Претраживање
Приказ резултата 451-460 од 475
Environmental assessment of green concretes for structural use
(Elsevier Ltd, 2017)
This paper presents a comparative environmental assessment of several different green concrete mixes for structural use. Four green concrete mixes were compared with a conventional concrete mix: recycled aggregate concrete ...
Long-term behaviour of reinforced beams made with natural or recycled aggregate concrete and high-volume fly ash concrete
(Elsevier Ltd, 2018)
Six simply supported reinforced concrete beams were tested under sustained loads for 450 days. The beams were made from natural aggregate concrete (NAC), recycled aggregate concrete (RAC) and high volume fly ash concrete ...
Hydro energy potential of cooling water at the thermal power plant
(Elsevier Ltd, 2011)
The hydro energy of the gravity water flow from the coal-fired thermal power plant units to the river in an open cooling system of turbine condensers is determined. On the basis of statistical data for a long time period, ...
Recycled concrete as aggregate for structural concrete production
(MDPI AG, 2010)
A comparative analysis of the experimental results of the properties of fresh and hardened concrete with different replacement ratios of natural with recycled coarse aggregate is presented in the paper. Recycled aggregate ...
Comparative studies of the life cycle analysis between conventional and recycled aggregate concrete
(Woodhead Publishing, 2018)
Experimental testing of reinforced end-notched glulam beams / Eksperimentalno ispitivanje ojačanih lepljeno lameliranih drvenih nosača sa redukovanom visinom preseka
(Društvo za ispitivanje i istraživanje materijala i konstrukcija Srbije, Beograd, 2018)
Notches made at the ends of timber beams significantly decrease load carrying capacity of a structural member. This paper presents an experimental research on bending behaviour of end-notched glulam beams, with and without ...
Vibrational behaviour of timber floors
(11th World Conference on Timber Engineering 2010, WCTE 2010, 2010)
A complete design methodology for timber floors must address the problem of annoying vibration caused by the occupants themselves. Proper controlling relies on good understanding nature of floor vibrations induced by human ...
Sanacija oštećenja lepljenih lameliranih drvenih greda sa redukovanom visinom preseka kod oslonaca pomoću GFRP šipki
(Savez građevinskih inženjera Srbije, 2020)
U radu je predstavljeno eksperimentalno ispitivanje mogućnosti sanacije oštećenih lepljenih lamliranih drvenih greda sa redukovanom visinom preseka kod oslonaca pomoću šipki na bazi polimera ojačanih staklenim vlaknima ...
Calibration of the high strenght bolts for measuring of the pretension force
(International Conference on ADVANCES IN STEEL STRUCTURES, Lisbon, Portugal, July 22-24, 2015., 2015)
When analysing slip resistance connections, which are commonly used in-situ assemblied joints of structures dominantly loaded by cyclic loading, for example in bridges, telecommunication towers, towers for wind turbines, ...
Wind towers - design of flange ring connection
(Proceedings of the 14th international symposium of MASE, 2011)
Today, wind power is second largest available renewable resource of energy, with 870 TW (terawatts). Large wind farms, with hundreds of wind towers are big opportunity for steel production industry. Designers and manufacturers ...