Search
Now showing items 1-10 of 438
Temperature variation of "Bajina Bašta" dam between 1995-2015 / Temperature u brani i akumulaciji "Bajina Bašta" u periodu 1995-2015
(Građevinski fakultet, Subotica, 2016)
In this paper, the data for the observed temperatures (of the air, body of the dam and water in the reservoir), for "Bajina Bašta" Dam, during the 20-years period, are presented. The data were used to predict the unsteady ...
Vehicle speed influence on the dynamic amplification factor of bridges
(Faculty of Civil Engineering Subotica University of Novi Sad, 2019)
The paper presents an analysis of the influence of vehicle speed movement
along bridge on dynamic amplification factor for the case of simply supported, continuous
and clamped beam structural system. The analysis was ...
Flood control of tailings-dam reservoirs / Problemi evakuacije velikih voda iz jalovišnih akumulacija
(Jugoslovensko društvo za odvodnjavanje i navodnjavanje, Beograd, 2017)
This paper analyzes the problems of flood control for the tailings-dams reservoirs, having in mind the significant rise of the flow and volume of observed flood waves, and increasingly stringent criteria for safety of high ...
Resistace of bolted shear connectors in prefabricated steel – concrete composite decks
(Društvo građevinskih konstruktera Srbije, Beograd, 2016)
Possibilities of building structures using exposed concrete factors of influence
(Macedonian Association of Structural Engineers, Skopje, 2015)
Resistance of cold-formed built-up stainless steel columns - Part II: Numerical simulation
(Elsevier Ltd, 2018)
In parallel with an experimental investigation of the flexural buckling behaviour of built-up stainless steel columns presented in the accompanying paper (Dobric et al., submitted for publication), a detailed Finite Element ...
FE validation of the equivalent diameter calculation model for grouped headed studs
(Techno Press, 2018)
Existing design codes for steel-concrete composite structures give only general information about the shear connection provided by headed studs in group arrangement. Grouting of the openings in prefabricated concrete slabs, ...
Computation of Thermal-Stresses and Contraction Joint Distance of RCC Dams
(Journal of Thermal Stresses, 2013)
A new approach in 3D numerical modeling for unsteady phased thermal-stress analysis of a massive concrete hydraulic structure is presented. The temperature field is computed first, providing a drive for the unsteady, ...
Resistance of cold-formed built-up stainless steel columns - Part I: Experiment
(Elsevier Ltd, 2018)
Nowadays, the codified procedure for design of centrically compressed cold-formed stainless steel (CFSS) builtup members is absent in Europe. Besides, there are no published research information and experimental data in ...
Eurocode 6: Masonry structures / Evrokod 6 - zidane konstrukcije
(Udruženje inženjera građevinarstva, geotehnike, arhitekture i urbanista "Izgradnja", Beograd, 2010)
A general concept of Eurocode 6 - Design of Masonry Structures, as European standard which deals with basic problems of masonry structures, is presented in this paper. Special attention is dedicated to Chapter 3 of the ...