Sewer outlets impact on Topciderka river water quality / Uticaj kanalizacionih ispusta na kvalitet vode Topčiderske reke
(Udruženje za tehnologiju vode i sanitarno inžinjerstvo, Beograd, 2007)
In this paper impact of sewer outlets on water quality of Topciderka river has been presented. Water quality model has been developed as a joint of two standard software packages: HecRAS and QUAL2E. HecRAS, as supporting ...
Design of supplementary water tank 'Julino brdo' - Belgrade / Kompenzacioni rezervoar 'Julino brdo' - Beograd
(Udruženje za tehnologiju vode i sanitarno inžinjerstvo, Beograd, 2004)
The supplementary water tank “Julino Brdo”- Belgrade has been planed in order to provide water supply of the very centre of Belgrade during the accident situations. In the first phase two of the three water tanks are going ...
The Belgrade sewage water quality parameters database development / Razvoj baze podataka parametara kvaliteta vode u Beogradskoj kanalizaciji
(Udruženje za tehnologiju vode i sanitarno inžinjerstvo, Beograd, 2008)
In this paper the relational database development that represent the advanced solution for the Belgrade sewage water quality parameters warehousing is presented. Database is adjusted to the specific needs of the data ...
Analytical optimization method for water supply systems modeling / Analitička optimizaciona metoda u modeliranju vodovodnih sistema
(Udruženje za tehnologiju vode i sanitarno inžinjerstvo, Beograd, 2007)
The consequence of an uncertainty of water supply systems models’ parameters is the discrepancy between simulation results and measurement data. The best values of parameters that can be obtained from available measurement ...
Water losses reduction by managing operational pressure / Upravljanje radnim pritiskom u cilju smanjenja gubitaka
(Udruženje za tehnologiju vode i sanitarno inžinjerstvo, Beograd, 2007)
Managing operational pressure is essential for effective reduction of water losses, so system operation is directed towards its maximum reduction with fulfilling the demand of each customer. With this objective, the variable ...
The effect of land use schematization on result of surface runoff modeling with the example of Miljakovac catchments / Analiza uticaja nepoznavanja namene površina na rezultate simulacije modela kišnog oticaja na primeru Miljakovac
(Udruženje za tehnologiju vode i sanitarno inžinjerstvo, Beograd, 2005)
Experimental catchments Miljakovac has been used in 1980-es for field studies of rainfall-runoff processes. The most accurate analysis of flow in storm sewer systems can be achieved when there is a land use map defined in ...
Measurements in Belgrade sewer system / Merenja na Beogradskom kanalizacionom sistemu
(Udruženje za tehnologiju vode i sanitarno inžinjerstvo, Beograd, 2009)
The installation of monitoring system at 8 sewer outlets of Belgrade Sewer System has started during 2007. In this paper the extension of that process is presented, where 5 new monitoring sites were equipped and new ...
Hydraulic model study of turbulent flow measurement in sewer pipes conjunction / Hidraulička modelska ispitivanja merenja protoka na spoju kolektora sa silovitim tečenjem
(Udruženje za tehnologiju vode i sanitarno inžinjerstvo, Beograd, 2009)
This paper presents capabilities and benefits of use of physical models for flow analysis in large sewer pipes and conjoining objects. A group of objects pertaining to the Belgrade Sewer System is modeled and results are ...
Ultrasonic flow measurement method: Working principles and use in water distribution and sewer systems / Ultrazvučna merila protoka u sistemima vodovoda i kanalizacije
(Udruženje za tehnologiju vode i sanitarno inžinjerstvo, Beograd, 2007)
Flow metering in Water Supply and Sewer Systems (WSSS) is the essential need Technical reason are the water balance control and the operational management. In the scope of inevitable privatizations (in Serbian environment) ...
Projektovanje i upravljanje sistemima za kanalisanje kišnih voda u gradovima
(Udruženje za tehnologiju vode i sanitarno inžinjerstvo, Beograd, 2000)
U radu je ukratko prikazan sadržaj radova koji su potrebni za uspostavljanje koncepta za sistematsko upravljanje kišnim oticanjem u gradskim uslovima. Posebno je naglašeno da u Jugoslaviji ne postoji ni polazna osnova za ...