Приказ основних података о документу

Nosivost na smicanje podužnog smičućeg spoja ostvarenog grupama moždanika

dc.creatorSpremić, Milan
dc.creatorMarković, Zlatko
dc.creatorDobrić, Jelena
dc.creatorBuđevac, Dragan
dc.date.accessioned2019-04-19T14:25:54Z
dc.date.available2019-04-19T14:25:54Z
dc.date.issued2016
dc.identifier.issn1451-4117
dc.identifier.urihttps://grafar.grf.bg.ac.rs/handle/123456789/783
dc.description.abstractThe frequently applied solution for shear connection in steel and concrete precast composite struc- tures is the discontinuous shear connection with a headed stud in group arrangement. Application of shear connection with headed studs in group arrangement and calculation of shear resistance for studs group in typical precast composite floor beam is presented. The possibility and feasibility of shear connection construction with headed studs in group arrangement was considered. It is shown that the shear connection in precast composite floor beams can be constructed with a group of four headed studs.en
dc.description.abstractDiskontinualan podužni smičući spoj ostvaren grupisanim moždanicima sa glavom je često korišćeno konstruktivno rešenje smičućeg spoja kod montažnih spregnutih nosača. Prikazana je primena smičućeg spoja ostvarenog grupama moždanika sa glavom i proračun nosivosti na smicanje, na primeru tipičnih montažnih spregnutih podnih nosača međuspratnih konstrukcija. Mogućnost i opravdanost primene konstruktivnog rešenja smičućeg spoja grupama moždanika su razmatrani. Pokazano je da se smičući spoj montažnog spregnutog podnog nosača može izvesti grupom od četiri moždanika.sr
dc.publisherInstitut za istraživanja i projektovanja u privredi, Beograd
dc.rightsopenAccess
dc.sourceJournal of Applied Engineering Science
dc.subjectPrefabricated composite beamsen
dc.subjectShear connectionen
dc.subjectGroup of headed studsen
dc.subjectMontažne spregnute gredesr
dc.subjectSmičući spojsr
dc.subjectGrupe moždanika sa glavomsr
dc.titleShear resistance of longitudinal shear connection with groups of headed studsen
dc.titleNosivost na smicanje podužnog smičućeg spoja ostvarenog grupama moždanikasr
dc.typearticle
dc.rights.licenseARR
dc.citation.epage114
dc.citation.issue1
dc.citation.other14(1): 109-114
dc.citation.rankM51
dc.citation.spage109
dc.citation.volume14
dc.identifier.doi10.5937/jaes14-10471
dc.identifier.fulltexthttps://grafar.grf.bg.ac.rs//bitstream/id/4164/781.pdf
dc.identifier.scopus2-s2.0-84979079604
dc.type.versionpublishedVersion