dc.description.abstractSummary: In this paper the experimental results of two-dimensional non-stationary temperature fields of prefabricated ferrocement sandwich panels in fire condition, were presented. In order to determine resistance to fire, the temperature fields of two walls dimensions of 3000 mm × 3000 mm and a thickness of 190 mm made from precast ferrocement sandwich panels, were analyzed. The first panel has been insulated with styro-concrete, and the second with styro-concrete and expanded polystyrene. The panels were exposed to conditions of real fire corresponding to the standard fire curve defined by the standard SRPS EN ISO 834-1. The tests have shown that, due to the detonations that occur when the panels are exposed to fire, these panels have unpredictable behavior.sr
dc.language.isoensr
dc.rightsopenAccesssr
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.source7th International Conference Contemporary Achievements in Civil Engineeringsr
dc.subjectprefabricated ferrocement sandwich elementsr
dc.subjectheat transportsr
dc.subjectfire testsr
dc.titlePrefabricated ferrocement sandwich elements in fire conditionssr
dc.typeconferenceObjectsr
dc.rights.licenseBY-NC-NDsr
dc.citation.epage444
dc.citation.spage437
dc.identifier.doi10.14415/konferencijaGFS2019.038
dc.identifier.fulltexthttp://grafar.grf.bg.ac.rs/bitstream/id/11575/Kijanovic_at_all.pdf