Resistance of cold-formed built-up stainless steel columns - Part I: Experiment
Abstract
Nowadays, the codified procedure for design of centrically compressed cold-formed stainless steel (CFSS) builtup members is absent in Europe. Besides, there are no published research information and experimental data in this structural area. This paper focuses on a comprehensive experimental investigation of closely spaced CFSS built-up columns and addresses their flexural buckling capacity about the minor principal axis. Two series with a total of 36 built-up members were assembled, each formed by two discontinuously and directly connected channel chords oriented back-to-back to form an I-section. The chords were press-braked from flat strips of austenitic stainless steel EN 1,4301 as non-slender channel sections. The chords were uniformly interconnected by bolts or by welds. To identify the effects of interconnection spacing on chords' composite action, the overall and chord slenderness ratios were varied. Material properties, cross-section response and initial imperfections were qua...ntified before testing. As a result, the overall flexural buckling without any local-overall interactions was observed as the dominant failure mode. All findings were used in the accompanying paper [1] to establish qualitative data base through numerical simulations of flexural buckling tests. Additionally, a quantitative accuracy assessment of the design methods for carbon steel built-up columns provided in Eurocode and American Specification was reported on the basis of their ability to predict flexural buckling resistances of the tested columns. This enabled numerical parametric studies and proposing design rules for CFSS built-up columns with non-slender sections that capture interconnection shear stiffness, overall and chord slenderness ratio and strain hardening effects.
Keywords:
Stainless steel / Built-up member / Experiment / Compression / Flexural buckling / ResistanceSource:
Journal of Constructional Steel Research, 2018, 145, 552-572Publisher:
- Elsevier Ltd
Funding / projects:
DOI: 10.1016/j.jcsr.2018.02.026
ISSN: 0143-974X
WoS: 000433268900041
Scopus: 2-s2.0-85044722640
Institution/Community
GraFarTY - JOUR AU - Dobrić, Jelena AU - Marković, Zlatko AU - Buđevac, Dragan AU - Spremić, Milan AU - Fric, Nenad PY - 2018 UR - https://grafar.grf.bg.ac.rs/handle/123456789/966 AB - Nowadays, the codified procedure for design of centrically compressed cold-formed stainless steel (CFSS) builtup members is absent in Europe. Besides, there are no published research information and experimental data in this structural area. This paper focuses on a comprehensive experimental investigation of closely spaced CFSS built-up columns and addresses their flexural buckling capacity about the minor principal axis. Two series with a total of 36 built-up members were assembled, each formed by two discontinuously and directly connected channel chords oriented back-to-back to form an I-section. The chords were press-braked from flat strips of austenitic stainless steel EN 1,4301 as non-slender channel sections. The chords were uniformly interconnected by bolts or by welds. To identify the effects of interconnection spacing on chords' composite action, the overall and chord slenderness ratios were varied. Material properties, cross-section response and initial imperfections were quantified before testing. As a result, the overall flexural buckling without any local-overall interactions was observed as the dominant failure mode. All findings were used in the accompanying paper [1] to establish qualitative data base through numerical simulations of flexural buckling tests. Additionally, a quantitative accuracy assessment of the design methods for carbon steel built-up columns provided in Eurocode and American Specification was reported on the basis of their ability to predict flexural buckling resistances of the tested columns. This enabled numerical parametric studies and proposing design rules for CFSS built-up columns with non-slender sections that capture interconnection shear stiffness, overall and chord slenderness ratio and strain hardening effects. PB - Elsevier Ltd T2 - Journal of Constructional Steel Research T1 - Resistance of cold-formed built-up stainless steel columns - Part I: Experiment EP - 572 SP - 552 VL - 145 DO - 10.1016/j.jcsr.2018.02.026 ER -
@article{ author = "Dobrić, Jelena and Marković, Zlatko and Buđevac, Dragan and Spremić, Milan and Fric, Nenad", year = "2018", abstract = "Nowadays, the codified procedure for design of centrically compressed cold-formed stainless steel (CFSS) builtup members is absent in Europe. Besides, there are no published research information and experimental data in this structural area. This paper focuses on a comprehensive experimental investigation of closely spaced CFSS built-up columns and addresses their flexural buckling capacity about the minor principal axis. Two series with a total of 36 built-up members were assembled, each formed by two discontinuously and directly connected channel chords oriented back-to-back to form an I-section. The chords were press-braked from flat strips of austenitic stainless steel EN 1,4301 as non-slender channel sections. The chords were uniformly interconnected by bolts or by welds. To identify the effects of interconnection spacing on chords' composite action, the overall and chord slenderness ratios were varied. Material properties, cross-section response and initial imperfections were quantified before testing. As a result, the overall flexural buckling without any local-overall interactions was observed as the dominant failure mode. All findings were used in the accompanying paper [1] to establish qualitative data base through numerical simulations of flexural buckling tests. Additionally, a quantitative accuracy assessment of the design methods for carbon steel built-up columns provided in Eurocode and American Specification was reported on the basis of their ability to predict flexural buckling resistances of the tested columns. This enabled numerical parametric studies and proposing design rules for CFSS built-up columns with non-slender sections that capture interconnection shear stiffness, overall and chord slenderness ratio and strain hardening effects.", publisher = "Elsevier Ltd", journal = "Journal of Constructional Steel Research", title = "Resistance of cold-formed built-up stainless steel columns - Part I: Experiment", pages = "572-552", volume = "145", doi = "10.1016/j.jcsr.2018.02.026" }
Dobrić, J., Marković, Z., Buđevac, D., Spremić, M.,& Fric, N.. (2018). Resistance of cold-formed built-up stainless steel columns - Part I: Experiment. in Journal of Constructional Steel Research Elsevier Ltd., 145, 552-572. https://doi.org/10.1016/j.jcsr.2018.02.026
Dobrić J, Marković Z, Buđevac D, Spremić M, Fric N. Resistance of cold-formed built-up stainless steel columns - Part I: Experiment. in Journal of Constructional Steel Research. 2018;145:552-572. doi:10.1016/j.jcsr.2018.02.026 .
Dobrić, Jelena, Marković, Zlatko, Buđevac, Dragan, Spremić, Milan, Fric, Nenad, "Resistance of cold-formed built-up stainless steel columns - Part I: Experiment" in Journal of Constructional Steel Research, 145 (2018):552-572, https://doi.org/10.1016/j.jcsr.2018.02.026 . .