Establishment of the MGI EDM calibration baseline

No Thumbnail
Authors
Božić, Branko
Fan, H.
Milosavljević, Zoran
Article (Published version)
Metadata
Show full item record
Abstract
This paper deals with the estimation of the quality of the baseline for the calibration of distance measurement devices which was established by Serbian Military Geographic Institute for military use. The basic characteristics of the baseline are explained, and a plan for the checking of the baseline quality is proposed. The measurements realised so far can be grouped into two phases. The measurements have been processed, and the estimates of the distances of this length standard have been obtained. The standard deviations of the least squares estimates of the lengths were better than 0.3 mm in each epoch. This precision offers the possibility to check all measurement devices with a minimum uncertainty of the calibrations, of +/-(1 mm + 1 ppm). The stability of the pillars is also analysed. The conventional deformation analysis method was applied to three datasets and the results obtained by evaluating them are shown.
Keywords:
Military Geographic Institute / EDM length standard / EDM calibration baseline / Electronic distance measurement (EDM)
Source:
Survey Review, 2013, 45, 331, 263-268

DOI: 10.1179/1752270611Y.0000000030

ISSN: 0039-6265

WoS: 000321694400004

Scopus: 2-s2.0-84879819355
[ Google Scholar ]
6
4
URI
https://grafar.grf.bg.ac.rs/handle/123456789/529
Collections
  • Radovi istraživača / Researcher's publications
  • Катедра за геодезију и геоинформатику
Institution/Community
GraFar
TY  - JOUR
AU  - Božić, Branko
AU  - Fan, H.
AU  - Milosavljević, Zoran
PY  - 2013
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/529
AB  - This paper deals with the estimation of the quality of the baseline for the calibration of distance measurement devices which was established by Serbian Military Geographic Institute for military use. The basic characteristics of the baseline are explained, and a plan for the checking of the baseline quality is proposed. The measurements realised so far can be grouped into two phases. The measurements have been processed, and the estimates of the distances of this length standard have been obtained. The standard deviations of the least squares estimates of the lengths were better than 0.3 mm in each epoch. This precision offers the possibility to check all measurement devices with a minimum uncertainty of the calibrations, of +/-(1 mm + 1 ppm). The stability of the pillars is also analysed. The conventional deformation analysis method was applied to three datasets and the results obtained by evaluating them are shown.
T2  - Survey Review
T1  - Establishment of the MGI EDM calibration baseline
EP  - 268
IS  - 331
SP  - 263
VL  - 45
DO  - 10.1179/1752270611Y.0000000030
ER  - 
@article{
author = "Božić, Branko and Fan, H. and Milosavljević, Zoran",
year = "2013",
abstract = "This paper deals with the estimation of the quality of the baseline for the calibration of distance measurement devices which was established by Serbian Military Geographic Institute for military use. The basic characteristics of the baseline are explained, and a plan for the checking of the baseline quality is proposed. The measurements realised so far can be grouped into two phases. The measurements have been processed, and the estimates of the distances of this length standard have been obtained. The standard deviations of the least squares estimates of the lengths were better than 0.3 mm in each epoch. This precision offers the possibility to check all measurement devices with a minimum uncertainty of the calibrations, of +/-(1 mm + 1 ppm). The stability of the pillars is also analysed. The conventional deformation analysis method was applied to three datasets and the results obtained by evaluating them are shown.",
journal = "Survey Review",
title = "Establishment of the MGI EDM calibration baseline",
pages = "268-263",
number = "331",
volume = "45",
doi = "10.1179/1752270611Y.0000000030"
}
Božić, B., Fan, H.,& Milosavljević, Z.. (2013). Establishment of the MGI EDM calibration baseline. in Survey Review, 45(331), 263-268.
https://doi.org/10.1179/1752270611Y.0000000030
Božić B, Fan H, Milosavljević Z. Establishment of the MGI EDM calibration baseline. in Survey Review. 2013;45(331):263-268.
doi:10.1179/1752270611Y.0000000030 .
Božić, Branko, Fan, H., Milosavljević, Zoran, "Establishment of the MGI EDM calibration baseline" in Survey Review, 45, no. 331 (2013):263-268,
https://doi.org/10.1179/1752270611Y.0000000030 . .

DSpace software copyright © 2002-2015  DuraSpace
About the GraFar Repository | Send Feedback

OpenAIRERCUB
 

 

All of DSpaceCommunitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About the GraFar Repository | Send Feedback

OpenAIRERCUB