Fatigue damage detection in composite rods using fiber optic intensity based sensors
(Trans Tech Publications Ltd, 2004)
An application of the embedded intensity based fiber optic sensors (FOS) for fatigue damage detection in cantilevered composite rods is presented. During the fatigue test with constant amplitude of oscillations, the ...
Effects of full-height nonstructural partitions on modal properties of two nominally identical building floors
(Canadian Journal of Civil Engineering, 2009)
This paper presents a combined experimental and numerical investigation of the modal properties of two fullscale and nominally identical steel-concrete composite floors. The floors were one above the other in the same fully ...