FE validation of the equivalent diameter calculation model for grouped headed studs

Authorized Users Only
2018
Authors
Spremić, Milan
Pavlović, Marko
Marković, Zlatko
Veljković, Milan
Buđevac, Dragan
Article (Published version)
Metadata
Show full item record
Abstract
Existing design codes for steel-concrete composite structures give only general information about the shear connection provided by headed studs in group arrangement. Grouting of the openings in prefabricated concrete slabs, where the grouped headed studs are placed in the deck pockets is alternative to cast-in-place decks to accomplish fast execution of composite structures. This paper considers the possibility to reduce the distance between the studs within the group, bellow the Eurocode limitations. This may lead to increased competitiveness of the prefabricated construction because more studs are placed in the group if negative effectives of smaller distances between studs are limited. The main purpose of this work is to investigate these limits and propose an analytical calculation model for prediction of the shear resistance of grouped stud arrangements in the deck pockets. An advanced FEA model, validated by results of push-out experiments, is used to analyze the shear behavior o...f the grouped stud with smaller distance between them than recommended by EN 1994-1. Calculation model for shear resistance, which is consistent with the existing Eurocode rules, is proposed based on a newly introduced equivalent diameter of the stud group, d(G). The new calculation model is validated by comparison to the results of FE parametric study. The distance between the studs in the longitudinal direction and the number of stud rows and columns in the group are considered as the main variables.

Keywords:
group of headed studs / equivalent diameter / shear connection / finite element method
Source:
Steel and Composite Structures, 2018, 26, 3, 375-386
Publisher:
  • Techno Press
Funding / projects:
  • Research on condition assessment and improvement methods of civil engineering structures in view of their serviceability, load-bearing capacity, cost effectiveness and maintenance (RS-36048)

DOI: 10.12989/scs.2018.26.3.375

ISSN: 1229-9367

WoS: 000429329900010

Scopus: 2-s2.0-85049401040
[ Google Scholar ]
12
10
URI
https://grafar.grf.bg.ac.rs/handle/123456789/949
Collections
  • Radovi istraživača / Researcher's publications
  • Катедра за материјале и конструкције
Institution/Community
GraFar
TY  - JOUR
AU  - Spremić, Milan
AU  - Pavlović, Marko
AU  - Marković, Zlatko
AU  - Veljković, Milan
AU  - Buđevac, Dragan
PY  - 2018
UR  - https://grafar.grf.bg.ac.rs/handle/123456789/949
AB  - Existing design codes for steel-concrete composite structures give only general information about the shear connection provided by headed studs in group arrangement. Grouting of the openings in prefabricated concrete slabs, where the grouped headed studs are placed in the deck pockets is alternative to cast-in-place decks to accomplish fast execution of composite structures. This paper considers the possibility to reduce the distance between the studs within the group, bellow the Eurocode limitations. This may lead to increased competitiveness of the prefabricated construction because more studs are placed in the group if negative effectives of smaller distances between studs are limited. The main purpose of this work is to investigate these limits and propose an analytical calculation model for prediction of the shear resistance of grouped stud arrangements in the deck pockets. An advanced FEA model, validated by results of push-out experiments, is used to analyze the shear behavior of the grouped stud with smaller distance between them than recommended by EN 1994-1. Calculation model for shear resistance, which is consistent with the existing Eurocode rules, is proposed based on a newly introduced equivalent diameter of the stud group, d(G). The new calculation model is validated by comparison to the results of FE parametric study. The distance between the studs in the longitudinal direction and the number of stud rows and columns in the group are considered as the main variables.
PB  - Techno Press
T2  - Steel and Composite Structures
T1  - FE validation of the equivalent diameter calculation model for grouped headed studs
EP  - 386
IS  - 3
SP  - 375
VL  - 26
DO  - 10.12989/scs.2018.26.3.375
ER  - 
@article{
author = "Spremić, Milan and Pavlović, Marko and Marković, Zlatko and Veljković, Milan and Buđevac, Dragan",
year = "2018",
abstract = "Existing design codes for steel-concrete composite structures give only general information about the shear connection provided by headed studs in group arrangement. Grouting of the openings in prefabricated concrete slabs, where the grouped headed studs are placed in the deck pockets is alternative to cast-in-place decks to accomplish fast execution of composite structures. This paper considers the possibility to reduce the distance between the studs within the group, bellow the Eurocode limitations. This may lead to increased competitiveness of the prefabricated construction because more studs are placed in the group if negative effectives of smaller distances between studs are limited. The main purpose of this work is to investigate these limits and propose an analytical calculation model for prediction of the shear resistance of grouped stud arrangements in the deck pockets. An advanced FEA model, validated by results of push-out experiments, is used to analyze the shear behavior of the grouped stud with smaller distance between them than recommended by EN 1994-1. Calculation model for shear resistance, which is consistent with the existing Eurocode rules, is proposed based on a newly introduced equivalent diameter of the stud group, d(G). The new calculation model is validated by comparison to the results of FE parametric study. The distance between the studs in the longitudinal direction and the number of stud rows and columns in the group are considered as the main variables.",
publisher = "Techno Press",
journal = "Steel and Composite Structures",
title = "FE validation of the equivalent diameter calculation model for grouped headed studs",
pages = "386-375",
number = "3",
volume = "26",
doi = "10.12989/scs.2018.26.3.375"
}
Spremić, M., Pavlović, M., Marković, Z., Veljković, M.,& Buđevac, D.. (2018). FE validation of the equivalent diameter calculation model for grouped headed studs. in Steel and Composite Structures
Techno Press., 26(3), 375-386.
https://doi.org/10.12989/scs.2018.26.3.375
Spremić M, Pavlović M, Marković Z, Veljković M, Buđevac D. FE validation of the equivalent diameter calculation model for grouped headed studs. in Steel and Composite Structures. 2018;26(3):375-386.
doi:10.12989/scs.2018.26.3.375 .
Spremić, Milan, Pavlović, Marko, Marković, Zlatko, Veljković, Milan, Buđevac, Dragan, "FE validation of the equivalent diameter calculation model for grouped headed studs" in Steel and Composite Structures, 26, no. 3 (2018):375-386,
https://doi.org/10.12989/scs.2018.26.3.375 . .

DSpace software copyright © 2002-2015  DuraSpace
About the GraFar Repository | Send Feedback

OpenAIRERCUB
 

 

All of DSpaceCommunitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About the GraFar Repository | Send Feedback

OpenAIRERCUB