Претраживање
Приказ резултата 1-10 од 18
Hydraulic design of morning glory spillway with a deflector upstream of the vertical bend / Određivanje dimenzija šahtnog preliva empirijskim jednačinama
(Jugoslovensko društvo za odvodnjavanje i navodnjavanje, Beograd, 2012)
Hydraulic design of shaft spillways (morning-glory spillways) with flow deflector before the vertical bend is considered. Based on the physical hydraulic model investigations of several structures and available experience ...
Contracting-expanding chute numerical modelling / Numeričko modeliranje brzotoka pri promeni pravca zida kanala
(Jugoslovensko društvo za odvodnjavanje i navodnjavanje, Beograd, 2005)
Two-dimensional (2D) open-channel flow models for contracting and expanding chutes are developed. TVD McCormack and TVD MUSCL method have been used to facilitate an easy-to-use code. The performances of the numerical models ...
Stresses in the upstream cutoff zone of concrete gravity dams / Naponsko stanje u zoni uzvodnog zuba gravitacione betonske brane
(Jugoslovensko društvo za odvodnjavanje i navodnjavanje, Beograd, 2011)
Upstream cutoff in the concrete gravity dam foundation is introduced as a general stability measure in the beginning of the 20-th century. It become widely accepted in design practice in the late 50-ties. Nevertheless, ...
Numerical modeling of a steep chute with curvature in plane / Numeričko modeliranje brzotoka u krivini
(Jugoslovensko društvo za odvodnjavanje i navodnjavanje, Beograd, 2005)
Two-dimensional (2D) open-channel flow models for a steep chute with curvature in plane are developed. TVD McCormack and TVD MUSCL method have been used to facilitate an easy-to-use code. The performances of the numerical ...
Estimating the capacity of double side-channel spillways / Procena propusne moći dvostrukog bočnog preliva
(Jugoslovensko društvo za odvodnjavanje i navodnjavanje, Beograd, 2009)
A double side-channel spillway consists of two spillways, with channels joining into a common single branch, noting that for some specific site conditions such arrangements may suit better than the conventional one-side-channel ...
Rešavanje jednačina kretanja fluida metodom zasnovanom na praćenju fluidnih delića (SPH metoda) / SPH method
(Srpsko društvo za odvodnjavanje i navodnjavanje, 2014)
U ovom radu se opisuje numerička metoda za rešavanje jednačina kretanja fluida zasnovana na praćenju fluidnih delića, koja se na engleskom jeziku naziva Smoothed Particle Hydrodynamics (skraćeno SPH). Predstavljene su ...
Possible use of hydropower potential of cooling water at the thermal power plant / Mogućnost korišćenja hidroenergetskog potencijala vode za hlađenje termoelektrana
(Jugoslovensko društvo za odvodnjavanje i navodnjavanje, Beograd, 2011)
Possibility of using hydropower potential of cooling water at the thermal power plant with open cooling system is presented in the paper. Cooling water flows gravitationally to the recipient - the river. In the periods of ...
Numerical modeling of supercritical flow in closed conduit bend / Numeričko modeliranje burnog tečenja u krivini zatvorenog provodnika
(Jugoslovensko društvo za odvodnjavanje i navodnjavanje, Beograd, 2015)
Numerical modeling of supercritical flow in closed conduit bend is a continuation of the scale model experiments. The main goal of application of numerical model is to extend the range of investigation and to simulate ...
Stepenasti preliv sa odbojnom gredom
(Jugoslovensko društvo za odvodnjavanje i navodnjavanje, Beograd, 2010)
The stepped spillway with baffle as an overflow section of the small retention dams is presented. This is an original structure, designed as a stepped spillway, with bottom outlets and the modified USBR VI stilling basin ...
Structural analysis of Jelezovac dam stepped spillway with baffle / Statička analiza stepenastog preliva sa odbojnom gredom na pregradi Jelezovac
(Jugoslovensko društvo za odvodnjavanje i navodnjavanje, Beograd, 2010)
The concrete gravity dam spillway on the Jelezovac stream is presented. The overflow section of the dam is an original structure, designed as a stepped spillway, with bottom outlets and the modified USBR VI stilling basin ...