Претраживање
Приказ резултата 1-10 од 12
Design of class 4 cross section in axial compression according to EUROCODE 3
(MASE 13. International symposium 2009, 14th – 17th October 2009. Ohrid, Macedonia, Skopje 2009, Knjiga 1, 2009)
In this paper theoretic basis of design of class 4 cross section in axial compression according to EN1993-1-5 is given. Design procedure is given as an flow chart and ilustrated with an worked example. Plate buckling is ...
Assessment of the position and dimensions of the ski-jump scour-hole / Procena položaja i dimenzija erozione jame ski odskoka
(Jugoslovensko društvo za odvodnjavanje i navodnjavanje, Beograd, 2006)
This paper is concerned with the ski-jump design, mainly for the large overflow dams. Although the vast scope of literature on this subject exists, there is still a need to compile, elaborate and upgrade available knowledge. ...
Uporedna analiza proračuna ekscentrično pritisnutih elemenata prema Evrokodu 3 i JUS-u
(Simpozijum DGKS 2008, 24-26 septembar 2008, Zlatibor, 2008)
Evrokod 3 daje dva ravnopravna postupka proračuna interakcionih koeficijenata za proračun ekscentrično pritisnutih elemenata konstantnog jednodelnog poprečnog preseka. U ovom radu je data uporedna analiza rezultata proračuna ...
Primer primene akustičke izolacije u čeličnoj konstrukciji sinemapleksa ''STER'' u Beogradu / Primer primene akustičke izolacije u čeličnoj konstrukciji sinemapleksa ''STER'' u Beogradu
(Internacionalni naučno-stručni skup Građevinarstvo - nauka i praksa 2008, 03-07. mart 2008, Žabljak, Podgorica 2008, Knjiga 1, 2008)
Modern public buildings, such as multiplex cinemas, along with application of state of the art sound effects brings high acoustic isolation demands. Cinemas are often a part of building complexes such as shopping malls ...
EC2: Design of reinforced concrete for shear
(MASE-Macedonian Association of Structural Engineers, 2003)
An overall comparison of the shear design according to EC2 (prEN 1992-1-1, July 2002.) with Yugoslav PBAB 87 is presented. Required amount of the reinforcing steel is analyzed through several levels of stressing. Changes ...
Estimating the capacity of double side-channel spillways / Procena propusne moći dvostrukog bočnog preliva
(Jugoslovensko društvo za odvodnjavanje i navodnjavanje, Beograd, 2009)
A double side-channel spillway consists of two spillways, with channels joining into a common single branch, noting that for some specific site conditions such arrangements may suit better than the conventional one-side-channel ...
Design and construction of DELTA CITY shopping mail concrete structure in Belgrade
(Tailor Made Concrete Structures: New Solutions for Our Society, 2008)
Long-term behavior of precast concrete girder with cast in place deck and diaphragm
(Department of Civil Engineering - Faculty of Tecnical Science, Novi Sad, 2009)
Composite precast-cast in place bridge girders made continuous for live load are very
popular solution for bridges of small to medium spans. In domain of service state of stresses,
material nonlinearity of concrete ...
Nonlinear finite element anal ysis of punching strength of lift slabs at edge columns
(Publisbing Company of Budapest University of Tecbnology and Economics, 2005)
The experimental investigation of punching shear strength of post-tensioned lift slab-edge column connection was simulated using the DIANA Finite Element System. One of the tested specimens was modeled by solid elements ...
Design and construction of DELTA CITY shopping mall concrete structure in Belgrade
(CRC Press/Balkema, 2008)
The structure of DELTA CITY shopping mall in Belgrade consists oftwo separated structures: the structure of the mall and the structure of the multi-story open garage. The overall dimensions of the irregular layout of the ...