Determination of the temperature transfer function of building constructions based on measurement data
Конференцијски прилог (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
In this paper a method of determination of transfer function for temperature measured inside and outside residential building in Belgrade is presented. The instantaneous measurements of indoor temperature inside a living room of the second floor flat of the five store building and outdoor temperature at close vicinity of the building facade were made. The external air temperature were also collected from nearby meteorological station few hundred meters apart of the building at the same moments. The measurements have lasted more than three months in period from 22th April till the 2th August. 2014. The data have been collected by data loggers every 5 minutes. Using a digital processing the periodical daily and seasonal variations have been extracted from indoor and outdoor temperature measurements. These variations for indoor and outdoor temperature are considered as excitation and response functions respectively. The periodic outdoor temperature variations could be considered as comple...x periodic excitation. The Z transformation have been adopted to obtain temperature variations in frequent domain and temperature transfer function for the considered building construction.
Извор:
Seventeenth Annual Conference YUCOMAT 2015, Herceg Novi, August 31– September 4, 2015., 04-01-2015, 16Издавач:
- Materials Research Society of Serbia
Колекције
Институција/група
GraFarTY - CONF AU - Petojević, Zorana AU - Mirković, Milica AU - Jovanović, Željko AU - Gospavić, Radovan AU - Todorović, Goran PY - 2015-01-04 UR - https://dais.sanu.ac.rs/123456789/847 UR - https://grafar.grf.bg.ac.rs/handle/123456789/2997 AB - In this paper a method of determination of transfer function for temperature measured inside and outside residential building in Belgrade is presented. The instantaneous measurements of indoor temperature inside a living room of the second floor flat of the five store building and outdoor temperature at close vicinity of the building facade were made. The external air temperature were also collected from nearby meteorological station few hundred meters apart of the building at the same moments. The measurements have lasted more than three months in period from 22th April till the 2th August. 2014. The data have been collected by data loggers every 5 minutes. Using a digital processing the periodical daily and seasonal variations have been extracted from indoor and outdoor temperature measurements. These variations for indoor and outdoor temperature are considered as excitation and response functions respectively. The periodic outdoor temperature variations could be considered as complex periodic excitation. The Z transformation have been adopted to obtain temperature variations in frequent domain and temperature transfer function for the considered building construction. PB - Materials Research Society of Serbia C3 - Seventeenth Annual Conference YUCOMAT 2015, Herceg Novi, August 31– September 4, 2015. T1 - Determination of the temperature transfer function of building constructions based on measurement data IS - 16 UR - https://hdl.handle.net/21.15107/rcub_grafar_2997 ER -
@conference{ author = "Petojević, Zorana and Mirković, Milica and Jovanović, Željko and Gospavić, Radovan and Todorović, Goran", year = "2015-01-04", abstract = "In this paper a method of determination of transfer function for temperature measured inside and outside residential building in Belgrade is presented. The instantaneous measurements of indoor temperature inside a living room of the second floor flat of the five store building and outdoor temperature at close vicinity of the building facade were made. The external air temperature were also collected from nearby meteorological station few hundred meters apart of the building at the same moments. The measurements have lasted more than three months in period from 22th April till the 2th August. 2014. The data have been collected by data loggers every 5 minutes. Using a digital processing the periodical daily and seasonal variations have been extracted from indoor and outdoor temperature measurements. These variations for indoor and outdoor temperature are considered as excitation and response functions respectively. The periodic outdoor temperature variations could be considered as complex periodic excitation. The Z transformation have been adopted to obtain temperature variations in frequent domain and temperature transfer function for the considered building construction.", publisher = "Materials Research Society of Serbia", journal = "Seventeenth Annual Conference YUCOMAT 2015, Herceg Novi, August 31– September 4, 2015.", title = "Determination of the temperature transfer function of building constructions based on measurement data", number = "16", url = "https://hdl.handle.net/21.15107/rcub_grafar_2997" }
Petojević, Z., Mirković, M., Jovanović, Ž., Gospavić, R.,& Todorović, G.. (2015-01-04). Determination of the temperature transfer function of building constructions based on measurement data. in Seventeenth Annual Conference YUCOMAT 2015, Herceg Novi, August 31– September 4, 2015. Materials Research Society of Serbia.(16). https://hdl.handle.net/21.15107/rcub_grafar_2997
Petojević Z, Mirković M, Jovanović Ž, Gospavić R, Todorović G. Determination of the temperature transfer function of building constructions based on measurement data. in Seventeenth Annual Conference YUCOMAT 2015, Herceg Novi, August 31– September 4, 2015.. 2015;(16). https://hdl.handle.net/21.15107/rcub_grafar_2997 .
Petojević, Zorana, Mirković, Milica, Jovanović, Željko, Gospavić, Radovan, Todorović, Goran, "Determination of the temperature transfer function of building constructions based on measurement data" in Seventeenth Annual Conference YUCOMAT 2015, Herceg Novi, August 31– September 4, 2015., no. 16 (2015-01-04), https://hdl.handle.net/21.15107/rcub_grafar_2997 .