FE validation of the equivalent diameter calculation model for grouped headed studs
Abstract
Existing design codes for steel-concrete composite structures give only general information about the shear connection provided by headed studs in group arrangement. Grouting of the openings in prefabricated concrete slabs, where the grouped headed studs are placed in the deck pockets is alternative to cast-in-place decks to accomplish fast execution of composite structures. This paper considers the possibility to reduce the distance between the studs within the group, bellow the Eurocode limitations. This may lead to increased competitiveness of the prefabricated construction because more studs are placed in the group if negative effectives of smaller distances between studs are limited. The main purpose of this work is to investigate these limits and propose an analytical calculation model for prediction of the shear resistance of grouped stud arrangements in the deck pockets. An advanced FEA model, validated by results of push-out experiments, is used to analyze the shear behavior o...f the grouped stud with smaller distance between them than recommended by EN 1994-1. Calculation model for shear resistance, which is consistent with the existing Eurocode rules, is proposed based on a newly introduced equivalent diameter of the stud group, d(G). The new calculation model is validated by comparison to the results of FE parametric study. The distance between the studs in the longitudinal direction and the number of stud rows and columns in the group are considered as the main variables.
Keywords:
group of headed studs / equivalent diameter / shear connection / finite element methodSource:
Steel and Composite Structures, 2018, 26, 3, 375-386Publisher:
- Techno Press
Funding / projects:
DOI: 10.12989/scs.2018.26.3.375
ISSN: 1229-9367
WoS: 000429329900010
Scopus: 2-s2.0-85049401040
Institution/Community
GraFarTY - JOUR AU - Spremić, Milan AU - Pavlović, Marko AU - Marković, Zlatko AU - Veljković, Milan AU - Buđevac, Dragan PY - 2018 UR - https://grafar.grf.bg.ac.rs/handle/123456789/949 AB - Existing design codes for steel-concrete composite structures give only general information about the shear connection provided by headed studs in group arrangement. Grouting of the openings in prefabricated concrete slabs, where the grouped headed studs are placed in the deck pockets is alternative to cast-in-place decks to accomplish fast execution of composite structures. This paper considers the possibility to reduce the distance between the studs within the group, bellow the Eurocode limitations. This may lead to increased competitiveness of the prefabricated construction because more studs are placed in the group if negative effectives of smaller distances between studs are limited. The main purpose of this work is to investigate these limits and propose an analytical calculation model for prediction of the shear resistance of grouped stud arrangements in the deck pockets. An advanced FEA model, validated by results of push-out experiments, is used to analyze the shear behavior of the grouped stud with smaller distance between them than recommended by EN 1994-1. Calculation model for shear resistance, which is consistent with the existing Eurocode rules, is proposed based on a newly introduced equivalent diameter of the stud group, d(G). The new calculation model is validated by comparison to the results of FE parametric study. The distance between the studs in the longitudinal direction and the number of stud rows and columns in the group are considered as the main variables. PB - Techno Press T2 - Steel and Composite Structures T1 - FE validation of the equivalent diameter calculation model for grouped headed studs EP - 386 IS - 3 SP - 375 VL - 26 DO - 10.12989/scs.2018.26.3.375 ER -
@article{ author = "Spremić, Milan and Pavlović, Marko and Marković, Zlatko and Veljković, Milan and Buđevac, Dragan", year = "2018", abstract = "Existing design codes for steel-concrete composite structures give only general information about the shear connection provided by headed studs in group arrangement. Grouting of the openings in prefabricated concrete slabs, where the grouped headed studs are placed in the deck pockets is alternative to cast-in-place decks to accomplish fast execution of composite structures. This paper considers the possibility to reduce the distance between the studs within the group, bellow the Eurocode limitations. This may lead to increased competitiveness of the prefabricated construction because more studs are placed in the group if negative effectives of smaller distances between studs are limited. The main purpose of this work is to investigate these limits and propose an analytical calculation model for prediction of the shear resistance of grouped stud arrangements in the deck pockets. An advanced FEA model, validated by results of push-out experiments, is used to analyze the shear behavior of the grouped stud with smaller distance between them than recommended by EN 1994-1. Calculation model for shear resistance, which is consistent with the existing Eurocode rules, is proposed based on a newly introduced equivalent diameter of the stud group, d(G). The new calculation model is validated by comparison to the results of FE parametric study. The distance between the studs in the longitudinal direction and the number of stud rows and columns in the group are considered as the main variables.", publisher = "Techno Press", journal = "Steel and Composite Structures", title = "FE validation of the equivalent diameter calculation model for grouped headed studs", pages = "386-375", number = "3", volume = "26", doi = "10.12989/scs.2018.26.3.375" }
Spremić, M., Pavlović, M., Marković, Z., Veljković, M.,& Buđevac, D.. (2018). FE validation of the equivalent diameter calculation model for grouped headed studs. in Steel and Composite Structures Techno Press., 26(3), 375-386. https://doi.org/10.12989/scs.2018.26.3.375
Spremić M, Pavlović M, Marković Z, Veljković M, Buđevac D. FE validation of the equivalent diameter calculation model for grouped headed studs. in Steel and Composite Structures. 2018;26(3):375-386. doi:10.12989/scs.2018.26.3.375 .
Spremić, Milan, Pavlović, Marko, Marković, Zlatko, Veljković, Milan, Buđevac, Dragan, "FE validation of the equivalent diameter calculation model for grouped headed studs" in Steel and Composite Structures, 26, no. 3 (2018):375-386, https://doi.org/10.12989/scs.2018.26.3.375 . .