Shear connection with groups of headed studs
Апстракт
The behaviour and characteristics of the elements of prefabricated composite steel and concrete structures are determined by behaviour of the longitudinal shear connection. Headed studs in groups are most frequently used for forming longitudinal shear connection of prefabricated composite beams. The results of experimental research and advanced numerical models of shear connections, obtained using groups of headed studs, are presented in the paper. When headed studs are arranged in groups, it is recommended to use the headed studs with the height greater than the 4d height prescribed by the Eurocode.
Кључне речи:
shear connection / groups of studs / prefabricated composite beamsИзвор:
Građevinar, 2017, 69, 5, 379-386Издавач:
- Union of Croatian Civil Engineers and Technicians
DOI: 10.14256/JCE.1701.2016
ISSN: 0350-2465
WoS: 000404781500004
Scopus: 2-s2.0-85021056667
Институција/група
GraFarTY - JOUR AU - Spremić, Milan AU - Marković, Zlatko AU - Dobrić, Jelena AU - Veljković, Milan AU - Buđevac, Dragan PY - 2017 UR - https://grafar.grf.bg.ac.rs/handle/123456789/813 AB - The behaviour and characteristics of the elements of prefabricated composite steel and concrete structures are determined by behaviour of the longitudinal shear connection. Headed studs in groups are most frequently used for forming longitudinal shear connection of prefabricated composite beams. The results of experimental research and advanced numerical models of shear connections, obtained using groups of headed studs, are presented in the paper. When headed studs are arranged in groups, it is recommended to use the headed studs with the height greater than the 4d height prescribed by the Eurocode. PB - Union of Croatian Civil Engineers and Technicians T2 - Građevinar T1 - Shear connection with groups of headed studs EP - 386 IS - 5 SP - 379 VL - 69 DO - 10.14256/JCE.1701.2016 ER -
@article{ author = "Spremić, Milan and Marković, Zlatko and Dobrić, Jelena and Veljković, Milan and Buđevac, Dragan", year = "2017", abstract = "The behaviour and characteristics of the elements of prefabricated composite steel and concrete structures are determined by behaviour of the longitudinal shear connection. Headed studs in groups are most frequently used for forming longitudinal shear connection of prefabricated composite beams. The results of experimental research and advanced numerical models of shear connections, obtained using groups of headed studs, are presented in the paper. When headed studs are arranged in groups, it is recommended to use the headed studs with the height greater than the 4d height prescribed by the Eurocode.", publisher = "Union of Croatian Civil Engineers and Technicians", journal = "Građevinar", title = "Shear connection with groups of headed studs", pages = "386-379", number = "5", volume = "69", doi = "10.14256/JCE.1701.2016" }
Spremić, M., Marković, Z., Dobrić, J., Veljković, M.,& Buđevac, D.. (2017). Shear connection with groups of headed studs. in Građevinar Union of Croatian Civil Engineers and Technicians., 69(5), 379-386. https://doi.org/10.14256/JCE.1701.2016
Spremić M, Marković Z, Dobrić J, Veljković M, Buđevac D. Shear connection with groups of headed studs. in Građevinar. 2017;69(5):379-386. doi:10.14256/JCE.1701.2016 .
Spremić, Milan, Marković, Zlatko, Dobrić, Jelena, Veljković, Milan, Buđevac, Dragan, "Shear connection with groups of headed studs" in Građevinar, 69, no. 5 (2017):379-386, https://doi.org/10.14256/JCE.1701.2016 . .