in Proceedings 16th International Symposium Macedonian Association of Structural Engineers. 2015;:483-493. https://hdl.handle.net/21.15107/rcub_grafar_2244 .
Fric, Nenad, Pavlović, Marko, Buđevac, Dragan, Mišković, Zoran, Marković, Zlatko, Gluhović, Nina, "Calibration of the bolt pretension by strain gauges vs. FEA" in Proceedings 16th International Symposium Macedonian Association of Structural Engineers (2015):483-493, https://hdl.handle.net/21.15107/rcub_grafar_2244 .