Intensity Fiber-Optic Sensor for Structural Health Monitoring Calibrated by Impact Tester
Само за регистроване кориснике
2016
Аутори
Petrović, Miloš
Mihailović, Pedja

Brajović, Ljiljana

Petricević, Slobodan
Živković, Irena
Kojović, Aleksandar
Radojević, Vesna

Чланак у часопису (Објављена верзија)

Метаподаци
Приказ свих података о документуАпстракт
In this paper, the use of intrinsic intensity fiber-optic sensors for structural health monitoring was investigated. Polyethylene-based composite samples with glass mat reinforcement and embedded telecommunication fibers were subjected to impact using high-speed puncture impact tester as a calibration device. Transfer function of the sensor was generated by linking the light intensity modulation depth with the impact force and the impact point to fiber distance. Conditions for transfer function validity were presented. To detect any possible dangerous impact, a net of crossed fibers was proposed and the net spacing for the given material was calculated. Appropriate non-damaging calibration procedure was proposed, as well as the algorithm for locating the impact point. The method for calculating the impact force, the projectile momentum change, and the place of impact was verified by consecutive strikes on the previously calibrated sample. The sensor can also provide information on the ...time of the impact and an alarm signal if the force exceeds the damaging threshold force.
Кључне речи:
Fiber optic sensors / impact testing / structural health monitoring / damage threshold forceИзвор:
Ieee Sensors Journal, 2016, 16, 9, 3047-3053Издавач:
- Institute of Electrical and Electronics Engineers Inc.
Финансирање / пројекти:
- Оптоелектронски нанодимензиони системи - пут ка примени (RS-45003)
- Развој опреме и процеса добијања полимерних композитних материјала са унапред дефинисаним функционалним својствима (RS-34011)
DOI: 10.1109/JSEN.2016.2524045
ISSN: 1530-437X