The effect of land use schematization on result of surface runoff modeling with the example of Miljakovac catchments / Analiza uticaja nepoznavanja namene površina na rezultate simulacije modela kišnog oticaja na primeru Miljakovac
(Udruženje za tehnologiju vode i sanitarno inžinjerstvo, Beograd, 2005)
Experimental catchments Miljakovac has been used in 1980-es for field studies of rainfall-runoff processes. The most accurate analysis of flow in storm sewer systems can be achieved when there is a land use map defined in ...
Hydraulic model study of turbulent flow measurement in sewer pipes conjunction / Hidraulička modelska ispitivanja merenja protoka na spoju kolektora sa silovitim tečenjem
(Udruženje za tehnologiju vode i sanitarno inžinjerstvo, Beograd, 2009)
This paper presents capabilities and benefits of use of physical models for flow analysis in large sewer pipes and conjoining objects. A group of objects pertaining to the Belgrade Sewer System is modeled and results are ...
Interaktivni pristup u primeni strategije razvoja vodovodnog sistema Panceva
(Voda i sanitarna tehnika, 2016)
Measurements on lake Zavoj for the purpose of water quality management and control / Merenja na jezeru Zavoj u cilju praćenja i upravljanja kvalitetom vode
(Udruženje za tehnologiju vode i sanitarno inžinjerstvo, Beograd, 2008)
Eutrofication represents a serious limiting factor in a various utilization of water from reservoirs. In order to recognize driving processes in a lake 'Zavoj', near Pirot, a comprehensive measurement campaign has been ...
Sewer outlets impact on Topciderka river water quality / Uticaj kanalizacionih ispusta na kvalitet vode Topčiderske reke
(Udruženje za tehnologiju vode i sanitarno inžinjerstvo, Beograd, 2007)
In this paper impact of sewer outlets on water quality of Topciderka river has been presented. Water quality model has been developed as a joint of two standard software packages: HecRAS and QUAL2E. HecRAS, as supporting ...
Design of supplementary water tank 'Julino brdo' - Belgrade / Kompenzacioni rezervoar 'Julino brdo' - Beograd
(Udruženje za tehnologiju vode i sanitarno inžinjerstvo, Beograd, 2004)
The supplementary water tank “Julino Brdo”- Belgrade has been planed in order to provide water supply of the very centre of Belgrade during the accident situations. In the first phase two of the three water tanks are going ...
Instability analysis of the air-water flow in porous medium / Analiza pojave nestabilnosti kod dvofaznog strujanja u poroznoj sredini
(Udruženje za tehnologiju vode i sanitarno inžinjerstvo, Beograd, 2010)
The paper deals with modeling of two phase (water-air) flow in coarse porous medium, where, after reaching some air velocity, instability of the flow occurs. Firstly, a linear stability analysis has been conducted for ...
Water mixing in reservoir and water age in the distribution network modelling / Modeliranje mešanja vode u rezervoaru i starosti u distributivnoj mreži
(Udruženje za tehnologiju vode i sanitarno inžinjerstvo, Beograd, 2014)
The main role of reservoirs is to store the water for periods when consumption is higher then water production, thus increasing the reliability of system. However, the water storage can also lead to water aging, and its ...
Water leakage management in water supply systems / Upravljanja gubicima u vodovodnim sistemima
(Udruženje za tehnologiju vode i sanitarno inžinjerstvo, Beograd, 2008)
Leakage reduction and reduction of un-rationalized water usage is the basis for the effective operation of Water Utility. Current practice of reactive (or passive) leakage reduction should be replaced by proactive search ...
Introduction of rain gauges into monitoring of sewer systems: Experiences in choosing, testing and installing the measuring equipment / Uvođenje kišomera u sistem praćenja rada kanalizacionog sistema - iskustva iz faze nabavke, provere i postavljanja
(Udruženje za tehnologiju vode i sanitarno inžinjerstvo, Beograd, 2005)
Improvement of the Belgrade sewer system performance, necessitated by increasing urbanization, calls for more precise assessment of water balance in the system. In this respect, three rain gauge stations are established ...