Prikaz osnovnih podataka o dokumentu

dc.creatorIvetić, Damjan
dc.creatorProdanović, Dušan
dc.creatorCvitkovac, Mile
dc.date.accessioned2023-10-06T09:50:14Z
dc.date.available2023-10-06T09:50:14Z
dc.date.issued2017
dc.identifier.urihttps://grafar.grf.bg.ac.rs/handle/123456789/3202
dc.description.abstractFlow measurement in mixed flow conditions is a challenging task, which can be performed only by few techniques like ultrasonic and electromagnetic. Usually despite the flowmeter’s special design, the systematic uncertainty of flow rate remains high. In order to overcome this issue, additional site-specific calibration procedure for flat EM sensors is presented in this paper. Procedure includes both a hydraulic and magnetic field analysis. Concept of its application in the engineering practice example are presented.sr
dc.language.isoensr
dc.publisherIAHR Joint Committee on Urban Drainagesr
dc.rightsopenAccesssr
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.source23rd European Junior Scientists Workshop on Monitoring Urban Drainage Systems, Chichilianne, France, 15-20 May 2017.sr
dc.subjectelectromagnetic flowmeterssr
dc.subjectCFDsr
dc.subjectmixed flowsr
dc.titleUsing CFD and real-magnetic field of EM probes to improve the accuracy of flow measurements in mixed flow conditionssr
dc.typeconferenceObjectsr
dc.rights.licenseBY-NC-NDsr
dc.identifier.fulltexthttp://grafar.grf.bg.ac.rs/bitstream/id/12084/bitstream_12084.pdf
dc.identifier.rcubhttps://hdl.handle.net/21.15107/rcub_grafar_3202
dc.type.versionpublishedVersionsr


Dokumenti

Thumbnail

Ovaj dokument se pojavljuje u sledećim kolekcijama

Prikaz osnovnih podataka o dokumentu