Pretraživanje
Prikaz rezultata 1-3 od 3
Improvement of the flow measuring methodology with the flat electromagnetic velocity probes / Unapređenje metodologije merenja protoka pomoću ravnih elektromagnetnih senzora brzine
(Jugoslovensko društvo za odvodnjavanje i navodnjavanje, Beograd, 2017)
One of the commonly used approaches, for the flow measurements in open chanel hydraulic systems, is to measure one depth and use the stable Q-H relationship to compute the flow rate. If this method is inappropriate, the ...
Improved flow measurement using EM flat probes in mixed flow conditions
(ICUD 2017, 2017)
One of the commonly used approaches, for the flow measurements in sewer systems, are velocity-area methods. Although, it is reported that the velocity sensors operate with high uncertainty, the popularity of these methods ...
Using CFD and real-magnetic field of EM probes to improve the accuracy of flow measurements in mixed flow conditions
(IAHR Joint Committee on Urban Drainage, 2017)