Experimental investigation of preload losses in high strength bolts under cyclic loading
Abstract
Slip-resistant shear connections with preloaded bolts have traditionally been used in steel
structures exposed to cyclic. Hence, shear load is transferred through friction surfaces
rather than through contact between the bolt surface and the hole. The main influencing
parameters determining slip resistance of the connection are the friction between contact
surfaces and the bolt preload level. This paper presents an experimental study of preloaded
bolted connections under cyclic load, the main objective being to investigate the influence
of cyclic load on the losses of preload force in high strength bolts and lock bolts.
Keywords:
high strength bolt / preload force / preload loss / slip factor / cyclic loadSource:
GRAĐEVINAR, 2021, 73, 5, 453-Funding / projects:
Institution/Community
GraFarTY - JOUR AU - Fric, Nenad AU - Veljković, Milan AU - Mišković, Zoran AU - Budjevac, Dragan PY - 2021 UR - https://grafar.grf.bg.ac.rs/handle/123456789/2388 AB - Slip-resistant shear connections with preloaded bolts have traditionally been used in steel structures exposed to cyclic. Hence, shear load is transferred through friction surfaces rather than through contact between the bolt surface and the hole. The main influencing parameters determining slip resistance of the connection are the friction between contact surfaces and the bolt preload level. This paper presents an experimental study of preloaded bolted connections under cyclic load, the main objective being to investigate the influence of cyclic load on the losses of preload force in high strength bolts and lock bolts. T2 - GRAĐEVINAR T1 - Experimental investigation of preload losses in high strength bolts under cyclic loading IS - 5 SP - 453 SP - 468 VL - 73 DO - 10.14256/JCE.3157.2021 ER -
@article{ author = "Fric, Nenad and Veljković, Milan and Mišković, Zoran and Budjevac, Dragan", year = "2021", abstract = "Slip-resistant shear connections with preloaded bolts have traditionally been used in steel structures exposed to cyclic. Hence, shear load is transferred through friction surfaces rather than through contact between the bolt surface and the hole. The main influencing parameters determining slip resistance of the connection are the friction between contact surfaces and the bolt preload level. This paper presents an experimental study of preloaded bolted connections under cyclic load, the main objective being to investigate the influence of cyclic load on the losses of preload force in high strength bolts and lock bolts.", journal = "GRAĐEVINAR", title = "Experimental investigation of preload losses in high strength bolts under cyclic loading", number = "5", pages = "453-468", volume = "73", doi = "10.14256/JCE.3157.2021" }
Fric, N., Veljković, M., Mišković, Z.,& Budjevac, D.. (2021). Experimental investigation of preload losses in high strength bolts under cyclic loading. in GRAĐEVINAR, 73(5), 453. https://doi.org/10.14256/JCE.3157.2021
Fric N, Veljković M, Mišković Z, Budjevac D. Experimental investigation of preload losses in high strength bolts under cyclic loading. in GRAĐEVINAR. 2021;73(5):453. doi:10.14256/JCE.3157.2021 .
Fric, Nenad, Veljković, Milan, Mišković, Zoran, Budjevac, Dragan, "Experimental investigation of preload losses in high strength bolts under cyclic loading" in GRAĐEVINAR, 73, no. 5 (2021):453, https://doi.org/10.14256/JCE.3157.2021 . .