Abstract
When applying high strength bolts in friction connections, a load-bearing capacity depends on pretension force in the bolts as well as on friction coefficient found on friction surfaces. It is important to get the reliable value of the pretension force, so friction connections often undergo experimental research. In order to use strain gauges, which are inserted into the bolt shank, bolts need to be calibrated before we even use them in experimental research. Research that has been conducted shows a great difference between nominal and experimental strain in bolts, therefore FEA calibration of the bolts had to be carried out. Good results matching were obtained, hence a use of strain gauges was justified even for bolts without a shank.
U slučaju smičućih spojeva s visokovrednim zavrtnjevima s punom silom prednaprezanja, nosivost spoja zavisi kako od intenziteta sile prednaprezanja u visokovrednom zavrtnju, tako i od koeficijenta trenja na tarnim površinama. Veoma je važno odrediti pouzdanu vrednost sile prednaprezanja u visokovrednim zavrtnjevima, pa su tarni spojevi često predmet eksperimentalnih istraživanja. Kako bi se za određivanje intenziteta sile prednaprezanja mogle koristiti merne trake ugrađene u telo zavrtnja, zavrtnjeve je neophodno kalibrisati pre početka njihove primene u eksperimentalnom istraživanju. Sprovedeno istraživanje pokazalo je veliku razliku između nominalnih i eksperimentalno određenih dilatacija zavrtnjeva, zbog čega je sprovedena kalibracija zavrtnjeva numeričkom analizom (primenom metode konačnih elemenata). Dobijeno je dobro poklapanje rezultata, a primena mernih traka kod zavrtnjeva koji imaju navoj celom dužinom tela takođe se pokazala kao opravdana.
Keywords:
high strength bolts / pretension force / calibration / experiment / FEA / longitudinal strain / 'strain plateau' / visokovredni zavrtnjevi / sila prednaprezanja / kalibracija / eksperiment / numerička analiza / podužne dilatacije / 'plato dilatacija'Source:
Građevinski materijali i konstrukcije, 2016, 59, 4, 3-15Publisher:
- Društvo za ispitivanje i istraživanje materijala i konstrukcija Srbije, Beograd
Funding / projects:
Collections
Institution/Community
GraFarTY - JOUR AU - Fric, Nenad AU - Pavlović, Marko AU - Buđevac, Dragan AU - Mišković, Zoran AU - Marković, Zlatko AU - Gluhović, Nina PY - 2016 UR - https://grafar.grf.bg.ac.rs/handle/123456789/785 AB - When applying high strength bolts in friction connections, a load-bearing capacity depends on pretension force in the bolts as well as on friction coefficient found on friction surfaces. It is important to get the reliable value of the pretension force, so friction connections often undergo experimental research. In order to use strain gauges, which are inserted into the bolt shank, bolts need to be calibrated before we even use them in experimental research. Research that has been conducted shows a great difference between nominal and experimental strain in bolts, therefore FEA calibration of the bolts had to be carried out. Good results matching were obtained, hence a use of strain gauges was justified even for bolts without a shank. AB - U slučaju smičućih spojeva s visokovrednim zavrtnjevima s punom silom prednaprezanja, nosivost spoja zavisi kako od intenziteta sile prednaprezanja u visokovrednom zavrtnju, tako i od koeficijenta trenja na tarnim površinama. Veoma je važno odrediti pouzdanu vrednost sile prednaprezanja u visokovrednim zavrtnjevima, pa su tarni spojevi često predmet eksperimentalnih istraživanja. Kako bi se za određivanje intenziteta sile prednaprezanja mogle koristiti merne trake ugrađene u telo zavrtnja, zavrtnjeve je neophodno kalibrisati pre početka njihove primene u eksperimentalnom istraživanju. Sprovedeno istraživanje pokazalo je veliku razliku između nominalnih i eksperimentalno određenih dilatacija zavrtnjeva, zbog čega je sprovedena kalibracija zavrtnjeva numeričkom analizom (primenom metode konačnih elemenata). Dobijeno je dobro poklapanje rezultata, a primena mernih traka kod zavrtnjeva koji imaju navoj celom dužinom tela takođe se pokazala kao opravdana. PB - Društvo za ispitivanje i istraživanje materijala i konstrukcija Srbije, Beograd T2 - Građevinski materijali i konstrukcije T1 - Calibration of the bolt pretension by strain gauges vs. FEA T1 - Eksperimentalna i numerička kalibracija sile prednaprezanja u visokovrednim zavrtnjevima EP - 15 IS - 4 SP - 3 VL - 59 DO - 10.5937/grmk1604003F ER -
@article{ author = "Fric, Nenad and Pavlović, Marko and Buđevac, Dragan and Mišković, Zoran and Marković, Zlatko and Gluhović, Nina", year = "2016", abstract = "When applying high strength bolts in friction connections, a load-bearing capacity depends on pretension force in the bolts as well as on friction coefficient found on friction surfaces. It is important to get the reliable value of the pretension force, so friction connections often undergo experimental research. In order to use strain gauges, which are inserted into the bolt shank, bolts need to be calibrated before we even use them in experimental research. Research that has been conducted shows a great difference between nominal and experimental strain in bolts, therefore FEA calibration of the bolts had to be carried out. Good results matching were obtained, hence a use of strain gauges was justified even for bolts without a shank., U slučaju smičućih spojeva s visokovrednim zavrtnjevima s punom silom prednaprezanja, nosivost spoja zavisi kako od intenziteta sile prednaprezanja u visokovrednom zavrtnju, tako i od koeficijenta trenja na tarnim površinama. Veoma je važno odrediti pouzdanu vrednost sile prednaprezanja u visokovrednim zavrtnjevima, pa su tarni spojevi često predmet eksperimentalnih istraživanja. Kako bi se za određivanje intenziteta sile prednaprezanja mogle koristiti merne trake ugrađene u telo zavrtnja, zavrtnjeve je neophodno kalibrisati pre početka njihove primene u eksperimentalnom istraživanju. Sprovedeno istraživanje pokazalo je veliku razliku između nominalnih i eksperimentalno određenih dilatacija zavrtnjeva, zbog čega je sprovedena kalibracija zavrtnjeva numeričkom analizom (primenom metode konačnih elemenata). Dobijeno je dobro poklapanje rezultata, a primena mernih traka kod zavrtnjeva koji imaju navoj celom dužinom tela takođe se pokazala kao opravdana.", publisher = "Društvo za ispitivanje i istraživanje materijala i konstrukcija Srbije, Beograd", journal = "Građevinski materijali i konstrukcije", title = "Calibration of the bolt pretension by strain gauges vs. FEA, Eksperimentalna i numerička kalibracija sile prednaprezanja u visokovrednim zavrtnjevima", pages = "15-3", number = "4", volume = "59", doi = "10.5937/grmk1604003F" }
Fric, N., Pavlović, M., Buđevac, D., Mišković, Z., Marković, Z.,& Gluhović, N.. (2016). Calibration of the bolt pretension by strain gauges vs. FEA. in Građevinski materijali i konstrukcije Društvo za ispitivanje i istraživanje materijala i konstrukcija Srbije, Beograd., 59(4), 3-15. https://doi.org/10.5937/grmk1604003F
Fric N, Pavlović M, Buđevac D, Mišković Z, Marković Z, Gluhović N. Calibration of the bolt pretension by strain gauges vs. FEA. in Građevinski materijali i konstrukcije. 2016;59(4):3-15. doi:10.5937/grmk1604003F .
Fric, Nenad, Pavlović, Marko, Buđevac, Dragan, Mišković, Zoran, Marković, Zlatko, Gluhović, Nina, "Calibration of the bolt pretension by strain gauges vs. FEA" in Građevinski materijali i konstrukcije, 59, no. 4 (2016):3-15, https://doi.org/10.5937/grmk1604003F . .