Shear connection with groups of headed studs

Thumbnail
2017
811.pdf (827.7Kb)
Authors
Spremić, Milan
Marković, Zlatko
Dobrić, Jelena
Veljković, Milan
Buđevac, Dragan
Article (Published version)
Metadata
Show full item record
Abstract
The behaviour and characteristics of the elements of prefabricated composite steel and concrete structures are determined by behaviour of the longitudinal shear connection. Headed studs in groups are most frequently used for forming longitudinal shear connection of prefabricated composite beams. The results of experimental research and advanced numerical models of shear connections, obtained using groups of headed studs, are presented in the paper. When headed studs are arranged in groups, it is recommended to use the headed studs with the height greater than the 4d height prescribed by the Eurocode.
Keywords:
shear connection / groups of studs / prefabricated composite beams
Source:
Građevinar, 2017, 69, 5, 379-386
Publisher:
  • Union of Croatian Civil Engineers and Technicians

DOI: 10.14256/JCE.1701.2016

ISSN: 0350-2465

WoS: 000404781500004

Scopus: 2-s2.0-85021056667
[ Google Scholar ]
2
2
URI
https://grafar.grf.bg.ac.rs/handle/123456789/813
Collections
  • Radovi istraživača / Researcher's publications
  • Катедра за материјале и конструкције
Institution/Community
GraFar
TY  - JOUR
AU  - Spremić, Milan
AU  - Marković, Zlatko
AU  - Dobrić, Jelena
AU  - Veljković, Milan
AU  - Buđevac, Dragan
PY  - 2017
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/813
AB  - The behaviour and characteristics of the elements of prefabricated composite steel and concrete structures are determined by behaviour of the longitudinal shear connection. Headed studs in groups are most frequently used for forming longitudinal shear connection of prefabricated composite beams. The results of experimental research and advanced numerical models of shear connections, obtained using groups of headed studs, are presented in the paper. When headed studs are arranged in groups, it is recommended to use the headed studs with the height greater than the 4d height prescribed by the Eurocode.
PB  - Union of Croatian Civil Engineers and Technicians
T2  - Građevinar
T1  - Shear connection with groups of headed studs
EP  - 386
IS  - 5
SP  - 379
VL  - 69
DO  - 10.14256/JCE.1701.2016
ER  - 
@article{
author = "Spremić, Milan and Marković, Zlatko and Dobrić, Jelena and Veljković, Milan and Buđevac, Dragan",
year = "2017",
abstract = "The behaviour and characteristics of the elements of prefabricated composite steel and concrete structures are determined by behaviour of the longitudinal shear connection. Headed studs in groups are most frequently used for forming longitudinal shear connection of prefabricated composite beams. The results of experimental research and advanced numerical models of shear connections, obtained using groups of headed studs, are presented in the paper. When headed studs are arranged in groups, it is recommended to use the headed studs with the height greater than the 4d height prescribed by the Eurocode.",
publisher = "Union of Croatian Civil Engineers and Technicians",
journal = "Građevinar",
title = "Shear connection with groups of headed studs",
pages = "386-379",
number = "5",
volume = "69",
doi = "10.14256/JCE.1701.2016"
}
Spremić, M., Marković, Z., Dobrić, J., Veljković, M.,& Buđevac, D.. (2017). Shear connection with groups of headed studs. in Građevinar
Union of Croatian Civil Engineers and Technicians., 69(5), 379-386.
https://doi.org/10.14256/JCE.1701.2016
Spremić M, Marković Z, Dobrić J, Veljković M, Buđevac D. Shear connection with groups of headed studs. in Građevinar. 2017;69(5):379-386.
doi:10.14256/JCE.1701.2016 .
Spremić, Milan, Marković, Zlatko, Dobrić, Jelena, Veljković, Milan, Buđevac, Dragan, "Shear connection with groups of headed studs" in Građevinar, 69, no. 5 (2017):379-386,
https://doi.org/10.14256/JCE.1701.2016 . .

DSpace software copyright © 2002-2015  DuraSpace
About the GraFar Repository | Send Feedback

OpenAIRERCUB
 

 

All of DSpaceCommunitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About the GraFar Repository | Send Feedback

OpenAIRERCUB